Automatic measurement of electron-beam diameter and astigmatism: BEAMETR

被引:6
|
作者
Babin, S. [1 ]
Gaevski, M. [2 ]
Joy, D. [3 ,4 ]
Machin, M. [1 ]
Martynov, A. [1 ]
机构
[1] Abeam Technol, 5286 Dunnigan Ct, Castro Valley, CA 94546 USA
[2] Univ South Carolina, Columbia, SC 29208 USA
[3] Oak Ridge Natl Lab, Oak Ridge, TN 37381 USA
[4] Univ Tennessee, EM Facil, Knoxville, TN 37996 USA
关键词
Electron probe diameter; Software; SEM resolution;
D O I
10.1016/j.phpro.2008.07.085
中图分类号
O412 [相对论、场论]; O572.2 [粒子物理学];
学科分类号
摘要
Beam size is one of the major characteristics of any electron beam system. Accuracy and resolution of SEM and an EBL system directly depend on beam diameter; it should be monitored and tuned frequently. Currently used methods are not accurate and are operator dependent. A technique is described to determine beam size using an automatic procedure. In the developed method, a specially designed and fabricated test pattern is scanned using an e-beam. A spectra of the signal is analyzed; beam diameter is automatically determined using a software program. Results of design, fabrication, and analysis of the beam calibration test pattern are presented. (C) 2008 Elsevier B. V. All rights reserved.
引用
收藏
页码:113 / 118
页数:6
相关论文
共 50 条
  • [41] AUTOMATIC SPECIMEN-TRANSPORT DEVICE FOR ELECTRON-BEAM APPARATUS
    KALDYROV, YA
    KOVAL, BA
    SMIRNOV, OV
    YANKELEVICH, BY
    YANKELEVICH, EB
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 1987, 30 (05) : 1265 - 1269
  • [42] Electron-beam diagnostic for space-charge measurement of an ion beam
    Roy, PK
    Yu, SS
    Henestroza, E
    Eylon, S
    Shuman, DB
    Ludvig, J
    Bieniosek, FM
    Waldron, WL
    Greenway, WG
    Vanecek, DL
    Hannink, R
    Amezcua, M
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2005, 76 (02): : 023301 - 1
  • [43] DIRECT MEASUREMENT OF CONTAMINATION AND ETCHING RATES IN AN ELECTRON-BEAM
    EGERTON, RF
    ROSSOUW, CJ
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 1976, 9 (04) : 659 - 663
  • [44] ALGORITHMIC REDUCTION OF BEAM PARAMETER MEASUREMENT ERRORS BY ELECTRON-BEAM DIAGNOSIS
    AGIBALOV, VA
    SHESTAK, VP
    MEASUREMENT TECHNIQUES USSR, 1991, 34 (06): : 626 - 630
  • [45] MEASUREMENT OF THE ENERGY-SPECTRUM OF A FAST ELECTRON-BEAM
    YAMAMOTO, C
    NUCLEAR SCIENCE AND ENGINEERING, 1979, 72 (02) : 262 - 265
  • [46] MEASUREMENT OF THE LONGITUDINAL PARAMETERS OF AN ELECTRON-BEAM IN A STORAGE RING
    KRINSKY, S
    FRONTIERS OF PARTICLE BEAMS : OBSERVATION, DIAGNOSIS AND CORRECTION, 1989, 343 : 150 - 166
  • [47] AURORA ELECTRON-BEAM ANODE DEPTH DOSE MEASUREMENT
    LITTLE, R
    GRAYBILL, S
    SAZAMA, J
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1973, 18 (10): : 1310 - 1310
  • [48] SIMULTANEOUS TEMPERATURE MEASUREMENT AND CONTROL FOR ELECTRON-BEAM FURNACES
    HURLEY, D
    OBLINGER, CJ
    ROLINSKI, EJ
    JOURNAL OF VACUUM SCIENCE & TECHNOLOGY, 1971, 8 (02): : 461 - &
  • [49] ELECTRON-BEAM PROFILE MEASUREMENT BY USING TL SHEETS
    WADA, T
    TAKAHASHI, N
    YAMAMOTO, I
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1987, 261 (03): : 368 - 372
  • [50] USE OF A THERMOLUMINESCENCE SHEET FOR ELECTRON-BEAM PROFILE MEASUREMENT
    MIONO, S
    NUCLEAR INSTRUMENTS & METHODS, 1975, 128 (01): : 173 - 174