Electrode modified with a composite film of ZnO nanorods and Ag nanoparticles as a sensor for hydrogen peroxide

被引:140
|
作者
Lin, Chia-Yu [1 ]
Lai, Yi-Hsuan [1 ,2 ]
Balamurugan, A. [1 ]
Vittal, R. [1 ]
Lin, Chii-Wann [2 ,3 ]
Ho, Kuo-Chuan [1 ,4 ]
机构
[1] Natl Taiwan Univ, Dept Chem Engn, Taipei 10617, Taiwan
[2] Natl Taiwan Univ, Inst Biomed Engn, Taipei 10617, Taiwan
[3] Natl Taiwan Univ, Inst Elect Engn, Taipei 10617, Taiwan
[4] Natl Taiwan Univ, Inst Polymer Sci & Engn, Taipei 10617, Taiwan
关键词
Amperometric detection; Hydrogen peroxide sensor; Modified electrode; Silver nanoparticles; Zinc oxide nanorods; PHOTOCHEMICAL-SYNTHESIS; SILVER; REDUCTION;
D O I
10.1016/j.talanta.2010.04.047
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A conducting fluorine-doped tin oxide (FTO) electrode, first modified with zinc oxide nanorods (ZnONRs) and subsequently attached with photosynthesized silver nanoparticles (AgNPs), designated as AgNPs/ZnONRs/FTO electrode, was used as an amperometric sensor for the determination of hydrogen peroxide. The first layer (ZnONRs) was obtained by chemical bath deposition (CBD), and was utilized simultaneously as the catalyst for the photoreduction of Ag ions under UV irradiation and as the matrix for the immobilization of AgNPs. The aspect ratio of ZnONRs to be deposited was optimized by controlling the number of their CBDs to render enough surface area for Ag deposition, and the amount of AgNPs to be attached was controlled by adjusting the UV-irradiation time. The immobilized AgNPs showed excellent electrocatalytic response to the reduction of hydrogen peroxide. The resultant amperometric sensor showed 10-fold enhanced sensitivity for the detection of H2O2, compared to that without AgNPs, i.e., only with a layer of ZnONRs. Amperometric determination of H2O2 at -0.55 V gave a limit of detection of 0.9 mu M (S/N = 3) and a sensitivity of 152.1 mA M-1 cm(-2) up to 0.983 mM, with a response time (steady-state, t(95)) of 30-40 s. The selectivity of the sensor was investigated against ascorbic acid (AA) and uric acid (UA). Energy dispersive X-ray (EDX) analysis, transmission electron microscopic (TEM) image, X-ray diffraction (XRD) patterns, cyclic voltammetry (CV), and scanning electron microscopic (SEM) images were utilized to characterize the modified electrode. Sensing properties of the modified electrode were studied both by CV and amperometric analysis. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:340 / 347
页数:8
相关论文
共 50 条
  • [1] A novel nonenzymatic hydrogen peroxide sensor based on reduced graphene oxide/ZnO composite modified electrode
    Palanisamy, Selvakumar
    Chen, Shen-Ming
    Sarawathi, Ramiah
    SENSORS AND ACTUATORS B-CHEMICAL, 2012, 166 : 372 - 377
  • [2] Hydrogen peroxide sensor based on glassy carbon electrode modified with β-manganese dioxide nanorods
    Ai-Jun Wang
    Pei-Pei Zhang
    Yong-Fang Li
    Jiu-Ju Feng
    Wen-Ju Dong
    Xue-Yan Liu
    Microchimica Acta, 2011, 175 : 31 - 37
  • [3] Hydrogen peroxide sensor based on glassy carbon electrode modified with β-manganese dioxide nanorods
    Wang, Ai-Jun
    Zhang, Pei-Pei
    Li, Yong-Fang
    Feng, Jiu-Ju
    Dong, Wen-Ju
    Liu, Xue-Yan
    MICROCHIMICA ACTA, 2011, 175 (1-2) : 31 - 37
  • [4] Gel-assisted synthesis of Ag nanoparticles: a novel hydrogen peroxide sensor based on Ag nanoparticles-carbon nanotube composite film
    Fereshteh Chekin
    Samira Bagheri
    Sharifah Bee Abd Hamid
    Russian Journal of Electrochemistry, 2014, 50 : 1164 - 1169
  • [5] Gel-assisted synthesis of Ag nanoparticles: a novel hydrogen peroxide sensor based on Ag nanoparticles-carbon nanotube composite film
    Chekin, Fereshteh
    Bagheri, Samira
    Hamid, Sharifah Bee Abd
    RUSSIAN JOURNAL OF ELECTROCHEMISTRY, 2014, 50 (12) : 1164 - 1169
  • [6] Non-enzymatic hydrogen peroxide amperometric sensor based on a glassy carbon electrode modified with an MWCNT/polyaniline composite film and platinum nanoparticles
    Zhong, Huaan
    Yuan, Ruo
    Chai, Yaqin
    Zhang, Yu
    Wang, Chengyan
    Jia, Feng
    MICROCHIMICA ACTA, 2012, 176 (3-4) : 389 - 395
  • [7] Non-enzymatic hydrogen peroxide amperometric sensor based on a glassy carbon electrode modified with an MWCNT/polyaniline composite film and platinum nanoparticles
    Huaan Zhong
    Ruo Yuan
    Yaqin Chai
    Yu Zhang
    Chengyan Wang
    Feng Jia
    Microchimica Acta, 2012, 176 : 389 - 395
  • [8] A novel nonenzymatic hydrogen peroxide sensor based on Pd nanoparticles modified electrode
    Zhuang, Zhenjing
    MATERIALS AND COMPUTATIONAL MECHANICS, PTS 1-3, 2012, 117-119 : 790 - 794
  • [9] A novel hydrogen peroxide sensor based on Ag nanoparticles electrodeposited on DNA-networks modified glassy carbon electrode
    Cui, Kang
    Song, Yonghai
    Yao, Yong
    Huang, Zhenzhong
    Wang, Li
    ELECTROCHEMISTRY COMMUNICATIONS, 2008, 10 (04) : 663 - 667
  • [10] The electrodeposition of Ag nanoparticles on a type I collagen-modified glassy carbon electrode and their applications as a hydrogen peroxide sensor
    Song, Yonghai
    Cui, Kang
    Wang, Li
    Chen, Shouhui
    NANOTECHNOLOGY, 2009, 20 (10)