A novel nonenzymatic hydrogen peroxide sensor based on reduced graphene oxide/ZnO composite modified electrode

被引:191
|
作者
Palanisamy, Selvakumar [1 ]
Chen, Shen-Ming [1 ]
Sarawathi, Ramiah [2 ]
机构
[1] Natl Taipei Univ Technol, Dept Chem Engn & Biotechnol, Taipei 106, Taiwan
[2] Madurai Kamaraj Univ, Sch Chem, Dept Mat Sci, Madurai 625021, Tamil Nadu, India
来源
关键词
Reduced graphene oxide; Zinc oxide; Electrocatalysis; Hydrogen peroxide; DIRECT ELECTROCHEMISTRY; ZINC-OXIDE; REDUCTION; ZNO; FILM;
D O I
10.1016/j.snb.2012.02.075
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel nonenzymatic, amperometric sensor for hydrogen peroxide (H2O2) was developed based on an electrochemically prepared reduced graphene oxide (RGO)/zinc oxide (ZnO) composite using a simple and cost effective approach. RGO/ZnO composite was fabricated on a glassy carbon electrode (GCE) by a green route based on simultaneous electrodeposition of ZnO and electrochemical reduction of graphene oxide (GO). The morphology of the as-prepared RGO/ZnO composite was investigated by scanning electron microscopy (SEM). Attenuated total reflectance (ATR) spectroscopy has also been performed to confirm the ample reduction of oxygen functionalities located at graphene oxide (GO). The electrochemical performance of the RGO/ZnO composite modified GCE was studied by amperometric technique, and the resulting electrode displays excellent performance towards hydrogen peroxide (H2O2) at -0.38 V in the linear response range from 0.02 to 22.48 mu M, with a correlation coefficient of 0.9951 and short response time (<5 s). The proposed sensor also has good operational and storage stability with appreciable anti-interferring ability. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:372 / 377
页数:6
相关论文
共 50 条
  • [1] A novel nonenzymatic hydrogen peroxide sensor based on Pd nanoparticles modified electrode
    Zhuang, Zhenjing
    [J]. MATERIALS AND COMPUTATIONAL MECHANICS, PTS 1-3, 2012, 117-119 : 790 - 794
  • [2] A novel nonenzymatic hydrogen peroxide electrochemical sensor based on SnO2-reduced graphene oxide nanocomposite
    Fu, Li
    Zheng, Yuhong
    Wang, Aiwu
    Cai, Wen
    Fu, Zhuxian
    Peng, Feng
    [J]. Sensor Letters, 2015, 13 (01) : 81 - 84
  • [3] A Hydrogen Peroxide Electrochemical Sensor Based on an Alginate/Water-Soluble Prussian Blue/Reduced Graphene Oxide Composite Modified Electrode
    Yoon, Ok Ja
    [J]. POLYMER-KOREA, 2018, 42 (06) : 1104 - 1109
  • [4] A novel nonenzymatic hydrogen peroxide sensor based on MnO2/graphene oxide nanocomposite
    Li, Limiao
    Du, Zhifeng
    Liu, Shuang
    Hao, Quanyi
    Wang, Yanguo
    Li, Qiuhong
    Wang, Taihong
    [J]. TALANTA, 2010, 82 (05) : 1637 - 1641
  • [5] Au nanoparticles decorated reduced graphene oxide for the fabrication of disposable nonenzymatic hydrogen peroxide sensor
    Dhara, Keerthy
    Ramachandran, T.
    Nair, Bipin G.
    Babu, T. G. Satheesh
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2016, 764 : 64 - 70
  • [6] Modified glassy carbon electrode based on myoglobin and reduced graphene oxide for hydrogen peroxide detection
    Szoke, A.
    Turdean, G.
    Muresan, L.
    [J]. BULGARIAN CHEMICAL COMMUNICATIONS, 2017, 49 : 147 - 154
  • [7] A novel nonenzymatic hydrogen peroxide sensor based on silver nanoparticles and ionic liquid functionalized multiwalled carbon nanotube composite modified electrode
    Li, Xiaoyan
    Liu, Yuanxiang
    Zheng, Lichun
    Dong, Mingjun
    Xue, Zhonghua
    Lu, Xiaoquan
    Liu, Xiuhui
    [J]. ELECTROCHIMICA ACTA, 2013, 113 : 170 - 175
  • [8] A Novel Enzymatic Glucose Biosensor and Nonenzymatic Hydrogen Peroxide Sensor Based on (3-Aminopropyl) Triethoxysilane Functionalized Reduced Graphene Oxide
    Guler, Muhammet
    Turkoglu, Vedat
    Kivanc, Mehmet Riza
    [J]. ELECTROANALYSIS, 2017, 29 (11) : 2507 - 2515
  • [9] Electrochemically Reduced Graphene Oxide Film Modified Electrode for Detection of Hydrogen Peroxide
    Li, Juan
    Yang, Juan
    Yang, Zhan-jun
    Ji, Ping
    Zhou, Yi-mei
    Diao, Guo-wang
    [J]. PROGRESS IN FUNCTIONAL MATERIALS, 2013, 538 : 165 - 168
  • [10] A novel nonenzymatic hydrogen peroxide sensor based on a polypyrrole nanowire-copper nanocomposite modified gold electrode
    Zhang, Tingting
    Yuan, Ruo
    Chai, Yaqin
    Li, Wenjuan
    Ling, Shujuan
    [J]. SENSORS, 2008, 8 (08) : 5141 - 5152