A novel nonenzymatic hydrogen peroxide sensor based on reduced graphene oxide/ZnO composite modified electrode

被引:191
|
作者
Palanisamy, Selvakumar [1 ]
Chen, Shen-Ming [1 ]
Sarawathi, Ramiah [2 ]
机构
[1] Natl Taipei Univ Technol, Dept Chem Engn & Biotechnol, Taipei 106, Taiwan
[2] Madurai Kamaraj Univ, Sch Chem, Dept Mat Sci, Madurai 625021, Tamil Nadu, India
来源
关键词
Reduced graphene oxide; Zinc oxide; Electrocatalysis; Hydrogen peroxide; DIRECT ELECTROCHEMISTRY; ZINC-OXIDE; REDUCTION; ZNO; FILM;
D O I
10.1016/j.snb.2012.02.075
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel nonenzymatic, amperometric sensor for hydrogen peroxide (H2O2) was developed based on an electrochemically prepared reduced graphene oxide (RGO)/zinc oxide (ZnO) composite using a simple and cost effective approach. RGO/ZnO composite was fabricated on a glassy carbon electrode (GCE) by a green route based on simultaneous electrodeposition of ZnO and electrochemical reduction of graphene oxide (GO). The morphology of the as-prepared RGO/ZnO composite was investigated by scanning electron microscopy (SEM). Attenuated total reflectance (ATR) spectroscopy has also been performed to confirm the ample reduction of oxygen functionalities located at graphene oxide (GO). The electrochemical performance of the RGO/ZnO composite modified GCE was studied by amperometric technique, and the resulting electrode displays excellent performance towards hydrogen peroxide (H2O2) at -0.38 V in the linear response range from 0.02 to 22.48 mu M, with a correlation coefficient of 0.9951 and short response time (<5 s). The proposed sensor also has good operational and storage stability with appreciable anti-interferring ability. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:372 / 377
页数:6
相关论文
共 50 条
  • [41] A Novel Nonenzymatic Hydrogen Peroxide Electrochemical Sensor Based on Facile Synthesis of Copper Oxide Nanoparticles Dopping into Graphene Sheets@Cerium Oxide Nanocomposites Sensitized Screen Printed Electrode
    He, Guo-wen
    Jiang, Jian-qing
    Wu, Dan
    You, Yi-lan
    Yang, Xin
    Wu, Feng
    Hu, Yang-jian
    [J]. INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2016, 11 (10): : 8486 - 8498
  • [42] Nonenzymatic Hydrogen Peroxide Sensor Based on Three-dimensional Ordered Macroporous Gold Film Modified Electrode
    Xuan Jie
    Jiang Li-Ping
    Zhu Jun-Jie
    [J]. CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2010, 38 (04) : 513 - 516
  • [43] Sensing hydrogen peroxide with a glassy carbon electrode modified with silver nanoparticles, AlOOH and reduced graphene oxide
    Ziyin Yang
    Chengcheng Qi
    Xiaohui Zheng
    Jianbin Zheng
    [J]. Microchimica Acta, 2016, 183 : 1131 - 1136
  • [44] Electrochemically Reduced Graphene Oxide-nafion/Au Nanoparticle Modified Electrode for Hydrogen Peroxide Sensing
    Lv, Yajie
    Wang, Fang
    Zhu, Hui
    Zou, Xiaorong
    Tao, Cheng-An
    Wang, Jianfang
    [J]. NANOMATERIALS AND NANOTECHNOLOGY, 2016, 6
  • [45] Developing an electrochemical sensor based on a carbon paste electrode modified with nano-composite of reduced graphene oxide and CuFe2O4 nanoparticles for determination of hydrogen peroxide
    Benvidi, Ali
    Nafar, Mohammad Taghi
    Jahanbani, Shahriar
    Tezerjani, Marzieh Dehghan
    Rezaeinasab, Masoud
    Dalirnasab, Sudabeh
    [J]. MATERIALS SCIENCE AND ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2017, 75 : 1435 - 1447
  • [46] A reagentless non-enzymatic hydrogen peroxide sensor presented using electrochemically reduced graphene oxide modified glassy carbon electrode
    Mutyala, Sankararao
    Mathiyarasu, Jayaraman
    [J]. MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2016, 69 : 398 - 406
  • [47] Reduced graphene oxide/ZnO nanocomposite modified electrode for the detection of tetracycline
    Durovic, Ana
    Stojanovic, Zorica
    Bytesnikova, Zuzana
    Kravic, Snezana
    Svec, Pavel
    Pribyl, Jan
    Richtera, Lukas
    [J]. JOURNAL OF MATERIALS SCIENCE, 2022, 57 (09) : 5533 - 5551
  • [48] Reduced graphene oxide/ZnO nanocomposite modified electrode for the detection of tetracycline
    Ana Đurović
    Zorica Stojanović
    Zuzana Bytešníková
    Snežana Kravić
    Pavel Švec
    Jan Přibyl
    Lukáš Richtera
    [J]. Journal of Materials Science, 2022, 57 : 5533 - 5551
  • [49] Direct Electrochemistry of Glucose Oxidase at Reduced Graphene Oxide/Zinc Oxide Composite Modified Electrode for Glucose Sensor
    Palanisamy, Selvakumar
    Vilian, A. T. Ezhil
    Chen, Shen-Ming
    [J]. INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2012, 7 (03): : 2153 - 2163
  • [50] A sensitive nonenzymatic hydrogen peroxide sensor using cadmium oxide nanoparticles/multiwall carbon nanotube modified glassy carbon electrode
    Butwong, Nutthaya
    Zhou, Lin
    Ng-Eontae, Wittaya
    Burakham, Rodjana
    Moore, Eric
    Srijaranai, Supalax
    Luong, John H. T.
    Glennon, Jeremy D.
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2014, 717 : 41 - 46