Automatic measurement of electron-beam diameter and astigmatism: BEAMETR

被引:6
|
作者
Babin, S. [1 ]
Gaevski, M. [2 ]
Joy, D. [3 ,4 ]
Machin, M. [1 ]
Martynov, A. [1 ]
机构
[1] Abeam Technol, 5286 Dunnigan Ct, Castro Valley, CA 94546 USA
[2] Univ South Carolina, Columbia, SC 29208 USA
[3] Oak Ridge Natl Lab, Oak Ridge, TN 37381 USA
[4] Univ Tennessee, EM Facil, Knoxville, TN 37996 USA
关键词
Electron probe diameter; Software; SEM resolution;
D O I
10.1016/j.phpro.2008.07.085
中图分类号
O412 [相对论、场论]; O572.2 [粒子物理学];
学科分类号
摘要
Beam size is one of the major characteristics of any electron beam system. Accuracy and resolution of SEM and an EBL system directly depend on beam diameter; it should be monitored and tuned frequently. Currently used methods are not accurate and are operator dependent. A technique is described to determine beam size using an automatic procedure. In the developed method, a specially designed and fabricated test pattern is scanned using an e-beam. A spectra of the signal is analyzed; beam diameter is automatically determined using a software program. Results of design, fabrication, and analysis of the beam calibration test pattern are presented. (C) 2008 Elsevier B. V. All rights reserved.
引用
收藏
页码:113 / 118
页数:6
相关论文
共 50 条
  • [31] DETECTOR-OBJECTIVE FOR ELECTRON-BEAM MEASUREMENT
    WOLF, B
    ZACH, J
    ROSE, H
    EUROPEAN JOURNAL OF CELL BIOLOGY, 1987, 44 : 62 - 62
  • [32] A SIMPLE METHOD FOR THE MEASUREMENT OF ELECTRON-BEAM ENERGY
    KNIZHNIK, EI
    MOSKALEV, VA
    ONISKO, AD
    SOVIET ATOMIC ENERGY, 1986, 60 (03): : 279 - 281
  • [33] THE AUTOMATIC-CONTROL OF ELECTRON-BEAM WELDING EQUIPMENT
    LANKIN, YN
    ANISHCHENKO, VA
    AUTOMATIC WELDING USSR, 1980, 33 (07): : 30 - 32
  • [34] EXPERIMENTAL SCANNING ELECTRON-BEAM AUTOMATIC REGISTRATION SYSTEM
    WILSON, AD
    CHANG, THP
    KERN, A
    JOURNAL OF VACUUM SCIENCE & TECHNOLOGY, 1975, 12 (06): : 1240 - 1245
  • [35] Beam formation in electron-beam welding - Measurement and mathematical model
    Dilthey, Ulrich
    Goumeniouk, Andrei
    Welding and Cutting, 2002, 54 (06): : 294 - 299
  • [36] MEASUREMENT OF FUNGICIDE SMOKE APPLICATION BY ELECTRON-BEAM ANALYSIS
    KRAUSE, CR
    POWELL, CC
    SCANNING MICROSCOPY, 1989, 3 (01) : 243 - 248
  • [37] PASSIVE CALORIMETER FOR PULSED ELECTRON-BEAM ENERGY MEASUREMENT
    STEPHENS, HP
    HECKMAN, RC
    DONALDSON, AB
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1972, 43 (04): : 614 - +
  • [38] MEASUREMENT OF FREQUENCY OF COHERENT OSCILLATIONS OF AN ELECTRON-BEAM IN A SYNCHROTRON
    VIZIR, BA
    NIKITIN, MM
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES-USSR, 1971, 14 (05): : 1300 - &
  • [39] Noninvasive measurement of electron-beam size with diamagnetic loops
    Ekdahl, C
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2001, 72 (07): : 2909 - 2914
  • [40] ELECTRON-BEAM MEASUREMENT OF THE ROTATIONAL TRANSFORM IN THE ENCORE TOKAMAK
    FREDRICKSON, ED