Predictive model specific to young adults for estimating thoracic gas volume for air-displacement plethysmography

被引:1
|
作者
Ducharme, Jeremy B. [1 ]
Hsiao, Yu-Yu [2 ]
Gibson, Ann L. [1 ]
Mermier, Christine M. [1 ]
机构
[1] Univ New Mexico, Dept Hlth Exercise & Sports Sci, Albuquerque, NM 87131 USA
[2] Univ New Mexico, Dept Individual Family & Community Educ, Albuquerque, NM 87131 USA
关键词
BodPod; body composition; lung volume; modeling; prediction; BODY-COMPOSITION; FAT;
D O I
10.1111/cpf.12736
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
Background Thoracic gas volume either measured (mTGV) or predicted by the BodPod (R) (bpTGV) is used during air-displacement plethysmography to obtain a better estimate of percent body fat. Evidence suggests that bpTGV underestimates mTGV for young adults and this is especially evident for young males. Aims We developed, validated, and cross-validated a TGV prediction model (pTGV) for males and females 18-30 years of age to address this underestimation. Materials & Methods Participants (N = 181; 18-30 years) that had their body composition assessed with the BodPod (R) were retrospectively randomly assigned to one of two independent subgroups, a validation (n = 145) or cross-validation (n = 36) sample. Ten iterations of the k-fold validation procedure were performed to assess the internal replicability of pTGV within the validation sample. External replicability of pTGV was evaluated by assessing the difference and standard error of the estimate (SEE) compared to mTGV in the cross-validation group. Results The model using height, sex and body mass yielded the highest adjusted R-2 (0.627) and the lowest SEE (0.56 L): pTGV = 0.615338 x Sex (0 = Female, 1 = Male) + 0.056267 x Height (cm) - 0.011006 x Body Mass (kg) - 5.358839. R-2 remained stable across 10 iterations of the k-fold procedure (average R-2 = 0.64). Differences between pTGV and mTGV were not significantly different than zero for the total cross-validation sample (-0.06 +/- 0.7 L; SEE = 3.0%), for males (-0.11 +/- 0.7 L; SEE = 3.7%), or for females (-0.02 +/- 0.7 L; SEE = 5.3%). Conclusion We recommend that when it is impractical to obtain mTGV, the strong internal and external replicability of the new prediction model supports its use for males and females ages 18-30 years old during air-displacement plethysmography.
引用
收藏
页码:96 / 103
页数:8
相关论文
共 40 条
  • [1] Child-specific thoracic gas volume prediction equations for air-displacement plethysmography
    Fields, DA
    Hull, HR
    Cheline, AJ
    Yao, MJ
    Higgins, PB
    [J]. OBESITY RESEARCH, 2004, 12 (11): : 1797 - 1804
  • [2] Development of child-specific thoracic gas volume prediction equations for use in air-displacement plethysmography
    Fields, D
    Hull, H
    Cheline, AJ
    Yao, MJ
    Higgins, P
    [J]. OBESITY RESEARCH, 2004, 12 : A206 - A206
  • [3] Effects Of Acute Exercise On The Accuracy Of Air-displacement Plethysmography In Young Adults
    Otterstetter, Ronald
    Viar, Jessica
    Naylor, Jonathan
    Krone, Sandra
    Tessmer, Kathryn
    [J]. MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2012, 44 : 796 - 796
  • [4] Changes in thoracic gas volume with air-displacement plethysmography after a weight loss program in overweight and obese women
    Minderico, C. S.
    Silva, A. M.
    Fields, D. A.
    Branco, T. L.
    Martins, S. S.
    Teixeira, P. J.
    Sardinha, L. B.
    [J]. EUROPEAN JOURNAL OF CLINICAL NUTRITION, 2008, 62 (03) : 444 - 450
  • [5] Changes in thoracic gas volume with air-displacement plethysmography after a weight loss program in overweight and obese women
    C S Minderico
    A M Silva
    D A Fields
    T L Branco
    S S Martins
    P J Teixeira
    L B Sardinha
    [J]. European Journal of Clinical Nutrition, 2008, 62 : 444 - 450
  • [6] Body composition by air-displacement plethysmography by using predicted and measured thoracic gas volumes
    McCrory, MA
    Molé, PA
    Gomez, TD
    Dewey, KG
    Bernauer, EM
    [J]. JOURNAL OF APPLIED PHYSIOLOGY, 1998, 84 (04) : 1475 - 1479
  • [7] The effect of acute moderate-intensity exercise on the accuracy of air-displacement plethysmography in young adults
    R Otterstetter
    K E Johnson
    D L Kiger
    S E Agnor
    J Edwards
    J B Naylor
    S J Krone
    [J]. European Journal of Clinical Nutrition, 2013, 67 : 1092 - 1094
  • [8] The effect of acute moderate-intensity exercise on the accuracy of air-displacement plethysmography in young adults
    Otterstetter, R.
    Johnson, K. E.
    Kiger, D. L.
    Agnor, S. E.
    Edwards, J.
    Naylor, J. B.
    Krone, S. J.
    [J]. EUROPEAN JOURNAL OF CLINICAL NUTRITION, 2013, 67 (10) : 1092 - 1094
  • [9] Comparison Of Percent Body Fat From Ultrasonography And Air-displacement Plethysmography In Young
    Dixon, Curt B.
    Royer, Carrie
    Andreacci, Joseph L.
    Haile, Luke
    [J]. MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2013, 45 (05): : 443 - 443
  • [10] Effect of Arm and Leg Hair on Body Volume Measurement Using Air-displacement Plethysmography
    Coles, Michael G.
    Lyke, Juliette D.
    Greer, Felicia
    Gilbert, Jenelle N.
    [J]. MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2010, 42 (05): : 627 - 627