Albuterol delivery by metered-dose inhaler in a pediatric high-frequency oscillatory ventilation model

被引:16
|
作者
Garner, SS
Wiest, DB
Bradley, JW
机构
[1] Med Univ S Carolina, Dept Pharmaceut Sci, Charleston, SC 29425 USA
[2] Med Univ S Carolina, Dept Pediat, Charleston, SC 29425 USA
[3] Med Univ S Carolina, Dept Pediat Resp Care, Charleston, SC 29425 USA
关键词
aerosol drug therapy; aerosols; ventilator; albuterol; bronchodilator agents; children; intratracheal intubation; drug delivery systems; inhalation administration;
D O I
10.1097/00003246-200006000-00070
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objectives: To assess albuterol delivery by metered-dose inhaler (MDI) in a pediatric lung model ventilated by high-frequency oscillatory ventilation (HFOV). The percentage albuterol dose lost in the circuit's expiratory limb and the effects of operating frequency, inspiratory time, and use of a spacer were also determined. Design: Prospective in vitro laboratory study. Setting: Research laboratory. Interventions: A model consisting of a HFOV and circuit, 4.5-mm endotracheal tube, and lung simulator was assembled. Ventilator settings were the following: humidified FIO2 of 1.0; mean airway pressure of 28 cm H2O; operating frequency of 10 Hz; pressure amplitude of 55 cm H2O; bias gas flow to maintain mean airway pressure; 30% inspiratory time; and temperature of 35 degrees C (95 degrees F). Lung simulator compliance and resistance values were consistent with pediatric patients with pulmonary disease. A total of ten MDI canisters were used to administer 2000 mu g of albuterol with a spacer. Circuit filters placed proximal to the lung simulator and in the circuit's expiratory limb collected albuterol exiting the endotracheal tube and any albuterol lost, respectively. Filters were rinsed with water and albuterol concentrations determined by high performance liquid chromatography. Albuterol administration was repeated at operating frequencies of 5 and 15 Hz, inspiratory times of 40% and 50%, and with an actuator instead of a spacer. Each test condition was repeated ten times. Analysis of variance or Student's t-test was used to determine significant differences in albuterol delivered or lost among the operating frequencies and inspiratory times, and between the spacer and actuator. Measurements and Main Results: Albuterol delivery to the lung simulator was <1% of the administered dose regardless of the operating frequency, inspiratory time, or use of a spacer or actuator. Albuterol lost in the expiratory limb ranged from 3.28% to 14.89% of the administered dose. Conclusions: These in vitro results suggest albuterol delivery by MDI in a pediatric model of HFOV is negligible, regardless of the operating frequency, inspiratory time, or use of a spacer or actuator.
引用
收藏
页码:2086 / 2089
页数:4
相关论文
共 50 条
  • [41] High-frequency oscillatory ventilation in pediatric patients
    Duval, ELIM
    Markhorst, DG
    Gemke, RJBJ
    van Vught, AJ
    NETHERLANDS JOURNAL OF MEDICINE, 2000, 56 (05): : 177 - 185
  • [42] Pilot study of bronchodilator response to inhaled albuterol delivered by metered-dose inhaler and a novel dry powder inhaler
    Kemp, JP
    Hill, MR
    Vaughan, LM
    Meltzer, EO
    Welch, MJ
    Ostrom, NK
    ANNALS OF ALLERGY ASTHMA & IMMUNOLOGY, 1997, 79 (04) : 322 - 326
  • [43] Factors Determining In Vitro Lung Deposition of Albuterol Aerosol Delivered by Ventolin Metered-Dose Inhaler
    Biswas, Rajoshi
    Hanania, Nicola A.
    Sabharwal, Ashutosh
    JOURNAL OF AEROSOL MEDICINE AND PULMONARY DRUG DELIVERY, 2017, 30 (04) : 256 - 266
  • [44] A pilot study of nicotine delivery to smokers from a metered-dose inhaler
    Caldwell, Brent
    Dickson, Stuart
    Burgess, Carl
    Siebers, Robert
    Mala, Sima
    Parkes, Adrienne
    Crane, Julian
    NICOTINE & TOBACCO RESEARCH, 2009, 11 (04) : 342 - 347
  • [45] BRONCHODILATOR DELIVERY BY METERED-DOSE INHALER IN VENTILATOR-SUPPORTED PATIENTS
    DHAND, R
    JUBRAN, A
    TOBIN, MJ
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1995, 151 (06) : 1827 - 1833
  • [46] A COMPARISON OF ALBUTEROL ADMINISTERED BY METERED-DOSE INHALER (AND HOLDING CHAMBER) OR WET NEBULIZER IN ACUTE ASTHMA
    COLACONE, A
    AFILALO, M
    WOLKOVE, N
    KREISMAN, H
    CHEST, 1993, 104 (03) : 835 - 841
  • [47] COMPARISON OF METERED-DOSE INHALER AND ORAL-ADMINISTRATION OF ALBUTEROL IN THE OUTPATIENT TREATMENT OF INFANTS AND CHILDREN
    BARTFIELD, JM
    BOENAU, IB
    LOZON, J
    RACCIOROBAK, N
    AMERICAN JOURNAL OF EMERGENCY MEDICINE, 1995, 13 (03): : 375 - 378
  • [48] OROPHARYNGEAL DEPOSITION AND DELIVERY ASPECTS OF METERED-DOSE INHALER AEROSOLS - REPLY
    KIM, CS
    ELDRIDGE, M
    SACKNER, MA
    AMERICAN REVIEW OF RESPIRATORY DISEASE, 1988, 137 (04): : 986 - 986
  • [49] High-dose albuterol by metered-dose inhaler through an asthma spacer device in wheezy infants and young children.
    Ploin, D
    Chapuis, FR
    Stamm, D
    Robert, J
    David, L
    Chatelain, PG
    Dutau, G
    Floret, D
    REVUE FRANCAISE D ALLERGOLOGIE ET D IMMUNOLOGIE CLINIQUE, 2001, 41 (02): : 155 - 164
  • [50] Albuterol via metered-dose inhaler in children: Lower doses are effective, and higher doses are safe
    Muchao, Fabio Pereira
    Miguita e Souza, Juliana
    Cavalcante Torres, Helida Conceicao
    De Lalibera, Isabella Batista
    de Souza, Andrea Vieira
    Rodrigues, Joaquim Carlos
    Schvartsman, Claudio
    Ribeiro Ferreira da Silva Filho, Luiz Vicente
    PEDIATRIC PULMONOLOGY, 2016, 51 (11) : 1122 - 1130