摘要
Understanding allergen exposure and potential relationships with asthma requires allergen sampling methods, but methods have yet to be standardized. We compared allergen measurements from dust collected from 200 households with asthmatics and conducted a side-by-side vacuum sampling of settled dust in each home's kitchen, living room and subject's bedroom by three methods (EMM, HVS4 and AIHA). Each sample was analyzed for dust mite, cockroach, mouse, rat, cat and dog allergens. The number of samples with sufficient dust mass for allergen analysis was significantly higher for Eureka Mighty Mite (EMM) and high volume small surface sampler (HVS4) compared with American Industrial Hygiene Association (AIHA) in all rooms and surfaces tested (all P<0.05). The allergen concentration (weight of allergen divided by total weight of dust sampled) measured by the EMM and HVS4 methods was higher than that measured by the AIHA. Allergen loadings (weight of allergen divided by surface area sampled) were significantly higher for HVS4 than for AIHA and EMM. Cockroach and rat allergens were rarely detected via any method. The EMM method is most likely to collect sufficient dust from surfaces in the home and is relatively practical and easy. The AIHA and HVS4 methods suffer from insufficient dust collection and/or difficulty in use.
引用
收藏
页码:650 / 656
页数:7
相关论文
共 50 条
  • [1] A side-by-side comparison of three allergen sampling methods in settled house dust
    Megan Sandel
    Johnna S Murphy
    Sherry L Dixon
    John L Adgate
    Ginger L Chew
    Samuel Dorevitch
    David E Jacobs
    [J]. Journal of Exposure Science & Environmental Epidemiology, 2014, 24 : 650 - 656
  • [2] A side-by-side comparison of sampling methods for settled, indoor allergens
    Mansour, M
    Lanphear, BP
    Hornung, R
    Khoury, J
    Bernstein, DI
    Menrath, W
    Decolongon, J
    [J]. ENVIRONMENTAL RESEARCH, 2001, 87 (01) : 37 - 46
  • [3] A SIDE-BY-SIDE COMPARISON OF DUST COLLECTION METHODS FOR SAMPLING LEAD-CONTAMINATED HOUSE-DUST
    LANPHEAR, BP
    EMOND, M
    JACOBS, DE
    WEITZMAN, M
    TANNER, M
    WINTER, NL
    YAKIR, B
    EBERLY, S
    [J]. ENVIRONMENTAL RESEARCH, 1995, 68 (02) : 114 - 123
  • [4] Side-by-side comparison of three sampling methods for aerosolized endotoxin in a wastewater treatment facility
    Stephenson, DJ
    Lillquist, DR
    DeRosso, FD
    Greene, DD
    White, G
    [J]. JOURNAL OF ENVIRONMENTAL HEALTH, 2004, 67 (04) : 16 - 19
  • [5] A side-by-side comparison of sampling methods for indoor allergens.
    Mansour, M
    Lanphear, B
    Hornung, R
    Khoury, J
    Bernstein, D
    Menrath, B
    Decolongon, J
    [J]. JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY, 1999, 103 (01) : S22 - S22
  • [6] Thermogalvanic cells: A side-by-side comparison of measurement methods
    Buckingham, Mark A.
    Aldous, Leigh
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2020, 872
  • [7] Side-by-Side Comparison of Methods for Environmental Monitoring for Hazardous Drug Contamination
    Hon, Chun-Yip
    [J]. CANADIAN JOURNAL OF HOSPITAL PHARMACY, 2023, 76 (02): : 87 - 93
  • [8] Comparison of wake structures and force measurements behind three side-by-side cylinders
    Shams Ul Islam
    Hamid Rahman
    Zhou Chao Ying
    Suvash Chandra Saha
    [J]. Journal of the Brazilian Society of Mechanical Sciences and Engineering, 2016, 38 : 843 - 858
  • [9] Comparison of wake structures and force measurements behind three side-by-side cylinders
    Ul Islam, Shams
    Rahman, Hamid
    Ying, Zhou Chao
    Saha, Suvash Chandra
    [J]. JOURNAL OF THE BRAZILIAN SOCIETY OF MECHANICAL SCIENCES AND ENGINEERING, 2016, 38 (03) : 843 - 858
  • [10] Comparison of three side-by-side real-time dust monitors in a duct using average and peak display dust levels as parameters of performance evaluation
    Belle, B. K.
    [J]. 11th U.S./ North American Mine Ventilation Symposium 2006, 2006, : 179 - 187