Albuterol delivery by metered-dose inhaler in a pediatric high-frequency oscillatory ventilation model

被引:16
|
作者
Garner, SS
Wiest, DB
Bradley, JW
机构
[1] Med Univ S Carolina, Dept Pharmaceut Sci, Charleston, SC 29425 USA
[2] Med Univ S Carolina, Dept Pediat, Charleston, SC 29425 USA
[3] Med Univ S Carolina, Dept Pediat Resp Care, Charleston, SC 29425 USA
关键词
aerosol drug therapy; aerosols; ventilator; albuterol; bronchodilator agents; children; intratracheal intubation; drug delivery systems; inhalation administration;
D O I
10.1097/00003246-200006000-00070
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objectives: To assess albuterol delivery by metered-dose inhaler (MDI) in a pediatric lung model ventilated by high-frequency oscillatory ventilation (HFOV). The percentage albuterol dose lost in the circuit's expiratory limb and the effects of operating frequency, inspiratory time, and use of a spacer were also determined. Design: Prospective in vitro laboratory study. Setting: Research laboratory. Interventions: A model consisting of a HFOV and circuit, 4.5-mm endotracheal tube, and lung simulator was assembled. Ventilator settings were the following: humidified FIO2 of 1.0; mean airway pressure of 28 cm H2O; operating frequency of 10 Hz; pressure amplitude of 55 cm H2O; bias gas flow to maintain mean airway pressure; 30% inspiratory time; and temperature of 35 degrees C (95 degrees F). Lung simulator compliance and resistance values were consistent with pediatric patients with pulmonary disease. A total of ten MDI canisters were used to administer 2000 mu g of albuterol with a spacer. Circuit filters placed proximal to the lung simulator and in the circuit's expiratory limb collected albuterol exiting the endotracheal tube and any albuterol lost, respectively. Filters were rinsed with water and albuterol concentrations determined by high performance liquid chromatography. Albuterol administration was repeated at operating frequencies of 5 and 15 Hz, inspiratory times of 40% and 50%, and with an actuator instead of a spacer. Each test condition was repeated ten times. Analysis of variance or Student's t-test was used to determine significant differences in albuterol delivered or lost among the operating frequencies and inspiratory times, and between the spacer and actuator. Measurements and Main Results: Albuterol delivery to the lung simulator was <1% of the administered dose regardless of the operating frequency, inspiratory time, or use of a spacer or actuator. Albuterol lost in the expiratory limb ranged from 3.28% to 14.89% of the administered dose. Conclusions: These in vitro results suggest albuterol delivery by MDI in a pediatric model of HFOV is negligible, regardless of the operating frequency, inspiratory time, or use of a spacer or actuator.
引用
收藏
页码:2086 / 2089
页数:4
相关论文
共 50 条
  • [1] Albuterol delivery by metered-dose inhaler in a mechanically ventilated pediatric lung model
    Garner, SS
    Wiest, DB
    Bradley, JW
    Lesher, BA
    Habib, DM
    CRITICAL CARE MEDICINE, 1996, 24 (05) : 870 - 874
  • [2] ALBUTEROL DELIVERY BY METERED-DOSE INHALER WITH A PEDIATRIC MECHANICAL VENTILATORY CIRCUIT MODEL
    GARNER, SS
    WIEST, DB
    BRADLEY, JW
    PHARMACOTHERAPY, 1994, 14 (02): : 210 - 214
  • [3] ALBUTEROL DELIVERY IN A MODEL OF MECHANICAL VENTILATION - COMPARISON OF METERED-DOSE INHALER AND NEBULIZER EFFICIENCY
    DIOT, P
    MORRA, L
    SMALDONE, GC
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1995, 152 (04) : 1391 - 1394
  • [4] Effect of heliox on albuterol delivery by metered-dose inhaler in pediatric in vitro models of mechanical ventilation
    Garner, Sandra S.
    Wiest, Donald B.
    Stevens, Charles E.
    Habib, David M.
    PHARMACOTHERAPY, 2006, 26 (10): : 1396 - 1402
  • [5] Bronchodilator delivery with metered-dose inhaler during mechanical ventilation
    Georgopoulos, D
    Mouloudi, E
    Kondili, E
    Klimathianaki, M
    CRITICAL CARE, 2000, 4 (04): : 227 - 234
  • [6] Bronchodilator delivery with metered-dose inhaler during mechanical ventilation
    Dimitris Georgopoulos
    Eleni Mouloudi
    Eumorfia Kondili
    Maria Klimathianaki
    Critical Care, 4
  • [7] Albuterol delivery via metered dose inhaler in a spontaneously breathing pediatric tracheostomy model
    Berlinski, Ariel
    Chavez, Alma
    PEDIATRIC PULMONOLOGY, 2013, 48 (10) : 1026 - 1034
  • [8] Aerosol delivery from a metered-dose inhaler during mechanical ventilation - An in vitro model
    Fink, JB
    Dhand, R
    Duarte, AG
    Jenne, JW
    Tobin, MJ
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1996, 154 (02) : 382 - 387
  • [9] Comparative efficacy and safety of albuterol sulfate spiros inhaler and albuterol metered-dose inhaler in asthma
    Nelson, H
    Kemp, JP
    Bieler, S
    Vaughan, LM
    Hill, MR
    CHEST, 1999, 115 (02) : 329 - 335
  • [10] A CLINICAL COMPARISON OF TERBUTALINE WITH ALBUTEROL ADMINISTERED BY METERED-DOSE INHALER
    MUNZENBERGER, PJ
    PAPAIOANOU, HA
    MASSOUD, N
    ANNALS OF ALLERGY, 1989, 62 (02): : 107 - 110