Characterisation of a CZT detector for dosimetry of molecular radiotherapy

被引:9
|
作者
McAreavey, L. H. [1 ]
Harkness-Brennan, L. J. [1 ]
Colosimo, S. J. [1 ]
Judson, D. S. [1 ]
Boston, A. J. [1 ]
Boston, H. C. [1 ]
Nolan, P. J. [1 ]
Flux, G. D. [2 ]
Denis-Bacelar, A. M. [3 ]
Harris, B. [4 ]
Radley, I. [5 ]
Carroll, M. [6 ]
机构
[1] Univ Liverpool, Oliver Lodge Lab, Liverpool L69 7ZE, Merseyside, England
[2] Royal Marsden Hosp, Sutton SM2 5PT, Surrey, England
[3] Inst Canc Res, Sutton SM2 5NG, Surrey, England
[4] eV Prod Inc, Kromek USA, Saxonburg, PA 16056 USA
[5] Kromek Grp Plc, Sedgefield TS21 3FD, England
[6] Royal Liverpool & Broadgreen Univ Hosp, Liverpool L7 8XP, Merseyside, England
来源
基金
英国科学技术设施理事会;
关键词
Gamma camera; SPECT; PET PET/CT; coronary CT angiography (CTA); Gamma detectors (scintillators; CZT; HPG; HgI etc); Radiotherapy concepts; Solid state detectors; THYROID-CANCER; RADIOIODINE; THERAPY; SPECT; PET;
D O I
10.1088/1748-0221/12/03/P03001
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Apixelated cadmium zinc telluride (CZT) detector has been characterised for the purpose of developing a quantitative single photon emission computed tomography (SPECT) system for dosimetry of molecular radiotherapy (MRT). This is the aim of the Dosimetric Imaging with CZT (DEPICT) project, which is a collaboration between theUniversity of Liverpool, The Royal Marsden Hospital, The Royal Liverpool and Broadgreen University Hospital, and the commercial partner Kromek. CZT is a direct band gap semiconductor with superior energy resolution and stopping power compared to scintillator detectors used in current SPECT systems. The inherent detector properties have been investigated and operational parameters such as bias voltage and peaking time have been selected to optimise the performance of the system. Good energy resolution is required to discriminate gamma-rays that are scattered as they are emitted from the body and within the collimator, and high photon throughput is essential due to the high activities of isotopes administered in MRT. The system has an average measured electronic noise of 3.31 keV full width at half maximum (FWHM), determined through the use of an internal pulser. The energy response of the system was measured across the energy region of interest 59.5 keV to 364.5 keV and found to be linear. The reverse bias voltage and peaking time producing the optimum FWHM and maximum photon throughput were 600 V and 0.5 mu s respectively. The average dead time of the system was measured as 4.84 mu s and charge sharing was quantified to be 0.71% at 59.5 keV. A pixel sensitivity calibration map was created and planar images of the medical imaging isotopes Tc-99m and I-123 were acquired by coupling the device to a prototype collimator, thereby demonstrating the suitability of the detector for the DEPICT project.
引用
收藏
页数:17
相关论文
共 50 条
  • [21] A methodology for dosimetry audit of rotational radiotherapy using a commercial detector array
    Hussein, Mohammad
    Tsang, Yatman
    Thomas, Russell A. S.
    Gouldstone, Clare
    Maughan, David
    Snaith, Julia A. D.
    Bolton, Steven C.
    Nisbet, Andrew
    Clark, Catharine H.
    RADIOTHERAPY AND ONCOLOGY, 2013, 108 (01) : 78 - 85
  • [22] Comparison of the New MOSkin Detector and Fiber Optic Dosimetry System for Radiotherapy
    Kwan, Ian
    Lee, Bongsoo
    Yoo, Wook Jae
    Cho, Donghyun
    Jang, Kyoungwon
    Shin, Sanghun
    Carolan, Martin
    Lerch, Michael
    Perevertaylo, Vladimir
    Rosenfeld, Anatoly
    JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY, 2008, : 518 - 521
  • [23] Enhanced Molecular Breast Image quality through improved CZT detector performance
    Garcia, Timothy R.
    Kivenson, Aleksandr
    Malonson, Samuel
    Kudrolli, Hans
    2014 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2014,
  • [24] Characterisation of a plastic scintillation detector to be used in a multicentre stereotactic radiosurgery dosimetry audit
    Dimitriadis, A.
    Patallo, I. Silvestre
    Billas, I.
    Duane, S.
    Nisbet, A.
    Clark, C. H.
    RADIATION PHYSICS AND CHEMISTRY, 2017, 140 : 373 - 378
  • [25] NUKDOS: A software tool for dosimetry prior to molecular radiotherapy
    Kletting, Peter
    Schimmel, Sebastian
    Haenscheid, Heribert
    Fernandez, Maria
    Broeer, Joern
    Luster, Markus
    Nosske, Dietmar
    Lassmann, Michael
    Glatting, Gerhard
    JOURNAL OF NUCLEAR MEDICINE, 2014, 55
  • [26] Improving molecular radiotherapy dosimetry using anthropomorphic calibration
    Price, Emlyn
    Robinson, Andrew P.
    Cullen, David M.
    Tipping, Jill
    Calvert, Nick
    Hamilton, David
    Oldfield, Christopher
    Page, Emma
    Pietras, Ben
    Smith, Andrew
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2019, 58 : 40 - 46
  • [27] Characterisation of a scintillator for small fields and in-vivo dosimetry in MR guided Radiotherapy
    Cusumano, D.
    Placidi, L.
    D'Agostino, E.
    Boldrini, L.
    Valentini, V.
    De Spirito, M.
    Azario, L.
    RADIOTHERAPY AND ONCOLOGY, 2020, 152 : S701 - S702
  • [28] Study of Signal Filtering of a Dosimetry System with a Luminescent Plastic Detector, Designed for Dosimetry in Radiotherapy, by Means Spectral Analysis
    Nunez, L.
    MEDICAL PHYSICS, 2020, 47 (06) : E854 - E854
  • [29] The use of a CZT detector with robotic systems
    Selivanova, Anna
    Hulka, Jiri
    Seifert, Daniel
    Hlavac, Vaclav
    Krsek, Pavel
    Smutny, Vladimir
    Wagner, Libor
    Voltr, Josef
    Rubovic, Peter
    Cespirova, Irena
    Gryc, Lubomir
    APPLIED RADIATION AND ISOTOPES, 2020, 166
  • [30] Preamplifier design for CZT Frisch detector
    Shi, Zhubin
    Sang, Wenbin
    Qian, Yongbiao
    Teng, Jianyong
    Min, Jiahua
    Fan, Jianrong
    Liu, Jishan
    He Jishu/Nuclear Techniques, 2008, 31 (12): : 938 - 941