Three-dimensional versus four-dimensional dose calculation for volumetric modulated arc therapy of hypofractionated treatments

被引:23
|
作者
Ehrbar, Stefanie [1 ]
Lang, Stephanie
Stieb, Sonja
Riesterer, Oliver
Stark, Luisa Sabrina
Guckenberger, Matthias
Kloeck, Stephan
机构
[1] Univ Zurich Hosp, Dept Radiat Oncol, Ramistr 100, CH-8091 Zurich, Switzerland
来源
ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK | 2016年 / 26卷 / 01期
基金
瑞士国家科学基金会;
关键词
VMAT; respiratory motion; interplay effect; SBRT; DOSIMETRIC IMPACT; BREATHING MOTION; TARGET VOLUME; ORGAN MOTION; DELIVERY; RADIOTHERAPY; SIMULATION;
D O I
10.1016/j.zemedi.2015.06.010
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Respiratory motion is a non-negligible source of uncertainty in radiotherapy. A common approach is to delineate the target volume in all respiratory phases (ITV) and to calculate a treatment plan using the average reconstruction of the four-dimensional computed tomography (4DCT) scans. In this study the extent of the interplay effect caused by interaction between dynamic dose delivery and respiratory tumor motion, as well as other motion effects were investigated. These effects are often ignored when the ITV concept is used. Methods and Materials: Nine previously treated patients with in ten abdominal or thoracic cancer lesions (3 liver, 3 adrenal glands and 4 lung lesions) were selected for this planning study. For all patients, phase-sorted respiration-correlated 4DCT scans were taken, and volumetric modulated arc therapy (VMAT) treatments were planned using the ITV concept. Margins from ITV to planning target volume (PTV) of 3-10 mm were used. Plans were optimized and dose distributions were calculated on the average reconstruction of the 4DCT. 4D dose distributions were calculated to evaluate motion effects, caused by the interference of dynamic treatment delivery with respiratory tumor motion and inhomogeneously planned target dose. These calculations were performed on the phase sorted CT series with a respiration-correlated assignment of the treatment plan's monitor units (MU) to the respiration phases of the 4DCT. The 4D dose was accumulated with rigid as well as deformable registrations of the CT series and compared to the original 3D dose distribution. Maximum, minimum and mean doses to ITV and PTV, and maximum or mean doses to organs at risk (OAR), were compared after rigid accumulation. The dose variation in the gross tumor volume (GTV) was compared after deformable registration. Results: Using rigid registrations, variations in the investigated dose parameters between 3D and 4D dose calculations were found to be within -2.1% to 1.4% for all target volumes and within -0.8% to 1.7% in OAR. Using deformable registrations, dose differences in the GTV were below 3.8% for dose accumulation of lung and adrenal gland patients. For liver patients the used deformable registrations were not considered to be robust enough. It was also shown that a major part of the dose differences originates from the Hounsfield unit differences between 3D and 4D calculations, regardless of the interplay effect. Conclusion: The evaluated motion effects during VMAT treatments resulted in negligible dose variability. Therefore, the approximation of calculating the dose on the average reconstruction of the 4DCT (3D dose calculation), instead of calculating on the respiration-correlated phase CTs (4D dose calculation) with assignment of the corresponding MUs, gives acceptable results.
引用
收藏
页码:45 / 53
页数:9
相关论文
共 50 条
  • [21] Volumetric Modulated Arc Therapy vs Intensity Modulated Radiotherapy for Three Dose Level Prostate Treatments
    Boylan, C. J.
    Rowbottom, C. G.
    CLINICAL ONCOLOGY, 2011, 23 (03) : S24 - S25
  • [22] Dosimetric evaluation of four-dimensional dose distributions of CyberKnife and volumetric-modulated arc radiotherapy in stereotactic body lung radiotherapy
    Chan, Mark K. H.
    Kwong, Dora L. W.
    Law, Gilbert M. L.
    Tam, Eric
    Tong, Anthony
    Lee, Venus
    Ng, Sherry C. Y.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2013, 14 (04): : 136 - 149
  • [23] Three-dimensional radiochromic film dosimetry for volumetric modulated arc therapy using a spiral water phantom
    Tanooka, Masao
    Doi, Hiroshi
    Miura, Hideharu
    Inoue, Hiroyuki
    Niwa, Yasue
    Takada, Yasuhiro
    Fujiwara, Masayuki
    Sakai, Toshiyuki
    Sakamoto, Kiyoshi
    Kamikonya, Norihiko
    Hirota, Shozo
    JOURNAL OF RADIATION RESEARCH, 2013, 54 (06) : 1153 - 1159
  • [24] A More Accurate Dose Calculation for Volumetric Modulated Arc Therapy
    Yang, J.
    Zhang, P.
    Hunt, M.
    Lim, S.
    LoSasso, T.
    Mageras, G.
    MEDICAL PHYSICS, 2012, 39 (06) : 4020 - 4020
  • [25] New algorithm to simulate organ movement and deformation for four-dimensional dose calculation based on a three-dimensional CT and fluoroscopy of the thorax
    Miyabe, Yuki
    Narita, Yuichiro
    Mizowaki, Takashi
    Matsuo, Yukinori
    Takayama, Kenji
    Takahashi, Kunio
    Kaneko, Shuji
    Kawada, Noriyuki
    Maruhashi, Akira
    Hiraoka, Masahiro
    MEDICAL PHYSICS, 2009, 36 (10) : 4328 - 4339
  • [26] Dose calculation for hypofractionated volumetric-modulated arc therapy: approximating continuous arc delivery and tongue-and-groove modeling
    Yang, Jie
    Tang, Grace
    Zhang, Pengpeng
    Hunt, Margie
    Lim, Seng B.
    LoSasso, Thomas
    Mageras, Gig
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2016, 17 (02): : 3 - 13
  • [27] The assessment of fetal neurobehavior by three-dimensional and four-dimensional ultrasound
    Kurjak, Asim
    Tikvica, Ana
    Stanojevic, Milan
    Miskovic, Berivoj
    Ahmed, Baldreldeen
    Azumendi, Guillermo
    Di Renzo, Gian Carlo
    JOURNAL OF MATERNAL-FETAL & NEONATAL MEDICINE, 2008, 21 (10): : 675 - 684
  • [28] Three-dimensional and four-dimensional ultrasound applications in fetal medicine
    Yagel, Simcha
    Cohen, Sarah M.
    Messing, Baruch
    Valsky, Dan V.
    CURRENT OPINION IN OBSTETRICS & GYNECOLOGY, 2009, 21 (02) : 167 - 174
  • [29] Three-dimensional and four-dimensional fetal echocardiography: a new frontier
    DeVore, GR
    CURRENT OPINION IN PEDIATRICS, 2005, 17 (05) : 592 - 604
  • [30] Three-dimensional and Four-dimensional Ultrasound: Techniques and Abdominal Applications
    Kim, Se Hyung
    Choi, Byung Ihn
    JOURNAL OF MEDICAL ULTRASOUND, 2007, 15 (04) : 228 - 242