Body composition by air-displacement plethysmography by using predicted and measured thoracic gas volumes

被引:126
|
作者
McCrory, MA
Molé, PA
Gomez, TD
Dewey, KG
Bernauer, EM
机构
[1] Univ Calif Davis, Dept Nutr, Davis, CA 95616 USA
[2] Univ Calif Davis, Dept Exercise Sci, Davis, CA 95616 USA
关键词
fractional lung volumes; hydrostatic weighing; validity; densitometry; body volume;
D O I
10.1152/jappl.1998.84.4.1475
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
The BOD POD, a new air-displacement plethysmograph for measuring human body composition, utilizes the inverse relationship between pressure and volume (Boyle's law) to measure body volume directly. The quantity of air in the lungs during tidal breathing, the average thoracic gas volume (Vtg), is also measured by the BOD POD by using a standard plethysmographic technique. Alternatively, the BOD POD provides the use of a predicted Vtg (Vtg(pred)). The validity of using Vtg(pred) in place of measured Vtg (Vtg(meas)) to determine the percentage of body fat (%BF) was evaluated in 50 subjects (36 women, 14 men; ages 18-56 yr). There was no significant difference between Vtg(meas) and Vtg(pred) (mean difference +/- SE, 53.5 +/- 63.3 mi) nor in %BF by using Vtg(meas) vs. Vtg(pred) (0.2 +/- 0.2 %BF). On an individual basis, %BF measured by using Vtg(meas) vs. Vtg(pred) differed within +/-2.0% BF for 82% of the subjects; maximum differences were -2.9 to +3.0% BF. For comparison, data from 24 subjects who had undergone hydrostatic weighing were evaluated for the validity of using predicted vs. measured residual lung volume (VRpred VS VRmeas, respectively). Differences between VRmeas and VRpred and in %BF calculated by using VRmeas vs. VRpred were significant (187 +/- 46 mi and 1.4 +/- 0.3% BF, respectively; P < 0.001). On an individual basis, %BF determined by using VRmeas vs. VRpred differed within +/-2.0% BF for 46% of the subjects; maximum differences were -2.9 to +3.8% BF. With respect to %BF measured by air displacement, our findings support the use of Vtg(pred) for group mean comparisons and for purposes such as screening in young to middle-aged individuals. This contrasts with the use of VRpred in hydrostatic weighing, which leads to significant errors in the estimation of %BF. Furthermore, although the use of Vtg(pred) has some application, determining Vtg(meas) is relatively simple in most cases. Therefore, we recommend that the use of Vtg(meas) remain as standard experimental and clinical practice.
引用
收藏
页码:1475 / 1479
页数:5
相关论文
共 50 条
  • [21] Calibration of bioelectrical impedance analysis for body composition assessment in Ethiopian infants using air-displacement plethysmography
    Wibaek, R.
    Kaestel, P.
    Skov, S. R.
    Christensen, D. L.
    Girma, T.
    Wells, J. C. K.
    Friis, H.
    Andersen, G. S.
    EUROPEAN JOURNAL OF CLINICAL NUTRITION, 2015, 69 (10) : 1099 - 1104
  • [22] Air-displacement plethysmography for the measurement of body composition in children aged 6–48 months
    Ryan P. Rosendale
    Cynthia J. Bartok
    Pediatric Research, 2012, 71 : 299 - 304
  • [23] Whole body composition analysis by the bodpod air-displacement plethysmography method in children with phenylketonuria
    Albersen, M.
    Bonthuis, M.
    De Roos, N. M.
    van den Hurk, T. A. M.
    Carbasisus-Weber, E. C.
    Hendriks, M. M. W. D.
    Koning, T. J.
    Visser, G.
    JOURNAL OF INHERITED METABOLIC DISEASE, 2008, 31 : 81 - 81
  • [24] Estimation of the Relative Validity of Assessment of Body Composition by Hydrodensitometry Compared with Air-Displacement Plethysmography
    Knutzen, J.
    Bosy-Westphal, A.
    Maurer, I.
    Borngaesser, J.
    Mueller, M. J.
    AKTUELLE ERNAHRUNGSMEDIZIN, 2008, 33 (05): : 237 - 246
  • [25] Calibration of bioelectrical impedance analysis for body composition assessment in Ethiopian infants using air-displacement plethysmography
    R Wibæk
    P Kæstel
    S R Skov
    D L Christensen
    T Girma
    J C K Wells
    H Friis
    G S Andersen
    European Journal of Clinical Nutrition, 2015, 69 : 1099 - 1104
  • [26] Body-composition assessment via air-displacement plethysmography in adults and children: a review
    Fields, DA
    Goran, MI
    McCrory, MA
    AMERICAN JOURNAL OF CLINICAL NUTRITION, 2002, 75 (03): : 453 - 467
  • [27] Can air-displacement plethysmography replace hydrodensitometry for body composition analysis in children and adults?
    Ellis, KJ
    Pratt, L
    Puyau, M
    Shypailo, R
    Butte, NF
    FASEB JOURNAL, 2001, 15 (05): : A1004 - A1004
  • [28] Predictive model specific to young adults for estimating thoracic gas volume for air-displacement plethysmography
    Ducharme, Jeremy B.
    Hsiao, Yu-Yu
    Gibson, Ann L.
    Mermier, Christine M.
    CLINICAL PHYSIOLOGY AND FUNCTIONAL IMAGING, 2022, 42 (02) : 96 - 103
  • [29] Body composition following stem cell transplant: Comparison of bioimpedance and air-displacement plethysmography
    Hung, Yun-Chi
    Bauer, Judith D.
    Horsely, Pamela
    Ward, Leigh C.
    Bashford, John
    Isenring, Elisabeth A.
    NUTRITION, 2014, 30 (09) : 1000 - 1006
  • [30] Selection of a Thoracic Gas Volume When Using Air Displacement Plethysmography to Assess Longitudinal Body Composition Changes
    Wilson, Patrick B.
    INTERNATIONAL JOURNAL OF SPORT NUTRITION AND EXERCISE METABOLISM, 2017, 27 (06) : 485 - 486