New algorithm to simulate organ movement and deformation for four-dimensional dose calculation based on a three-dimensional CT and fluoroscopy of the thorax

被引:9
|
作者
Miyabe, Yuki [1 ]
Narita, Yuichiro [1 ]
Mizowaki, Takashi [1 ]
Matsuo, Yukinori [1 ]
Takayama, Kenji [1 ]
Takahashi, Kunio [2 ]
Kaneko, Shuji [2 ]
Kawada, Noriyuki [2 ]
Maruhashi, Akira [3 ]
Hiraoka, Masahiro [1 ]
机构
[1] Kyoto Univ, Grad Sch Med, Dept Radiat Oncol & Image Appl Therapy, Kyoto 6068507, Japan
[2] Mitsubishi Heavy Ind Co Ltd, Med Syst Adm Off, Hiroshima Machinery Works, Hiroshima 7338553, Japan
[3] Kyoto Univ, Inst Res Reactor, Dept Radiat Life Sci & Radiat Med Sci, Osaka 5900494, Japan
关键词
organ motion; deformable modeling; 4D-CT; lung tumor; LUNG-TUMOR MOTION; RESPIRATION-CORRELATED CT; COMPUTED-TOMOGRAPHY; IMAGE REGISTRATION; MUTUAL-INFORMATION; TARGET VOLUME; LASER SCANNER; DYNAMIC MRI; RIB CAGE; RADIOTHERAPY;
D O I
10.1118/1.3213083
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The aim of this study was to develop a 4D-modeling algorithm, designated "3D+," to simulate organ movement and deformation for 4D dose calculation without the need for 4D-CT or deformable image registration and to assess the validity of this algorithm. Methods: This 3D+ algorithm virtually creates 4D-CT images by deforming static 3D-CT data according to a typical motion model and motion data at multiple observation points collected via fluoroscopy. A typical motion model intended for patients with lung tumors immobilized with a vacuum pillow inside a stereotactic body frame was constructed. The geometric accuracy of virtual 4D-CT images created using this 3D+ algorithm was evaluated in eight patients by comparing the simulated results with actual 4D-CT images in terms of visual assessment, landmark analysis, and comparison of the radial distance from the tumor centroid to the body or lung surface. Results: The average accuracy for all patients, as determined via landmark analysis, was 2.8 +/- 1.8 mm, very similar to results obtained through 4D-CT and deformable image registrations. Error in the radial distance from the tumor centroid to the body or lung surface was generally within 1.0 or 2.0 mm, respectively, in virtual versus actual 4D-CT images. Therefore, it is assumed that these geometric errors would have only negligible effects on dose calculation. Conclusions: 4D modeling of the thorax utilizing the 3D+ algorithm shows acceptable accuracy and is more suited for routine clinical use in terms of processing time than conventional 4D-CT and deformable image registration. The 3D+ algorithm may be useful for simulating dose distribution for advanced beam delivery techniques, such as real-time tumor tracking irradiation and adaptive radiation therapy. (C) 2009 American Association of Physicists in Medicine. [DOI: 10.1118/1.3213083]
引用
收藏
页码:4328 / 4339
页数:12
相关论文
共 50 条
  • [1] Three-dimensional versus four-dimensional dose calculation for breast IMRT
    Chung, J.
    Chun, M.
    Park, J. M.
    Kim, J.
    Shin, K.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2019, 133 : S703 - S703
  • [2] Three-Dimensional Versus Four-Dimensional Dose Calculation for Breast Intensity-Modulated Radiation Therapy
    Chung, J. H.
    Chun, M.
    Kim, J. I.
    Park, J. M.
    Shin, K. H.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2020, 108 (03): : E321 - E322
  • [3] Three-dimensional versus four-dimensional dose calculation for breast intensity-modulated radiation therapy
    Chung, Joo-Hyun
    Chun, Minsoo
    Kim, Jung-In
    Park, Jong Min
    Shin, Kyung Hwan
    [J]. BRITISH JOURNAL OF RADIOLOGY, 2020, 93 (1110):
  • [4] Three-dimensional versus four-dimensional dose calculation for volumetric modulated arc therapy of hypofractionated treatments
    Ehrbar, Stefanie
    Lang, Stephanie
    Stieb, Sonja
    Riesterer, Oliver
    Stark, Luisa Sabrina
    Guckenberger, Matthias
    Kloeck, Stephan
    [J]. ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2016, 26 (01): : 45 - 53
  • [5] Three-dimensional and four-dimensional fetal echocardiography: a new frontier
    DeVore, GR
    [J]. CURRENT OPINION IN PEDIATRICS, 2005, 17 (05) : 592 - 604
  • [6] Comparison Of The Planning Target Volume Based On Three-dimensional CT And Four-dimensional CT Images Of Thoracic Esophageal Cancer
    Wang, W.
    Li, J.
    Zhang, Y.
    Fan, T.
    Qi, H.
    Xing, J.
    [J]. JOURNAL OF THORACIC ONCOLOGY, 2012, 7 (09) : S307 - S307
  • [7] Comparison of the Planning Target Volume Based on Three-Dimensional CT and Four-Dimensional CT Images of Thoracic Esophageal Cancer
    Wang, W.
    Li, J.
    Shao, Q.
    Zhang, Y.
    Liu, S.
    Xu, M.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2015, 93 (03): : E161 - E162
  • [8] Comparison of planning target volumes based on three-dimensional and four-dimensional CT imaging of thoracic esophageal cancer
    Wang, Wei
    Li, Jianbin
    Zhang, Yingjie
    Shao, Qian
    Xu, Min
    Fan, Tingyong
    Wang, Jinzhi
    [J]. ONCOTARGETS AND THERAPY, 2016, 9 : 4785 - 4791
  • [9] The study of lung volume and respiratory movement based on four-dimensional CT
    Sun, Zong-wen
    Huang, Xiao-Yan
    Chen, Yuan-Yuan
    Bao, Yong
    Zhang, Li
    Huang, Shao-min
    Gao, Jian-ming
    Wang, Wei-hua
    He, Han
    Hu, Xiao
    Fan, Wei
    Chen, Ming
    [J]. JOURNAL OF THORACIC ONCOLOGY, 2009, 4 (09) : S940 - S940
  • [10] Comparison Of The Gross Tumor Volume Based On Three-dimensional CT And Four-dimensional CT Simulation Images Of Primary Liver Cancer
    Xing, J.
    Li, J. B.
    Zhang, Y. J.
    Li, F. X.
    Fan, T. Y.
    Xu, M.
    Shang, D. P.
    Han, J. J.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2011, 81 (02): : S358 - S358