A disposable multianalyte electrochemical immunosensor array for automated simultaneous determination of tumor markers

被引:95
|
作者
Wu, Jie
Yan, Feng
Tang, Jinhai
Zhai, Chun
Ju, Huangxian [1 ]
机构
[1] Nanjing Univ, Dept Chem, Minist Educ China, Key Lab Analyt Chem Life Sci, Nanjing 210093, Peoples R China
[2] Jiangsu Inst Canc Prevent & Cure, Nanjing 210009, Peoples R China
关键词
D O I
10.1373/clinchem.2007.086975
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: Automated and convenient multianalyte detection with high throughput is increasingly needed in clinical diagnosis. We developed a disposable 4-by-2 array for programmed simultaneous amperometric immunoassay of 4 tumor markers. Methods: We used a screen-printed technique, 1-step immobilization method, and flow injection technique. We immobilized carcinoembryonic antigen, alpha-fetoprotein, beta-human choriogonadotropin, and carcinoma antigen 125 as model analytes in a redox mediator- grafted, biopolymer-modified, screen-printed carbon electrode array to capture corresponding horseradish peroxidase-labeled antibodies in competitive immunoreactions. The simultaneous multianalyte immunoassay was automatically carried out to amperometrically monitor the mediator-catalyzed enzymatic response to hydrogen peroxide, which decreased in proportion to the concentrations of analytes in samples. Results: The multianalyte immunosensor array had a throughput of 60 samples/h and allowed simultaneous detection of carcinoembryonic antigen, a-fetoprotein, beta-human choriogonadotropin, and carcinoma antigen 125 in clinical serum samples with concentrations up to 188 mu g/L, 250 mu g/L, 266 IU/L, and 334 kIU/L, respectively. The detection limits (limits of the blank, mean of blank plus 3 SD) were 1.1 mu g/L, 1.7 mu g/L, 1.2 IU/L, and 1.7 kIU/L. The inter- and intraassay imprecision (CVs) of the immunosensor arrays were < 7.8% and < 9.0%, respectively. The immunosensor arrays were stable for 28 days. Conclusions: This newly constructed immunosensor array provides a simple, automated, simultaneous multianalyte immunoassay with high throughput, short analytical time, and sufficiently low detection limits for clinical application. This method offers the capability of miniaturizing the multianalyte detection device. (c) 2007 American Association for Clinical Chemistry.
引用
收藏
页码:1495 / 1502
页数:8
相关论文
共 50 条
  • [1] A disposable two-throughput electrochemical immunosensor chip for simultaneous multianalyte detennination of tumor markers
    Wu, Jie
    Zhang, Zhijie
    Fu, Zhifeng
    Ju, Huangxian
    BIOSENSORS & BIOELECTRONICS, 2007, 23 (01): : 114 - 120
  • [2] Disposable electrochemical immunosensor for simultaneous assay of a panel of breast cancer tumor markers
    Ge, Shenguang
    Yu, Feng
    Ge, Lei
    Yan, Mei
    Yu, Jinghua
    Chen, Dairong
    ANALYST, 2012, 137 (20) : 4727 - 4733
  • [3] Sensitive electrochemical immunosensor array for the simultaneous detection of multiple tumor markers
    Qi, Honglan
    Ling, Chen
    Ma, Qingyun
    Gao, Qiang
    Zhang, Chengxiao
    ANALYST, 2012, 137 (02) : 393 - 399
  • [4] Disposable reagentless electrochemical immunosensor array based on a biopolymer/sol-gel membrane for simultaneous measurement of several tumor markers
    Wu, Jie
    Yan, Feng
    Zhang, Xiaoqing
    Yan, Yuetian
    Tang, Jinhai
    Ju, Huangxian
    CLINICAL CHEMISTRY, 2008, 54 (09) : 1481 - 1488
  • [5] Disposable electrochemical magneto immunosensor for simultaneous simplified calibration and determination of Ochratoxin A in coffee samples
    Jodra, Adrian
    Hervas, Mirian
    Angel Lopez, Miguel
    Escarpa, Alberto
    SENSORS AND ACTUATORS B-CHEMICAL, 2015, 221 : 777 - 783
  • [6] A label-free immunosensor based on graphene nanocomposites for simultaneous multiplexed electrochemical determination of tumor markers
    Jia, Xinle
    Liu, Zhimin
    Liu, Na
    Ma, Zhanfang
    BIOSENSORS & BIOELECTRONICS, 2014, 53 : 160 - 166
  • [7] Disposable electrochemical immunosensor for cortisol determination in human saliva
    Kamarainen, Satu
    Maki, Marianne
    Tolonen, Tiina
    Palleschi, Giuseppe
    Virtanen, Vesa
    Micheli, Laura
    Sesay, Adama Marie
    TALANTA, 2018, 188 : 50 - 57
  • [9] Highly sensitive electrochemical immunosensor for the simultaneous detection of multiple tumor markers for signal amplification
    Wang, Na
    Wang, Jing
    Zhao, Xiaoqing
    Chen, Hou
    Xu, Hui
    Bai, Liangjiu
    Wang, Wenxiang
    Yang, Huawei
    Wei, Donglei
    Yuan, Baiqing
    TALANTA, 2021, 226
  • [10] A disposable electrochemical immunosensor for the determination of leptin in serum and breast milk
    Ojeda, Irene
    Moreno-Guzman, Maria
    Gonzalez-Cortes, Araceli
    Yanez-Sedeno, Paloma
    Pingarron, Jose M.
    ANALYST, 2013, 138 (15) : 4284 - 4291