Direct measurement of intra-abdominal pressure with a solid microtranducer

被引:22
|
作者
Pracca F.F. [1 ]
Biestro A.A. [1 ]
Moraes L. [1 ]
Puppo C.B. [1 ]
Calvo S.M. [1 ]
Gorrasi J. [1 ]
Cancela M. [1 ]
机构
[1] Department of Intensive Care Medicine, Hospital de Clinicas, Montevideo 11600, Avda Italia s/n
关键词
Abdominal compartment syndrome; Codman microsensor; Intra-abdominal pressure; Intravesical pressure; Pressure monitor;
D O I
10.1007/s10877-007-9071-2
中图分类号
学科分类号
摘要
Objective: To describe a direct intra-abdominal pressure (IAP) measurement technique using a solid microsensor comparing its values with the ones simultaneously obtained by means of Kron's technique. Comparative study between two different methods to measure intra-abdominal pressure in a multidisciplinary intensive care unit of a university hospital. Methods: In 11 critical patients considered irreversibly ill, IAP was simultaneously measured via Kron's technique (IAPK) and by direct measure (IAPC) through an abdominal tap with a Codman microsensor, inserted through it. Several measurements were obtained at different PEEP levels (0, 10 and 20 cm of H20) and bed inclination (0°, 40° and 60°). Results: 92 simultaneous measurements of IAPK and IAPC were made. The difference between both measurements (mean ±SD) were: 0.286 ± 0.938 mmHg. The correlation coefficient was r = 0.98. Bland-Altman plot showed a narrow distribution: 95% of the differences were between 1.87 mmHg of each averaged value. No complications with IAPC measurements were found. Conclusions: Direct IAP measurement with a Codman microsensor allows continuous monitoring without urinary tract manipulation, is simple to use and to calibrate, minimally invasive and appropriate for patients at risk to develop abdominal compartmental syndrome. Due to its cost it should be reserved for selected critical patients where standard techniques are contraindicated or can be inaccurate. © Springer Science+Business Media, Inc. 2007.
引用
收藏
页码:167 / 170
页数:3
相关论文
共 50 条
  • [41] The Value of Intra-abdominal Pressure Measurement in Patients with Acute Abdomen
    Ibis, Cem
    Altan, Aydin
    ASIAN JOURNAL OF SURGERY, 2009, 32 (01) : 33 - 38
  • [42] Validation of the urine column measurement as an estimation of the intra-abdominal pressure
    van der Steeg, Herjan
    van Akkeren, Jesse P.
    Houterman, Saskia
    Roumen, Rudi M. H.
    INTENSIVE CARE MEDICINE, 2009, 35 (05) : 914 - 918
  • [43] Validation of the urine column measurement as an estimation of the intra-abdominal pressure
    Herjan van der Steeg
    Jesse P. van Akkeren
    Saskia Houterman
    Rudi M. H. Roumen
    Intensive Care Medicine, 2009, 35 : 914 - 918
  • [44] In vivo measurement of the effect of intra-abdominal pressure on the human spine
    Hodges, PW
    Cresswell, AG
    Daggfeldt, K
    Thorstensson, A
    JOURNAL OF BIOMECHANICS, 2001, 34 (03) : 347 - 353
  • [45] Evaluation of transvesical intra-abdominal pressure measurement in hospitalized dogs
    Fetner, Melissa
    Prittie, Jennifer
    JOURNAL OF VETERINARY EMERGENCY AND CRITICAL CARE, 2012, 22 (02) : 230 - 238
  • [46] Problematik der intraabdominellen DruckmessungProblematic of intra-abdominal pressure measurement
    P. Neumann
    Der Anaesthesist, 2009, 58 : 527 - 531
  • [47] A comparison of infusion volumes in the measurement of intra-abdominal pressure.
    Kimball, EJ
    Baraghoshi, GK
    Morris, SE
    Hansen, HJ
    Mone, MC
    Barton, RG
    CRITICAL CARE MEDICINE, 2005, 33 (12) : A37 - A37
  • [48] Measurement of the intra-abdominal pressure in clinical daily practice in Germany
    Otto, J.
    Schachtrupp, A.
    Schumacher, O.
    Binneboesel, M.
    Jansen, M.
    ACTA CLINICA BELGICA, 2007, 62 : 293 - 293
  • [49] Intra-abdominal pressure in dogs
    Goncalves, Ronald Paiva M.
    Wouk, Antonio Felipe P. F.
    Mira, Anabella
    PESQUISA VETERINARIA BRASILEIRA, 2011, 31 (09): : 812 - 816
  • [50] CHANGES IN INTRA-ABDOMINAL PRESSURE
    LIGHT, HG
    ROUTLEDGE, JA
    SURGERY, 1964, 56 (04) : 747 - 749