Effect of various dental restorations on dose distribution of 6 MV photon beam

被引:3
|
作者
Azizi, Mona [1 ]
Mowlavi, Ali Asghar [1 ,3 ]
Ghorbani, Mahdi [2 ]
Davenport, David [4 ]
机构
[1] Hakim Sabzevari Univ, Sch Sci, Dept Phys, Tohid Sahar Campus, Sabzevar, Iran
[2] Mashhad Univ Med Sci, Med Phys Res Ctr, Mashhad, Iran
[3] Abdus Salaam Int Ctr Theoret Phys, Trieste, Italy
[4] Comprehens Canc Ctr Nevada, Las Vegas, NV USA
关键词
Dental restoration; dose distribution; Monte Carlo simulation; radiotherapy; MONTE-CARLO; RADIATION-THERAPY; IRRADIATION; PROSTHESES; ELECTRON; IMPLANTS; METAL;
D O I
10.4103/0973-1482.187245
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Aim: The purpose of this study is to evaluate the effect of various dental restoration materials on dose distribution in radiotherapy of head and neck cancer with 6 MV photon beam of a medical linac. Setting and Design: The dental restorations include tooth, tooth with amalgam, tooth with Ni-Cr alloy, and tooth with Ceramco. Dose perturbation due to the dental restorations on 6 MV beam of Siemens Primus linac was calculated by MCNPX Monte Carlo code. These dental materials were separately simulated in a cubic water phantom. Materials and Methods: Photon percentage dose change in the presence of tooth, tooth with amalgam, tooth with Ni-Cr alloy, and tooth with Ceramco was calculated at various depths on the central axis of the beam relative to the dose in water. In another evaluation, the absolute dose (cGy) for water, tooth, tooth with amalgam, tooth with Ni-Cr alloy, and tooth with Ceramco was obtained by calculating 100 cGy dose at 0.75 cm depth in the water phantom. Results: Based on the calculations performed, maximum percentage dose change due to backscattering was 11%, 8%, 6%, and 4% for amalgam, Ni-Cr alloy, Ceramco and tooth at depth of 0.75 cm, respectively. The maximum dose perturbation by amalgam is due to its higher mass density and atomic number. Conclusion: Ignoring the effect of dental restoration compositions on dose distribution causes discrepancy in clinical treatment planning system calculations.
引用
收藏
页码:538 / 543
页数:6
相关论文
共 50 条
  • [41] Impact of the dose quantity used in MV photon optimization on dose distribution, robustness, and complexity
    Jurado-Bruggeman, Diego
    Munoz-Montplet, Carles
    Hernandez, Victor
    Saez, Jordi
    Fuentes-Raspall, Rafael
    MEDICAL PHYSICS, 2022, 49 (01) : 648 - 665
  • [42] Effect of tissue composition on dose distribution in brachytherapy with various photon emitting sources
    Ghorbani, Mahdi
    Salahshour, Fateme
    Haghparast, Abbas
    Moghaddas, Toktam Ahmadi
    Knaup, Courtney
    JOURNAL OF CONTEMPORARY BRACHYTHERAPY, 2014, 6 (01) : 54 - 67
  • [43] Effect of Surface Dose and Depth of Maximum Dose with Physical Wedge Filters for 6MV Flattened and 7MV Unflattened Photon Beams
    Ashokkumar, S.
    Sinha, S. N.
    Yadav, Girigesh
    Raman, Kothanda
    Thiyagarajan, Rajesh
    Nambiraj, N. Arunai
    MEDICAL PHYSICS, 2012, 39 (06) : 3737 - 3738
  • [44] Dosimetric properties of a beam quality-matched 6 MV unflattened photon beam
    Huang, Yunfei
    Siochi, R. Alfredo
    Bayouth, John E.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2012, 13 (04): : 71 - 81
  • [45] Verification of asymmetric wedge dose calculations for 6 MV beam
    Vatyam, S
    Kannan, V
    Anand, V
    Hinduja, PD
    MEDICAL PHYSICS, 2003, 30 (06) : 1482 - 1482
  • [46] NEUTRON DOSE DELIVERED WHEN USING 18 MV UNFLATTENED PHOTON BEAM
    Vondracek, V.
    Kralik, M.
    Turek, K.
    Navratil, M.
    Kubes, J.
    RADIOTHERAPY AND ONCOLOGY, 2010, 96 : S476 - S476
  • [47] Evaluation of the dosimetric characteristics of 6 MV flattened and unflattened photon beam
    Mohammed, Maged
    Chakir, E.
    Boukhal, H.
    Mroan, S.
    El Bardouni, T.
    JOURNAL OF KING SAUD UNIVERSITY SCIENCE, 2017, 29 (03) : 371 - 379
  • [48] Source model tuning for a 6 MV photon beam used in radiotherapy
    Hirschi, Lukas A.
    Siebers, Jeffrey V.
    Fix, Michael K.
    FIRST EUROPEAN WORKSHOP ON MONTE CARLO TREATMENT PLANNING, 2007, 74
  • [49] Characterization of GaN dosimetry for 6 MV photon beam in clinical conditions
    Chaikh, A.
    Balosso, J.
    Giraud, J. -Y.
    Wang, R.
    Pittet, P.
    Lu, G. -N.
    RADIATION MEASUREMENTS, 2014, 71 : 392 - 395
  • [50] Investigation of the RBE of radiation in the penumbra of a 6mv photon beam
    Syme, A.
    Kirkby, C.
    Mirzayans, R.
    MacKenzie, M.
    Field, C.
    Fallone, G.
    RADIOTHERAPY AND ONCOLOGY, 2007, 84 : S78 - S78