Characterisation of a CZT detector for dosimetry of molecular radiotherapy

被引:9
|
作者
McAreavey, L. H. [1 ]
Harkness-Brennan, L. J. [1 ]
Colosimo, S. J. [1 ]
Judson, D. S. [1 ]
Boston, A. J. [1 ]
Boston, H. C. [1 ]
Nolan, P. J. [1 ]
Flux, G. D. [2 ]
Denis-Bacelar, A. M. [3 ]
Harris, B. [4 ]
Radley, I. [5 ]
Carroll, M. [6 ]
机构
[1] Univ Liverpool, Oliver Lodge Lab, Liverpool L69 7ZE, Merseyside, England
[2] Royal Marsden Hosp, Sutton SM2 5PT, Surrey, England
[3] Inst Canc Res, Sutton SM2 5NG, Surrey, England
[4] eV Prod Inc, Kromek USA, Saxonburg, PA 16056 USA
[5] Kromek Grp Plc, Sedgefield TS21 3FD, England
[6] Royal Liverpool & Broadgreen Univ Hosp, Liverpool L7 8XP, Merseyside, England
来源
基金
英国科学技术设施理事会;
关键词
Gamma camera; SPECT; PET PET/CT; coronary CT angiography (CTA); Gamma detectors (scintillators; CZT; HPG; HgI etc); Radiotherapy concepts; Solid state detectors; THYROID-CANCER; RADIOIODINE; THERAPY; SPECT; PET;
D O I
10.1088/1748-0221/12/03/P03001
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Apixelated cadmium zinc telluride (CZT) detector has been characterised for the purpose of developing a quantitative single photon emission computed tomography (SPECT) system for dosimetry of molecular radiotherapy (MRT). This is the aim of the Dosimetric Imaging with CZT (DEPICT) project, which is a collaboration between theUniversity of Liverpool, The Royal Marsden Hospital, The Royal Liverpool and Broadgreen University Hospital, and the commercial partner Kromek. CZT is a direct band gap semiconductor with superior energy resolution and stopping power compared to scintillator detectors used in current SPECT systems. The inherent detector properties have been investigated and operational parameters such as bias voltage and peaking time have been selected to optimise the performance of the system. Good energy resolution is required to discriminate gamma-rays that are scattered as they are emitted from the body and within the collimator, and high photon throughput is essential due to the high activities of isotopes administered in MRT. The system has an average measured electronic noise of 3.31 keV full width at half maximum (FWHM), determined through the use of an internal pulser. The energy response of the system was measured across the energy region of interest 59.5 keV to 364.5 keV and found to be linear. The reverse bias voltage and peaking time producing the optimum FWHM and maximum photon throughput were 600 V and 0.5 mu s respectively. The average dead time of the system was measured as 4.84 mu s and charge sharing was quantified to be 0.71% at 59.5 keV. A pixel sensitivity calibration map was created and planar images of the medical imaging isotopes Tc-99m and I-123 were acquired by coupling the device to a prototype collimator, thereby demonstrating the suitability of the detector for the DEPICT project.
引用
收藏
页数:17
相关论文
共 50 条
  • [1] Characterisation of a synthetic diamond detector for end-to-end dosimetry in stereotactic body radiotherapy and radiosurgery
    Shaw, Maddison
    Lye, Jessica
    Alves, Andrew
    Keehan, Stephanie
    Lehmann, Joerg
    Hanlon, Maximilian
    Kenny, John
    Baines, John
    Porumb, Claudiu
    Geso, Moshi
    Brown, Rhonda
    PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2021, 20 : 40 - 45
  • [2] In Vivo Dosimetry with MOSFET Detector during Radiotherapy
    Cho, Sam Ju
    Kim, Won Taek
    Ki, Yong Gan
    Kwon, Soo Il
    Lee, Sang Hoon
    Do Huh, Hyun
    Cho, Kwang Hwan
    Kwon, Byung Hyun
    Kim, Dong Won
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING 2006, VOL 14, PTS 1-6, 2007, 14 : 1987 - +
  • [3] Traceable dosimetry for Molecular Radiotherapy
    Joulaeizadeh, L.
    Bobin, C.
    Capogre, M.
    Cox, M.
    D'Arienzo, M.
    Johansson, L.
    de Pooter, J.
    Rabus, H.
    Smyth, V.
    Solc, J.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2014, 41 : S221 - S221
  • [4] Clinical investigations of a CVD diamond detector for radiotherapy dosimetry
    Betzel, G. T.
    Lansley, S. P.
    Baluti, F.
    Reinisch, L.
    Meyer, J.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2012, 28 (02): : 144 - 152
  • [5] Dysprosium detector for neutron dosimetry in external beam radiotherapy
    Ostinelli, A.
    Berlusconi, C.
    Conti, V.
    Duchini, M.
    Gelosa, S.
    Guallini, F.
    Vallazza, E.
    Prest, M.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2014, 759 : 92 - 98
  • [6] Detector-Grade CVD Diamond for Radiotherapy Dosimetry
    Lansley, S.
    Betzel, G.
    Mckay, D.
    Meyer, J.
    MEDICAL PHYSICS, 2012, 39 (06) : 3738 - 3738
  • [7] Development of a silicon diode detector for skin dosimetry in radiotherapy
    Vicoroski, Nikolina
    Espinoza, Anthony
    Duncan, Mitchell
    Oborn, Bradley M.
    Carolan, Martin
    Metcalfe, Peter
    Menichelli, David
    Perevertaylo, Vladimir L.
    Lerch, Michael L. F.
    Rosenfeld, Anatoly B.
    Petasecca, Marco
    MEDICAL PHYSICS, 2017, 44 (10) : 5402 - 5412
  • [8] The NUKDOS Software for Dosimetry in Molecular Radiotherapy
    Kletting, P.
    Schimmel, S.
    Haenscheid, H.
    Fernandez, M.
    Broeer, J.
    Nosske, D.
    Lassmann, M.
    Glatting, G.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2013, 40 : S175 - S175
  • [9] Clinical perspectives on dosimetry in molecular radiotherapy
    Davis, Lauramay
    Elmaraghi, Caroline
    Buscombe, John R.
    Gaze, Mark N.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2023, 114
  • [10] Time to demand dosimetry for molecular radiotherapy?
    McGowan, D. R.
    Guy, M. J.
    BRITISH JOURNAL OF RADIOLOGY, 2015, 88 (1047):