Direct measurement of intra-abdominal pressure with a solid microtranducer

被引:22
|
作者
Pracca F.F. [1 ]
Biestro A.A. [1 ]
Moraes L. [1 ]
Puppo C.B. [1 ]
Calvo S.M. [1 ]
Gorrasi J. [1 ]
Cancela M. [1 ]
机构
[1] Department of Intensive Care Medicine, Hospital de Clinicas, Montevideo 11600, Avda Italia s/n
关键词
Abdominal compartment syndrome; Codman microsensor; Intra-abdominal pressure; Intravesical pressure; Pressure monitor;
D O I
10.1007/s10877-007-9071-2
中图分类号
学科分类号
摘要
Objective: To describe a direct intra-abdominal pressure (IAP) measurement technique using a solid microsensor comparing its values with the ones simultaneously obtained by means of Kron's technique. Comparative study between two different methods to measure intra-abdominal pressure in a multidisciplinary intensive care unit of a university hospital. Methods: In 11 critical patients considered irreversibly ill, IAP was simultaneously measured via Kron's technique (IAPK) and by direct measure (IAPC) through an abdominal tap with a Codman microsensor, inserted through it. Several measurements were obtained at different PEEP levels (0, 10 and 20 cm of H20) and bed inclination (0°, 40° and 60°). Results: 92 simultaneous measurements of IAPK and IAPC were made. The difference between both measurements (mean ±SD) were: 0.286 ± 0.938 mmHg. The correlation coefficient was r = 0.98. Bland-Altman plot showed a narrow distribution: 95% of the differences were between 1.87 mmHg of each averaged value. No complications with IAPC measurements were found. Conclusions: Direct IAP measurement with a Codman microsensor allows continuous monitoring without urinary tract manipulation, is simple to use and to calibrate, minimally invasive and appropriate for patients at risk to develop abdominal compartmental syndrome. Due to its cost it should be reserved for selected critical patients where standard techniques are contraindicated or can be inaccurate. © Springer Science+Business Media, Inc. 2007.
引用
收藏
页码:167 / 170
页数:3
相关论文
共 50 条
  • [31] THE MEASUREMENT OF INTRA-ABDOMINAL PRESSURE AS A CRITERION FOR ABDOMINAL RE-EXPLORATION
    KRON, IL
    HARMAN, PK
    NOLAN, SP
    ANNALS OF SURGERY, 1984, 199 (01) : 28 - 30
  • [32] Noninvasive Assessment of Intra-Abdominal Pressure by Measurement of Abdominal Wall Tension
    van Ramshorst, Gabrielle H.
    Salih, Mahdi
    Hop, Wim C. J.
    van Waes, Oscar J. F.
    Kleinrensink, Gert-Jan
    Goossens, Richard H. M.
    Lange, Johan F.
    JOURNAL OF SURGICAL RESEARCH, 2011, 171 (01) : 240 - 244
  • [33] Studies on intra-abdominal pressure I Negative intra-abdominal pressure as a normal condition
    Wagoner, GW
    AMERICAN JOURNAL OF THE MEDICAL SCIENCES, 1926, 171 : 697 - 707
  • [34] Effect of abdominal negative-pressure wound therapy on the measurement of intra-abdominal pressure
    Federico Garcia, Alberto
    Ignacio Sanchez, Alvaro
    Jose Gutierrez, Alvaro
    Gabriel Bayona, Juan
    Paula Naranjo, Maria
    Lago, Sebastian
    Carlos Puyana, Juan
    JOURNAL OF SURGICAL RESEARCH, 2018, 227 : 112 - 118
  • [35] Clinical evaluation of an air-capsule probe for the direct measurement of intra-abdominal pressure after abdominal surgery
    Schachtrupp, A.
    Schumacher, O.
    Biermann, A.
    Becker, H. P.
    Toens, C.
    ACTA CLINICA BELGICA, 2007, 62 : 251 - 251
  • [36] Estimation of intra-abdominal pressure by bladder pressure measurement: Validity and methodology
    Fusco, MA
    Martin, RS
    Chang, MC
    JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2001, 50 (02): : 297 - 302
  • [37] Evaluation of two novel methods for the direct and continuous measurement of the intra-abdominal pressure in a porcine model
    Schachtrupp, A
    Tons, C
    Fackeldey, V
    Hoer, J
    Reinges, M
    Schumpelick, V
    INTENSIVE CARE MEDICINE, 2003, 29 (09) : 1605 - 1608
  • [38] A Single-Lumen Central Venous Catheter for Continuous and Direct Intra-abdominal Pressure Measurement
    Oscar J. F. van Waes
    Jean B. Jaquet
    Wim C. J. Hop
    Marjolein J. M. Morak
    Jan M. Ijzermans
    Jan Koning
    European Journal of Trauma and Emergency Surgery, 2009, 35 : 532 - 537
  • [39] A Single-Lumen Central Venous Catheter for Continuous and Direct Intra-abdominal Pressure Measurement
    van Waes, Oscar J. F.
    Jaquet, Jean B.
    Hop, Wim C. J.
    Morak, Marjolein J. M.
    Ijzermans, Jan M.
    Koning, Jan
    EUROPEAN JOURNAL OF TRAUMA AND EMERGENCY SURGERY, 2009, 35 (06) : 532 - 537
  • [40] Evaluation of two novel methods for the direct and continuous measurement of the intra-abdominal pressure in a porcine model
    Alexander Schachtrupp
    Christian Tons
    Volker Fackeldey
    Joerg Hoer
    Marcus Reinges
    Volker Schumpelick
    Intensive Care Medicine, 2003, 29 : 1605 - 1608