Design of an experimental system for dual energy X-ray CT

被引:0
|
作者
Sukovic, P [1 ]
Clinthorne, NH [1 ]
机构
[1] Univ Michigan, Ann Arbor, MI 48109 USA
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We present the design of a dual energy (DE) X-ray computed tomography (CT) test bench. It employs amorphous silicon (a-Si:H) imaging arrays and helical cone-beam geometry. Our goals are to evaluate: (1) the applicability of a-Si:H imaging arrays for tomography; (2) how our previously published dual energy penalized weighted least squares (DE PWLS) reconstruction method performs on experimentally acquired data; and (3) the optimal imaging geometry. This will allow us to design a setting that can be used clinically for attenuation correction for emission tomography, various quantitative computed tomography (QCT) applications, and removal of metal streak artifacts.
引用
收藏
页码:1021 / 1022
页数:2
相关论文
共 50 条
  • [1] First Dual MeV Energy X-ray CT for Container Inspection: Design, Algorithm, and Preliminary Experimental Results
    Li, Liang
    Zhao, Tiao
    Chen, Zhiqiang
    IEEE ACCESS, 2018, 6 : 45534 - 45542
  • [2] Dual-energy X-ray CT by Compton scattering hard X-ray source
    Kaneyasu, T
    Uesaka, N
    Dobashi, K
    Torikoshi, M
    2005 IEEE PARTICLE ACCELERATOR CONFERENCE (PAC), VOLS 1-4, 2005, : 1680 - 1682
  • [3] Alternating minimization algorithm for dual energy X-ray CT
    O'Sullivan, JA
    Benac, J
    Williamson, JF
    2004 2ND IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING: MACRO TO NANO, VOLS 1 and 2, 2004, : 579 - 582
  • [4] APPLICATION OF A DUAL-ENERGY MONOCHROMATIC X-RAY CT ALGORITHM TO POLYCHROMATIC X-RAY CT: A FEASIBILITY STUDY
    Chang, S.
    Lee, H. K.
    Cho, G.
    NUCLEAR ENGINEERING AND TECHNOLOGY, 2012, 44 (01) : 61 - 70
  • [5] Experimental Comparison of Proton CT and Dual Energy X-Ray CT in Terms of Relative Stopping Power Accuracy
    Dedes, G.
    Dickmann, J.
    Wesp, P.
    Johnson, R.
    Pankuch, M.
    Bashkirov, V.
    Schulte, R.
    Landry, G.
    Parodi, K.
    MEDICAL PHYSICS, 2019, 46 (06) : E127 - E127
  • [6] Active dual energy x-ray detector: Experimental characterization
    Alvarez, RE
    Seibert, JA
    Poage, TF
    PHYSICS OF MEDICAL IMAGING - MEDICAL IMAGING 1997, 1997, 3032 : 419 - 426
  • [7] Experimental comparison of dual energy x-ray image detectors
    Alvarez, RE
    Seibert, JA
    PHYSICS OF MEDICAL IMAGING: MEDICAL IMAGING 1996, 1996, 2708 : 534 - 543
  • [8] Energy dependent systematic errors in dual-energy X-ray CT
    Goh, KL
    Liew, SC
    Hasegawa, BH
    1995 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD, VOLS 1-3, 1996, : 1587 - 1591
  • [9] Experimental comparison of proton CT and dual energy x-ray CT for relative stopping power estimation in proton therapy
    Dedes, George
    Dickmann, Jannis
    Niepel, Katharina
    Wesp, Philipp
    Johnson, Robert P.
    Pankuch, Mark
    Bashkirov, Vladimir
    Rits, Simon
    Volz, Lennart
    Schulte, Reinhard W.
    Landry, Guillaume
    Parodi, Katia
    PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (16):
  • [10] X-Ray Filter Design and Its Evaluation in Dual-Energy X-Ray Absorptiometry (DXA)
    Kim, Kwang Hyun
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2010, 57 (04) : 2155 - 2158