Electrode modified with a composite film of ZnO nanorods and Ag nanoparticles as a sensor for hydrogen peroxide

被引:140
|
作者
Lin, Chia-Yu [1 ]
Lai, Yi-Hsuan [1 ,2 ]
Balamurugan, A. [1 ]
Vittal, R. [1 ]
Lin, Chii-Wann [2 ,3 ]
Ho, Kuo-Chuan [1 ,4 ]
机构
[1] Natl Taiwan Univ, Dept Chem Engn, Taipei 10617, Taiwan
[2] Natl Taiwan Univ, Inst Biomed Engn, Taipei 10617, Taiwan
[3] Natl Taiwan Univ, Inst Elect Engn, Taipei 10617, Taiwan
[4] Natl Taiwan Univ, Inst Polymer Sci & Engn, Taipei 10617, Taiwan
关键词
Amperometric detection; Hydrogen peroxide sensor; Modified electrode; Silver nanoparticles; Zinc oxide nanorods; PHOTOCHEMICAL-SYNTHESIS; SILVER; REDUCTION;
D O I
10.1016/j.talanta.2010.04.047
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A conducting fluorine-doped tin oxide (FTO) electrode, first modified with zinc oxide nanorods (ZnONRs) and subsequently attached with photosynthesized silver nanoparticles (AgNPs), designated as AgNPs/ZnONRs/FTO electrode, was used as an amperometric sensor for the determination of hydrogen peroxide. The first layer (ZnONRs) was obtained by chemical bath deposition (CBD), and was utilized simultaneously as the catalyst for the photoreduction of Ag ions under UV irradiation and as the matrix for the immobilization of AgNPs. The aspect ratio of ZnONRs to be deposited was optimized by controlling the number of their CBDs to render enough surface area for Ag deposition, and the amount of AgNPs to be attached was controlled by adjusting the UV-irradiation time. The immobilized AgNPs showed excellent electrocatalytic response to the reduction of hydrogen peroxide. The resultant amperometric sensor showed 10-fold enhanced sensitivity for the detection of H2O2, compared to that without AgNPs, i.e., only with a layer of ZnONRs. Amperometric determination of H2O2 at -0.55 V gave a limit of detection of 0.9 mu M (S/N = 3) and a sensitivity of 152.1 mA M-1 cm(-2) up to 0.983 mM, with a response time (steady-state, t(95)) of 30-40 s. The selectivity of the sensor was investigated against ascorbic acid (AA) and uric acid (UA). Energy dispersive X-ray (EDX) analysis, transmission electron microscopic (TEM) image, X-ray diffraction (XRD) patterns, cyclic voltammetry (CV), and scanning electron microscopic (SEM) images were utilized to characterize the modified electrode. Sensing properties of the modified electrode were studied both by CV and amperometric analysis. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:340 / 347
页数:8
相关论文
共 50 条
  • [11] A sensitive amperometric hydrogen peroxide sensor based on thionin/EDTA/carbon nanotubes—chitosan composite film modified electrode
    Keying Zhang
    Li Zhang
    Jigui Xu
    Cong Wang
    Tao Geng
    Hongyan Wang
    Jun Zhu
    Microchimica Acta, 2010, 171 : 139 - 144
  • [12] An unmediated hydrogen peroxide sensor based on a hemoglobin-SDS film modified electrode
    Fan, CH
    Suzuki, I
    Chen, Q
    Li, GX
    Anzai, J
    ANALYTICAL LETTERS, 2000, 33 (13) : 2631 - 2644
  • [13] Hydrogen Peroxide Electrochemical Sensor Based on Ag/Cu Bimetallic Nanoparticles Modified on Polypyrrole
    Guan, Yanxun
    Xu, Fen
    Sun, Lixian
    Luo, Yumei
    Cheng, Riguang
    Zou, Yongjin
    Liao, Lumin
    Cao, Zhong
    SENSORS, 2023, 23 (20)
  • [14] A hydrogen peroxide sensor based on Ag nanoparticles electrodeposited on natural nano-structure attapulgite modified glassy carbon electrode
    Chen, Huihui
    Zhang, Zhe
    Cai, Dongqing
    Zhang, Shengyi
    Zhang, Bailin
    Tang, Jilin
    Wu, Zhengyan
    TALANTA, 2011, 86 : 266 - 270
  • [15] Enhanced Sensitive Hydrogen Peroxide Sensor Based on C60-Nafion/Pyrocatechol Violet Composite Film Modified Electrode
    Sheng, Qing-Lin
    Shen, Yu
    Zheng, Jian-Bin
    Zhang, Hong-Fang
    SENSOR LETTERS, 2012, 10 (3-4) : 1007 - 1011
  • [16] A sensitive amperometric hydrogen peroxide sensor based on thionin/EDTA/carbon nanotubes-chitosan composite film modified electrode
    Zhang, Keying
    Zhang, Li
    Xu, Jigui
    Wang, Cong
    Geng, Tao
    Wang, Hongyan
    Zhu, Jun
    MICROCHIMICA ACTA, 2010, 171 (1-2) : 139 - 144
  • [17] A novel hydrogen peroxide sensor based on Ag nanoparticles electrodeposited on chitosan-graphene oxide/cysteamine-modified gold electrode
    Wang, Li
    Zhu, Haozhi
    Hou, Haoqing
    Zhang, Zhiyao
    Xiao, Xianping
    Song, Yonghai
    JOURNAL OF SOLID STATE ELECTROCHEMISTRY, 2012, 16 (04) : 1693 - 1700
  • [18] A novel hydrogen peroxide sensor based on Ag nanoparticles electrodeposited on chitosan-graphene oxide/cysteamine-modified gold electrode
    Li Wang
    Haozhi Zhu
    Haoqing Hou
    Zhiyao Zhang
    Xianping Xiao
    Yonghai Song
    Journal of Solid State Electrochemistry, 2012, 16 : 1693 - 1700
  • [19] Non-enzymatic hydrogen peroxide sensor using an electrode modified with iron pentacyanonitrosylferrate nanoparticles
    Habib Razmi
    Rahim Mohammad-Rezaei
    Microchimica Acta, 2010, 171 : 257 - 265
  • [20] Non-enzymatic hydrogen peroxide sensor using an electrode modified with iron pentacyanonitrosylferrate nanoparticles
    Razmi, Habib
    Mohammad-Rezaei, Rahim
    MICROCHIMICA ACTA, 2010, 171 (3-4) : 257 - 265