Body composition by air-displacement plethysmography by using predicted and measured thoracic gas volumes

被引:126
|
作者
McCrory, MA
Molé, PA
Gomez, TD
Dewey, KG
Bernauer, EM
机构
[1] Univ Calif Davis, Dept Nutr, Davis, CA 95616 USA
[2] Univ Calif Davis, Dept Exercise Sci, Davis, CA 95616 USA
关键词
fractional lung volumes; hydrostatic weighing; validity; densitometry; body volume;
D O I
10.1152/jappl.1998.84.4.1475
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
The BOD POD, a new air-displacement plethysmograph for measuring human body composition, utilizes the inverse relationship between pressure and volume (Boyle's law) to measure body volume directly. The quantity of air in the lungs during tidal breathing, the average thoracic gas volume (Vtg), is also measured by the BOD POD by using a standard plethysmographic technique. Alternatively, the BOD POD provides the use of a predicted Vtg (Vtg(pred)). The validity of using Vtg(pred) in place of measured Vtg (Vtg(meas)) to determine the percentage of body fat (%BF) was evaluated in 50 subjects (36 women, 14 men; ages 18-56 yr). There was no significant difference between Vtg(meas) and Vtg(pred) (mean difference +/- SE, 53.5 +/- 63.3 mi) nor in %BF by using Vtg(meas) vs. Vtg(pred) (0.2 +/- 0.2 %BF). On an individual basis, %BF measured by using Vtg(meas) vs. Vtg(pred) differed within +/-2.0% BF for 82% of the subjects; maximum differences were -2.9 to +3.0% BF. For comparison, data from 24 subjects who had undergone hydrostatic weighing were evaluated for the validity of using predicted vs. measured residual lung volume (VRpred VS VRmeas, respectively). Differences between VRmeas and VRpred and in %BF calculated by using VRmeas vs. VRpred were significant (187 +/- 46 mi and 1.4 +/- 0.3% BF, respectively; P < 0.001). On an individual basis, %BF determined by using VRmeas vs. VRpred differed within +/-2.0% BF for 46% of the subjects; maximum differences were -2.9 to +3.8% BF. With respect to %BF measured by air displacement, our findings support the use of Vtg(pred) for group mean comparisons and for purposes such as screening in young to middle-aged individuals. This contrasts with the use of VRpred in hydrostatic weighing, which leads to significant errors in the estimation of %BF. Furthermore, although the use of Vtg(pred) has some application, determining Vtg(meas) is relatively simple in most cases. Therefore, we recommend that the use of Vtg(meas) remain as standard experimental and clinical practice.
引用
收藏
页码:1475 / 1479
页数:5
相关论文
共 50 条
  • [31] Monitoring body fat in the elderly: application of air-displacement plethysmography
    Fields, DA
    Hunter, GR
    CURRENT OPINION IN CLINICAL NUTRITION AND METABOLIC CARE, 2004, 7 (01): : 11 - 14
  • [32] Air-displacement plethysmography: here to stay
    Fields, DA
    Higgins, PB
    Radley, D
    CURRENT OPINION IN CLINICAL NUTRITION AND METABOLIC CARE, 2005, 8 (06): : 624 - 629
  • [33] Anthropometry-based prediction of body composition in early infancy compared to air-displacement plethysmography
    Olga, Laurentya
    van Beijsterveldt, Inge A. L. P.
    Hughes, Ieuan A.
    Dunger, David B.
    Ong, Ken K.
    Hokken-Koelega, Anita C. S.
    De Lucia Rolfe, Emanuella
    PEDIATRIC OBESITY, 2021, 16 (11):
  • [34] Air-displacement plethysmography for the measurement of body composition in children aged 6-48 months
    Rosendale, Ryan P.
    Bartok, Cynthia J.
    PEDIATRIC RESEARCH, 2012, 71 (03) : 299 - 304
  • [35] Body composition predicted from skinfolds in African women: a cross-validation study using air-displacement plethysmography and a black-specific equation
    Dioum, A
    Gartner, A
    Maire, B
    Delpeuch, F
    Wade, S
    BRITISH JOURNAL OF NUTRITION, 2005, 93 (06) : 973 - 979
  • [36] Challenges in body composition assessment using air-displacement plethysmography by BOD POD in pediatric and young adult patients
    Bijlsma, Alja
    Beijsterveldt, Inge A. L. P. van
    Vermeulen, Marijn J.
    Beunders, Victoria A. A.
    Dorrepaal, Demi J.
    Boeters, Sanne C. M.
    van den Akker, Erica L. T.
    Vlug, Lotte E.
    de Koning, Barbara A. E.
    Bracke, Katrien F. M.
    Dieleman, Gwen C.
    Scheffers, Linda E.
    Hagenaar, Doesjka A.
    Affourtit, Philine
    Bindels-de Heus, Karen G. C. B.
    Hokken-Koelega, Anita C. S.
    Joosten, Koen F. M.
    CLINICAL NUTRITION, 2023, 42 (09) : 1588 - 1594
  • [37] Body Fat in Children Measured by DXA, Air-Displacement Plethysmography, TBW and Multicomponent Models: A Systematic Review
    Roberta de Vargas Zanini
    Iná S. Santos
    Maria Aurora D. Chrestani
    Denise Petrucci Gigante
    Maternal and Child Health Journal, 2015, 19 : 1567 - 1573
  • [38] Precision of measurement and body size in whole-body air-displacement plethysmography
    JCK Wells
    NJ Fuller
    International Journal of Obesity, 2001, 25 : 1161 - 1167
  • [39] Precision of measurement and body size in whole-body air-displacement plethysmography
    Wells, JCK
    Fuller, NJ
    INTERNATIONAL JOURNAL OF OBESITY, 2001, 25 (08) : 1161 - 1167
  • [40] Body composition measurements by air-displacement plethysmography and underwater weighing: Effects of gastrointestinal contents.
    McCrory, MA
    Fuss, PJ
    Saltzman, E
    Hays, NP
    Roberts, SB
    FASEB JOURNAL, 2000, 14 (04): : A498 - A498