Albuterol delivery by metered-dose inhaler in a pediatric high-frequency oscillatory ventilation model

被引:16
|
作者
Garner, SS
Wiest, DB
Bradley, JW
机构
[1] Med Univ S Carolina, Dept Pharmaceut Sci, Charleston, SC 29425 USA
[2] Med Univ S Carolina, Dept Pediat, Charleston, SC 29425 USA
[3] Med Univ S Carolina, Dept Pediat Resp Care, Charleston, SC 29425 USA
关键词
aerosol drug therapy; aerosols; ventilator; albuterol; bronchodilator agents; children; intratracheal intubation; drug delivery systems; inhalation administration;
D O I
10.1097/00003246-200006000-00070
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objectives: To assess albuterol delivery by metered-dose inhaler (MDI) in a pediatric lung model ventilated by high-frequency oscillatory ventilation (HFOV). The percentage albuterol dose lost in the circuit's expiratory limb and the effects of operating frequency, inspiratory time, and use of a spacer were also determined. Design: Prospective in vitro laboratory study. Setting: Research laboratory. Interventions: A model consisting of a HFOV and circuit, 4.5-mm endotracheal tube, and lung simulator was assembled. Ventilator settings were the following: humidified FIO2 of 1.0; mean airway pressure of 28 cm H2O; operating frequency of 10 Hz; pressure amplitude of 55 cm H2O; bias gas flow to maintain mean airway pressure; 30% inspiratory time; and temperature of 35 degrees C (95 degrees F). Lung simulator compliance and resistance values were consistent with pediatric patients with pulmonary disease. A total of ten MDI canisters were used to administer 2000 mu g of albuterol with a spacer. Circuit filters placed proximal to the lung simulator and in the circuit's expiratory limb collected albuterol exiting the endotracheal tube and any albuterol lost, respectively. Filters were rinsed with water and albuterol concentrations determined by high performance liquid chromatography. Albuterol administration was repeated at operating frequencies of 5 and 15 Hz, inspiratory times of 40% and 50%, and with an actuator instead of a spacer. Each test condition was repeated ten times. Analysis of variance or Student's t-test was used to determine significant differences in albuterol delivered or lost among the operating frequencies and inspiratory times, and between the spacer and actuator. Measurements and Main Results: Albuterol delivery to the lung simulator was <1% of the administered dose regardless of the operating frequency, inspiratory time, or use of a spacer or actuator. Albuterol lost in the expiratory limb ranged from 3.28% to 14.89% of the administered dose. Conclusions: These in vitro results suggest albuterol delivery by MDI in a pediatric model of HFOV is negligible, regardless of the operating frequency, inspiratory time, or use of a spacer or actuator.
引用
收藏
页码:2086 / 2089
页数:4
相关论文
共 50 条
  • [21] First generic of Proventil HFA (albuterol sulfate) metered-dose inhaler
    不详
    NURSE PRACTITIONER, 2020, 45 (08): : 56 - 56
  • [22] TREATMENT OF BRONCHOSPASM BY METERED-DOSE INHALER ALBUTEROL IN MECHANICALLY VENTILATED PATIENTS
    MANTHOUS, CA
    CHATILA, W
    SCHMIDT, GA
    HALL, JB
    CHEST, 1995, 107 (01) : 210 - 213
  • [23] Paradoxical bronchoconstriction with albuterol administered by metered-dose inhaler and nebulizer solution
    Spooner, LM
    Olin, JL
    ANNALS OF PHARMACOTHERAPY, 2005, 39 (11) : 1924 - 1927
  • [24] Comparing the delivery of albuterol metered-dose inhaler via an adapter and spacer device in an in vitro infant ventilator lung model
    Avent, ML
    Gal, P
    Ransom, JL
    Brown, YL
    Hansen, CJ
    ANNALS OF PHARMACOTHERAPY, 1999, 33 (02) : 141 - 143
  • [25] The conversion to metered-dose inhaler with valved holding chamber to administer inhaled albuterol: A pediatric hospital experience
    Salyer, John W.
    DiBlasi, Robert M.
    Crotwell, Dave N.
    Cowan, Charles A.
    Carter, Edward R.
    RESPIRATORY CARE, 2008, 53 (03) : 338 - 345
  • [26] ARE ALBUTEROL (A) AND PIRBUTEROL (P) DELIVERED BY METERED-DOSE INHALER (MDI) THERAPEUTICALLY EQUIVALENT
    NELSON, JS
    AHRENS, RC
    ECKLUND, P
    LUX, C
    JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY, 1992, 89 (01) : 345 - 345
  • [27] ALBUTEROL ADMINISTERED BY METERED-DOSE INHALER AND SPACER TO YOUNG-CHILDREN WITH WHEEZING
    CARTER, LTCE
    ARCHIVES OF PEDIATRICS & ADOLESCENT MEDICINE, 1994, 148 (12): : 1352 - 1353
  • [28] RELATIVE POTENCY OF AEROSOL ALBUTEROL ADMINISTERED BY METERED-DOSE INHALER AND NEBULIZER SOLUTION
    HOPPE, MM
    BLAKE, KV
    HENDELES, L
    HARMAN, E
    PHARMACOTHERAPY, 1988, 8 (02): : 130 - 130
  • [29] A low dose of albuterol by metered-dose inhaler with a spacer was as effective as higher doses by metered-dose inhaler or low doses by nebulizer in children with mild acute asthma - Commentary
    Horner, SD
    WESTERN JOURNAL OF MEDICINE, 2000, 172 (04): : 247 - 247
  • [30] PRESSURIZED METERED DOSE INHALER ALBUTEROL DELIVERY DURING NASAL HIGH FLOW THERAPY
    Reminiac, Francois
    Thomas, Bocar
    Landel, Cassandre
    Gensburger, Samuel
    Philippe, Marion
    Mordier, Lydiane
    Cabrera, Maria
    Le Pennec, Deborah
    Vecellio, Laurent
    Ehrmann, Stephan
    JOURNAL OF AEROSOL MEDICINE AND PULMONARY DRUG DELIVERY, 2017, 30 (03) : 23 - 23