Side-by-side comparison of three sampling methods for aerosolized endotoxin in a wastewater treatment facility

被引:0
|
作者
Stephenson, DJ [1 ]
Lillquist, DR [1 ]
DeRosso, FD [1 ]
Greene, DD [1 ]
White, G [1 ]
机构
[1] Boise State Univ, Coll Hlth Sci, Dept Hlth Studies, Environm Hlth Program, Boise, ID 83725 USA
关键词
D O I
暂无
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Research studies have established the occurrence of adverse health effects in individuals exposed to organic dusts and water aerosols laden with endotoxin. To determine what exposure levels cause these health effects, it is necessary to quantify airborne endotoxin. Several scientific studies have demonstrated that the quantification of detectable endotoxin is affected by differences in sampling media, analytical method, and aerosol composition. The study reported here performed side-by-side endotoxin sampling using a liquid impinger, a glass fiber filter, and a polycarbonate filter in a wastewater treatment plant. Results show levels of detected endotoxin appear to be highest with the impinger. Coefficients of variation calculated for each sampling method show the glass fiber filter having the least variability when sampling was conducted at the highest endotoxin levels. Lastly, a Spearman rank order correlation test identified an apparent correlation between endotoxin levels obtained with the impinger and the glass fiber filter.
引用
收藏
页码:16 / 19
页数:4
相关论文
共 50 条
  • [1] A side-by-side comparison of three allergen sampling methods in settled house dust
    Sandel, Megan
    Murphy, Johnna S.
    Dixon, Sherry L.
    Adgate, John L.
    Chew, Ginger L.
    Dorevitch, Samuel
    Jacobs, David E.
    [J]. JOURNAL OF EXPOSURE SCIENCE AND ENVIRONMENTAL EPIDEMIOLOGY, 2014, 24 (06) : 650 - 656
  • [2] A side-by-side comparison of three allergen sampling methods in settled house dust
    Megan Sandel
    Johnna S Murphy
    Sherry L Dixon
    John L Adgate
    Ginger L Chew
    Samuel Dorevitch
    David E Jacobs
    [J]. Journal of Exposure Science & Environmental Epidemiology, 2014, 24 : 650 - 656
  • [3] A side-by-side comparison of sampling methods for indoor allergens.
    Mansour, M
    Lanphear, B
    Hornung, R
    Khoury, J
    Bernstein, D
    Menrath, B
    Decolongon, J
    [J]. JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY, 1999, 103 (01) : S22 - S22
  • [4] A side-by-side comparison of sampling methods for settled, indoor allergens
    Mansour, M
    Lanphear, BP
    Hornung, R
    Khoury, J
    Bernstein, DI
    Menrath, W
    Decolongon, J
    [J]. ENVIRONMENTAL RESEARCH, 2001, 87 (01) : 37 - 46
  • [5] Thermogalvanic cells: A side-by-side comparison of measurement methods
    Buckingham, Mark A.
    Aldous, Leigh
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2020, 872
  • [6] A SIDE-BY-SIDE COMPARISON OF DUST COLLECTION METHODS FOR SAMPLING LEAD-CONTAMINATED HOUSE-DUST
    LANPHEAR, BP
    EMOND, M
    JACOBS, DE
    WEITZMAN, M
    TANNER, M
    WINTER, NL
    YAKIR, B
    EBERLY, S
    [J]. ENVIRONMENTAL RESEARCH, 1995, 68 (02) : 114 - 123
  • [7] Side-by-Side Comparison of Methods for Environmental Monitoring for Hazardous Drug Contamination
    Hon, Chun-Yip
    [J]. CANADIAN JOURNAL OF HOSPITAL PHARMACY, 2023, 76 (02): : 87 - 93
  • [8] A side-by-side comparison of carbon dioxide resurfacing lasers for the treatment of rhytides
    Gross, EA
    Rogers, GS
    [J]. JOURNAL OF THE AMERICAN ACADEMY OF DERMATOLOGY, 1998, 39 (04) : 547 - 553
  • [9] Comparison of wake structures and force measurements behind three side-by-side cylinders
    Shams Ul Islam
    Hamid Rahman
    Zhou Chao Ying
    Suvash Chandra Saha
    [J]. Journal of the Brazilian Society of Mechanical Sciences and Engineering, 2016, 38 : 843 - 858
  • [10] Comparison of wake structures and force measurements behind three side-by-side cylinders
    Ul Islam, Shams
    Rahman, Hamid
    Ying, Zhou Chao
    Saha, Suvash Chandra
    [J]. JOURNAL OF THE BRAZILIAN SOCIETY OF MECHANICAL SCIENCES AND ENGINEERING, 2016, 38 (03) : 843 - 858