The Value of Intra-abdominal Pressure Measurement in Patients with Acute Abdomen

被引:1
|
作者
Ibis, Cem [1 ]
Altan, Aydin [1 ]
机构
[1] Trakya Univ, Fac Med, Dept Gen Surg, Edirne, Turkey
关键词
acute abdomen; peritonitis; ABDOMINAL COMPARTMENT SYNDROME;
D O I
10.1016/S1015-9584(09)60006-3
中图分类号
R61 [外科手术学];
学科分类号
摘要
AIM: To find out the potential benefit of bladder pressure (BP) measurement as a diagnostic tool for acute abdomen. BACKGROUND: Acute abdomen is one of the most important clinical entities among general Surgical clinics. The diagnosis can be achieved by considering the patient's history, physical examination, laboratory analysis or by different imaging modalities. Abdominal compartment syndrome (ACS) occurs due to elevated intra-abdominal pressure (IAP), and can be diagnosed by measurement of BP. We observed in our clinical routine elevated IAP levels in patients with acute abdomen. METHODS: Two groups were established: one containing 65 consecutive patients diagnosed as having acute abdomen in the emergency room, and the control group of 10 consecutive patients with no acute abdominal complaints elected for laparoscopic operation. IAP measurements were performed before the operations. BP was measured in the supine position with 50 mL of sterile saline instilled into the bladder after the bladder had been emptied. The catheter was connected to a water manometer with the reference point being the symphisis pubis, BP levels greater than 7 cmH(2)O were accepted as abnormal and interpreted as a diagnostic criteria for acute abdomen. RESULTS: Sensitivity, specificity, positive predictive value, negative predictive value and the accuracy are calculated 95.4%, 80%, 96.9%, 72.7%, 93.3%, respectively. CONCLUSION: We found elevated IAP may support the physician's diagnosis of acute abdomen with approximately 27.3% false negative rate. [Asian J Surg 2009;32(1):33-8]
引用
收藏
页码:33 / 38
页数:6
相关论文
共 50 条
  • [1] Role of intra-abdominal pressure measurement in patients with acute abdomen requiring exploratory laparotomy
    Pathania, Sumit
    Gupta, Arun Kumar
    Gupta, Nikhil
    Agrawal, Himanshu
    Durga, C. K.
    [J]. POLISH JOURNAL OF SURGERY, 2022, 94 (05) : 40 - 45
  • [2] CLINICAL SIGNIFICANCE OF INTRA-ABDOMINAL PRESSURE MEASUREMENT IN PATIENTS WITH ACUTE ABDOMEN REQUIRING EXPLORATORY LAPAROTOMY
    Goswami, Binita
    Pathania, Sumit
    Gupta, Arun K.
    Gupta, Nikhil
    [J]. GUT, 2020, 69 : A32 - A32
  • [3] The Diagnostic Value of Intra-abdominal Pressure in Patients with Blunt Acute Abdominal Trauma
    Narci, Huseyin
    Uzun, Hukum
    Karabulut, Keziban Ucar
    [J]. CUKUROVA MEDICAL JOURNAL, 2012, 37 (03): : 157 - 161
  • [4] Intra-abdominal pressure measurement: validation of intragastric pressure as a measure of intra-abdominal pressure
    Turnbull, D.
    Webber, S.
    Hamnegard, C. H.
    Mills, G. H.
    [J]. BRITISH JOURNAL OF ANAESTHESIA, 2007, 98 (05) : 628 - 634
  • [5] AN OBSERVATION ON SIGNIFICANCE OF INTRA-ABDOMINAL PRESSURE WITH RESPECT TO PROGNOSIS OF ACUTE ABDOMEN CASES
    Kumar, Ravikant
    Jha, Rohit Kumar
    Mundu, Mrityunjay
    Malua, Shital
    Baxla, R. G.
    [J]. JOURNAL OF EVOLUTION OF MEDICAL AND DENTAL SCIENCES-JEMDS, 2013, 2 (20): : 3428 - 3438
  • [6] Intra-abdominal desmoid tumour presenting as an acute abdomen
    Bellamy, Fiona
    Gunawardene, Ashok
    Osipov, Vladimir
    Aljanabi, Imad
    [J]. ANZ JOURNAL OF SURGERY, 2019, 89 (12) : 1654 - 1655
  • [7] Problematic of intra-abdominal pressure measurement
    Neumann, P.
    [J]. ANAESTHESIST, 2009, 58 (05): : 527 - 531
  • [8] Noninvasive intra-abdominal pressure measurement
    Braun, Georg
    Schaefer, Kristina
    [J]. MEDIZINISCHE KLINIK-INTENSIVMEDIZIN UND NOTFALLMEDIZIN, 2022, 117 (08) : 658 - 666
  • [9] Validation of transurethral intra-abdominal pressure measurement in acute heart failure
    Zymlinski, Robert
    Biegus, Jan
    Sokolski, Mateusz
    Jankowska, Ewa A.
    Banasiak, Waldemar
    Ponikowski, Piotr
    [J]. POLISH ARCHIVES OF INTERNAL MEDICINE-POLSKIE ARCHIWUM MEDYCYNY WEWNETRZNEJ, 2018, 128 (06): : 403 - 405
  • [10] Continuous intra-abdominal pressure measurement technique at severe acute pancreatitis
    Senchuk, G. A.
    Jarkov, O. G.
    Litvin, A. A.
    Mauda, S. L.
    Ali, A. A.
    [J]. ACTA CLINICA BELGICA, 2007, 62 : 299 - 299