Albuterol delivery by metered-dose inhaler in a pediatric high-frequency oscillatory ventilation model

被引:16
|
作者
Garner, SS
Wiest, DB
Bradley, JW
机构
[1] Med Univ S Carolina, Dept Pharmaceut Sci, Charleston, SC 29425 USA
[2] Med Univ S Carolina, Dept Pediat, Charleston, SC 29425 USA
[3] Med Univ S Carolina, Dept Pediat Resp Care, Charleston, SC 29425 USA
关键词
aerosol drug therapy; aerosols; ventilator; albuterol; bronchodilator agents; children; intratracheal intubation; drug delivery systems; inhalation administration;
D O I
10.1097/00003246-200006000-00070
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objectives: To assess albuterol delivery by metered-dose inhaler (MDI) in a pediatric lung model ventilated by high-frequency oscillatory ventilation (HFOV). The percentage albuterol dose lost in the circuit's expiratory limb and the effects of operating frequency, inspiratory time, and use of a spacer were also determined. Design: Prospective in vitro laboratory study. Setting: Research laboratory. Interventions: A model consisting of a HFOV and circuit, 4.5-mm endotracheal tube, and lung simulator was assembled. Ventilator settings were the following: humidified FIO2 of 1.0; mean airway pressure of 28 cm H2O; operating frequency of 10 Hz; pressure amplitude of 55 cm H2O; bias gas flow to maintain mean airway pressure; 30% inspiratory time; and temperature of 35 degrees C (95 degrees F). Lung simulator compliance and resistance values were consistent with pediatric patients with pulmonary disease. A total of ten MDI canisters were used to administer 2000 mu g of albuterol with a spacer. Circuit filters placed proximal to the lung simulator and in the circuit's expiratory limb collected albuterol exiting the endotracheal tube and any albuterol lost, respectively. Filters were rinsed with water and albuterol concentrations determined by high performance liquid chromatography. Albuterol administration was repeated at operating frequencies of 5 and 15 Hz, inspiratory times of 40% and 50%, and with an actuator instead of a spacer. Each test condition was repeated ten times. Analysis of variance or Student's t-test was used to determine significant differences in albuterol delivered or lost among the operating frequencies and inspiratory times, and between the spacer and actuator. Measurements and Main Results: Albuterol delivery to the lung simulator was <1% of the administered dose regardless of the operating frequency, inspiratory time, or use of a spacer or actuator. Albuterol lost in the expiratory limb ranged from 3.28% to 14.89% of the administered dose. Conclusions: These in vitro results suggest albuterol delivery by MDI in a pediatric model of HFOV is negligible, regardless of the operating frequency, inspiratory time, or use of a spacer or actuator.
引用
收藏
页码:2086 / 2089
页数:4
相关论文
共 50 条
  • [31] Efficacy of fluticasone metered-dose inhaler and dry powder inhaler for pediatric asthma
    Miyahara, Hiroaki
    Korematsu, Seigo
    Nagakura, Tomokazu
    Izumi, Tatsuro
    PEDIATRICS INTERNATIONAL, 2008, 50 (01) : 103 - 108
  • [32] OROPHARYNGEAL DEPOSITION AND DELIVERY ASPECTS OF METERED-DOSE INHALER AEROSOLS
    GONDA, I
    AMERICAN REVIEW OF RESPIRATORY DISEASE, 1988, 137 (04): : 985 - 986
  • [33] Delivery of Epinephrine by Metered-Dose Inhaler for the Treatment of Croup in Children
    Kahne, K.
    Krief, W.
    Victoria, P.
    Dumont, O.
    ANNALS OF EMERGENCY MEDICINE, 2022, 80 (04) : S111 - S111
  • [34] Volume and Pressure Delivery During Pediatric High-Frequency Oscillatory Ventilation
    Wong, Ronald
    Deakers, Timothy
    Hotz, Justin
    Khemani, Robinder G.
    Ross, Patrick A.
    Newth, Christopher J.
    PEDIATRIC CRITICAL CARE MEDICINE, 2017, 18 (04) : E189 - E194
  • [35] EXPERIENCE WITH A METERED-DOSE INHALER WITH A SPACER IN THE PEDIATRIC EMERGENCY DEPARTMENT
    BENTON, G
    THOMAS, RC
    NICKERSON, BG
    MCQUITTY, JC
    OKIKAWA, J
    AMERICAN JOURNAL OF DISEASES OF CHILDREN, 1989, 143 (06): : 678 - 681
  • [36] OROPHARYNGEAL DEPOSITION AND DELIVERY ASPECTS OF METERED-DOSE INHALER AEROSOLS
    KIM, CS
    ELDRIDGE, MA
    SACKNER, MA
    AMERICAN REVIEW OF RESPIRATORY DISEASE, 1987, 135 (01): : 157 - 164
  • [37] COMPARISON OF THE BRONCHODILATOR RESPONSE TO ALBUTEROL ADMINISTERED BY THE OPTIHALER, THE AEROCHAMBER, OR BY METERED-DOSE INHALER ALONE
    NELSON, HS
    LOFFERT, DT
    ANNALS OF ALLERGY, 1994, 72 (04): : 337 - 340
  • [38] ALBUTEROL ADMINISTERED BY METERED-DOSE INHALER AND SPACER TO YOUNG-CHILDREN WITH WHEEZING - REPLY
    HICKEY, RW
    GOCHMAN, RF
    CHANDE, V
    DAVIS, HW
    ARCHIVES OF PEDIATRICS & ADOLESCENT MEDICINE, 1994, 148 (12): : 1353 - 1354
  • [39] Automatic replacement of albuterol nebulizer therapy by metered-dose inhaler and valved holding chamber
    Hendeles, L
    Hatton, RC
    Coons, TJ
    Carlson, L
    AMERICAN JOURNAL OF HEALTH-SYSTEM PHARMACY, 2005, 62 (10) : 1053 - 1061
  • [40] A comparison of drug delivery from a metered-dose inhaler plus an inspiratory flow control device with a metered-dose inhaler plus a spacer device
    Kanner, RE
    Kanter, LJ
    Dwork, P
    JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY, 1997, 99 (06) : 853 - 854