Characterisation of a CZT detector for dosimetry of molecular radiotherapy

被引:9
|
作者
McAreavey, L. H. [1 ]
Harkness-Brennan, L. J. [1 ]
Colosimo, S. J. [1 ]
Judson, D. S. [1 ]
Boston, A. J. [1 ]
Boston, H. C. [1 ]
Nolan, P. J. [1 ]
Flux, G. D. [2 ]
Denis-Bacelar, A. M. [3 ]
Harris, B. [4 ]
Radley, I. [5 ]
Carroll, M. [6 ]
机构
[1] Univ Liverpool, Oliver Lodge Lab, Liverpool L69 7ZE, Merseyside, England
[2] Royal Marsden Hosp, Sutton SM2 5PT, Surrey, England
[3] Inst Canc Res, Sutton SM2 5NG, Surrey, England
[4] eV Prod Inc, Kromek USA, Saxonburg, PA 16056 USA
[5] Kromek Grp Plc, Sedgefield TS21 3FD, England
[6] Royal Liverpool & Broadgreen Univ Hosp, Liverpool L7 8XP, Merseyside, England
来源
基金
英国科学技术设施理事会;
关键词
Gamma camera; SPECT; PET PET/CT; coronary CT angiography (CTA); Gamma detectors (scintillators; CZT; HPG; HgI etc); Radiotherapy concepts; Solid state detectors; THYROID-CANCER; RADIOIODINE; THERAPY; SPECT; PET;
D O I
10.1088/1748-0221/12/03/P03001
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Apixelated cadmium zinc telluride (CZT) detector has been characterised for the purpose of developing a quantitative single photon emission computed tomography (SPECT) system for dosimetry of molecular radiotherapy (MRT). This is the aim of the Dosimetric Imaging with CZT (DEPICT) project, which is a collaboration between theUniversity of Liverpool, The Royal Marsden Hospital, The Royal Liverpool and Broadgreen University Hospital, and the commercial partner Kromek. CZT is a direct band gap semiconductor with superior energy resolution and stopping power compared to scintillator detectors used in current SPECT systems. The inherent detector properties have been investigated and operational parameters such as bias voltage and peaking time have been selected to optimise the performance of the system. Good energy resolution is required to discriminate gamma-rays that are scattered as they are emitted from the body and within the collimator, and high photon throughput is essential due to the high activities of isotopes administered in MRT. The system has an average measured electronic noise of 3.31 keV full width at half maximum (FWHM), determined through the use of an internal pulser. The energy response of the system was measured across the energy region of interest 59.5 keV to 364.5 keV and found to be linear. The reverse bias voltage and peaking time producing the optimum FWHM and maximum photon throughput were 600 V and 0.5 mu s respectively. The average dead time of the system was measured as 4.84 mu s and charge sharing was quantified to be 0.71% at 59.5 keV. A pixel sensitivity calibration map was created and planar images of the medical imaging isotopes Tc-99m and I-123 were acquired by coupling the device to a prototype collimator, thereby demonstrating the suitability of the detector for the DEPICT project.
引用
收藏
页数:17
相关论文
共 50 条
  • [31] Investigation of PTW's "microDiamond" detector for dosimetry in small animal radiotherapy research
    Kampfer, S.
    Wilkens, J. J.
    RADIOTHERAPY AND ONCOLOGY, 2016, 119 : S696 - S696
  • [32] Development of a novel diamond based Schottky diode detector for FLASH radiotherapy dosimetry
    Rinati, G. Verona
    Felici, G.
    Galante, F.
    Gasparini, A.
    Giuliano, L.
    Heinrich, S.
    Pacitti, M.
    Prestopino, G.
    Vanreusel, V.
    Verellen, D.
    Verona, C.
    Marinelli, M.
    RADIOTHERAPY AND ONCOLOGY, 2022, 170 : S244 - S245
  • [33] Design, realization, and characterization of a novel diamond detector prototype for FLASH radiotherapy dosimetry
    Marinelli, Marco
    Felici, Giuseppe
    Galante, Federica
    Gasparini, Alessia
    Giuliano, Lucia
    Heinrich, Sophie
    Pacitti, Matteo
    Prestopino, Giuseppe
    Vanreusel, Verdi
    Verellen, Dirk
    Verona, Claudio
    Rinati, Gianluca Verona
    MEDICAL PHYSICS, 2022, 49 (03) : 1902 - 1910
  • [34] Simulation and Measurement of Pixelated CZT Detector
    Fu, Jianqiang
    Li, Yulan
    Zhang, Lan
    Liu, Yilin
    Li, Jun
    Zhang, Wei
    Li, Yuanjing
    2014 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2014,
  • [35] Small Scale Inorganic X-ray Detector for Dosimetry in Radiotherapy and Brachytherapy
    Debnath, S. B. C.
    Tonneau, D.
    Fauquet, C.
    Tallet, A. Richard
    Goncalves, A.
    Ferre, M.
    Darreon, J.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2020, 108 (03): : E251 - E251
  • [36] Multi-detector dosimetry for QA in advanced radiotherapy modalities: a comparative study
    Pappas, E. P.
    Zoros, E.
    Anagnostopoulos, G.
    Antorkas, G.
    Pantelis, E.
    Karaiskos, P.
    RADIOTHERAPY AND ONCOLOGY, 2018, 127 : S462 - S463
  • [37] Interpolation in a Pixellated CZT γ-Radiation Detector
    Meier, Dirk
    Gheorghe, Codin
    Johansen, Tor Magnus
    Mikkelsen, Sindre
    Maehlum, Gunnar
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 4550 - 4556
  • [38] CZT detector technology for medical imaging
    Iniewski, K.
    JOURNAL OF INSTRUMENTATION, 2014, 9
  • [39] Monte Carlo Simulation of a CZT Detector
    Chun, Sung Dae
    Park, Se Hwan
    Ha, Jang Ho
    Kim, Han Soo
    Cho, Yoon Ho
    Kang, Sang Mook
    Kim, Yong Kyun
    Hong, Duk Geun
    JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY, 2008, : 549 - 552
  • [40] The internal dosimetry user group position statement on molecular radiotherapy
    Gear, Jonathan
    McGowan, Daniel
    Rojas, Bruno
    Craig, Allison J.
    Smith, April-Louise
    Scott, Catherine J.
    Scuffam, James
    Aldridge, Matthew
    Tipping, Jill
    BRITISH JOURNAL OF RADIOLOGY, 2021, 94 (1126):