A side-by-side comparison of sampling methods for settled, indoor allergens

被引:12
|
作者
Mansour, M [1 ]
Lanphear, BP
Hornung, R
Khoury, J
Bernstein, DI
Menrath, W
Decolongon, J
机构
[1] Univ Cincinnati, Childrens Hosp, Ctr Med, CLASS, Cincinnati, OH 45229 USA
[2] Univ Cincinnati, Dept Pediat, Cincinnati, OH 45229 USA
[3] Univ Cincinnati, Inst Hlth Policy & Hlth Serv Res, Cincinnati, OH 45229 USA
[4] Univ Cincinnati, Dept Environm Hlth, Cincinnati, OH 45229 USA
[5] Univ Cincinnati, Dept Internal Med, Cincinnati, OH 45229 USA
关键词
dust; IgE; sampling; indoor allergens; asthma; children; environment; pediatrics;
D O I
10.1006/enrs.2001.4284
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Exposure to indoor allergens is associated with asthma, but there is no standardized sampling method for measuring allergens. We compared the association of measured allergen exposure and serum-specific IgE levels and the precision of three sampling methods (Cyclone, Mighty Mite, and Readivac II) to identify a standardized sampling method for indoor allergens. A random sample of 72 children, 5 to 17 years old, with doctor-diagnosed asthma who lived in the same residence greater than or equal to2 years were enrolled. Composite, side by side floor samples were obtained with all three methods. Dust allergen concentrations and serum-specific IgE levels were measured for Der f I, Fel d I, and Bla g I Mean allergen concentration did not differ significantly by sampling method. Cat allergen was significantly correlated with serum-specific IgE for Cyclone (P=0.003) and Mighty Mite (P=0.008), but only marginally for Readivac II (P=0.07). Dust mite allergen was significantly correlated with serum-specific IgE for Readivac II (P=0.02) and Cyclone (P=0.038), but not for Mighty Mite (P=0.12). Cockroach allergen was not correlated with serum-specific IgE for any sampling method. In multiple linear regression, cat allergen was associated with serum-specific IgE for Cyclone (P=0.007) and Mighty Mite (P=0.02), but not for Readivac II (P=0.06). In contrast, dust mite allergen was marginally associated with serum-specific IgE for Readivac II (P=0.07), but not for Mighty Mite (P=0.64) or Cyclone (P=0.27). The Cyclone and Mighty Mite were more precise than Readivac II for cat allergen, but there was no difference for dust mite allergen (P >0.05). No single method is superior for measurement of indoor allergens. In general, cat allergen collected with the Cyclone was a better predictor of serum-specific IgE levels to Fel d I, whereas dust mite allergen collected with the Readivac II was a better predictor of serum-specific IgE levels to Der f I, (C) 2001 Academic Press.
引用
收藏
页码:37 / 46
页数:10
相关论文
共 50 条
  • [1] A side-by-side comparison of sampling methods for indoor allergens.
    Mansour, M
    Lanphear, B
    Hornung, R
    Khoury, J
    Bernstein, D
    Menrath, B
    Decolongon, J
    [J]. JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY, 1999, 103 (01) : S22 - S22
  • [2] A side-by-side comparison of three allergen sampling methods in settled house dust
    Sandel, Megan
    Murphy, Johnna S.
    Dixon, Sherry L.
    Adgate, John L.
    Chew, Ginger L.
    Dorevitch, Samuel
    Jacobs, David E.
    [J]. JOURNAL OF EXPOSURE SCIENCE AND ENVIRONMENTAL EPIDEMIOLOGY, 2014, 24 (06) : 650 - 656
  • [3] A side-by-side comparison of three allergen sampling methods in settled house dust
    Megan Sandel
    Johnna S Murphy
    Sherry L Dixon
    John L Adgate
    Ginger L Chew
    Samuel Dorevitch
    David E Jacobs
    [J]. Journal of Exposure Science & Environmental Epidemiology, 2014, 24 : 650 - 656
  • [4] Side-by-side comparison of three sampling methods for aerosolized endotoxin in a wastewater treatment facility
    Stephenson, DJ
    Lillquist, DR
    DeRosso, FD
    Greene, DD
    White, G
    [J]. JOURNAL OF ENVIRONMENTAL HEALTH, 2004, 67 (04) : 16 - 19
  • [5] Thermogalvanic cells: A side-by-side comparison of measurement methods
    Buckingham, Mark A.
    Aldous, Leigh
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2020, 872
  • [6] A SIDE-BY-SIDE COMPARISON OF DUST COLLECTION METHODS FOR SAMPLING LEAD-CONTAMINATED HOUSE-DUST
    LANPHEAR, BP
    EMOND, M
    JACOBS, DE
    WEITZMAN, M
    TANNER, M
    WINTER, NL
    YAKIR, B
    EBERLY, S
    [J]. ENVIRONMENTAL RESEARCH, 1995, 68 (02) : 114 - 123
  • [7] Side-by-Side Comparison of Methods for Environmental Monitoring for Hazardous Drug Contamination
    Hon, Chun-Yip
    [J]. CANADIAN JOURNAL OF HOSPITAL PHARMACY, 2023, 76 (02): : 87 - 93
  • [8] SIDE-BY-SIDE
    MONTELEONI, M
    [J]. NATURE, 1995, 375 (6532) : 530 - 530
  • [9] Analysis of Ethanol in Beer Using Gas Chromatography: A Side-by-Side Comparison of Calibration Methods
    Hunter, Rebecca A.
    [J]. JOURNAL OF CHEMICAL EDUCATION, 2021, 98 (04) : 1404 - 1409
  • [10] Concordance of flicker comparison versus side-by-side comparison in glaucoma
    Cymbor, Michael
    Lear, Lindsey
    Mastrine, Matthew
    [J]. OPTOMETRY-JOURNAL OF THE AMERICAN OPTOMETRIC ASSOCIATION, 2009, 80 (08) : 437 - 441