Effect of various dental restorations on dose distribution of 6 MV photon beam

被引:3
|
作者
Azizi, Mona [1 ]
Mowlavi, Ali Asghar [1 ,3 ]
Ghorbani, Mahdi [2 ]
Davenport, David [4 ]
机构
[1] Hakim Sabzevari Univ, Sch Sci, Dept Phys, Tohid Sahar Campus, Sabzevar, Iran
[2] Mashhad Univ Med Sci, Med Phys Res Ctr, Mashhad, Iran
[3] Abdus Salaam Int Ctr Theoret Phys, Trieste, Italy
[4] Comprehens Canc Ctr Nevada, Las Vegas, NV USA
关键词
Dental restoration; dose distribution; Monte Carlo simulation; radiotherapy; MONTE-CARLO; RADIATION-THERAPY; IRRADIATION; PROSTHESES; ELECTRON; IMPLANTS; METAL;
D O I
10.4103/0973-1482.187245
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Aim: The purpose of this study is to evaluate the effect of various dental restoration materials on dose distribution in radiotherapy of head and neck cancer with 6 MV photon beam of a medical linac. Setting and Design: The dental restorations include tooth, tooth with amalgam, tooth with Ni-Cr alloy, and tooth with Ceramco. Dose perturbation due to the dental restorations on 6 MV beam of Siemens Primus linac was calculated by MCNPX Monte Carlo code. These dental materials were separately simulated in a cubic water phantom. Materials and Methods: Photon percentage dose change in the presence of tooth, tooth with amalgam, tooth with Ni-Cr alloy, and tooth with Ceramco was calculated at various depths on the central axis of the beam relative to the dose in water. In another evaluation, the absolute dose (cGy) for water, tooth, tooth with amalgam, tooth with Ni-Cr alloy, and tooth with Ceramco was obtained by calculating 100 cGy dose at 0.75 cm depth in the water phantom. Results: Based on the calculations performed, maximum percentage dose change due to backscattering was 11%, 8%, 6%, and 4% for amalgam, Ni-Cr alloy, Ceramco and tooth at depth of 0.75 cm, respectively. The maximum dose perturbation by amalgam is due to its higher mass density and atomic number. Conclusion: Ignoring the effect of dental restoration compositions on dose distribution causes discrepancy in clinical treatment planning system calculations.
引用
收藏
页码:538 / 543
页数:6
相关论文
共 50 条
  • [21] Surface dose measurements in chest wall postmastectomy radiotherapy to achieve optimal dose delivery with 6 MV photon beam
    Lobo, Dilson
    Banerjee, Sourjya
    Srinivas, Challapalli
    Athiyamaan, M. S.
    Reddy, Shreyas
    Sunny, Johan
    Ravichandran, Ramamoorthy
    Kotian, Himani
    Prakash Saxena, P. U.
    JOURNAL OF MEDICAL PHYSICS, 2021, 46 (04) : 324 - 333
  • [22] Impact of Air Gap On PDDs of 6 MV Photon Beam for Various Field Sizes in Inhomogeneous Phantoms
    Oyewale, S.
    Pokharel
    Singh, H.
    Islam, M.
    Rana, S.
    MEDICAL PHYSICS, 2015, 42 (06) : 3438 - 3438
  • [23] Dosimetric effect of jaws for small MLC fields in 6 and 15 MV photon beam
    Chow, J
    Seguin, M
    Alexander, A
    MEDICAL PHYSICS, 2005, 32 (06) : 1981 - 1982
  • [24] Dosimetry of a 6 MV flattening filter-free small photon beam using various detectors
    Dwivedi, Shekhar
    Kansal, Sandeep
    Dangwal, Vinod Kumar
    Bharati, Avinav
    Shukla, Jooli
    BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2021, 7 (04):
  • [25] Influence of RF Coil Materials On Surface and Buildup Dose From a 6MV Photon Beam
    Ghila, A.
    Fallone, B.
    Rathee, S.
    MEDICAL PHYSICS, 2015, 42 (06) : 3321 - 3321
  • [26] The dosimetric characterization of the performance of the one dose MOSFET dosimeter in the buildup region of a 6 MV photon beam
    Fallon, K
    Bednarz, G
    Galvin, J
    MEDICAL PHYSICS, 2005, 32 (06) : 2008 - 2009
  • [27] Therapeutic dose simulation of a 6 MV Varian Linac photon beam using GEANT4
    Salama, E.
    Ali, A. S.
    Khaled, N. E.
    Radi, A.
    JOURNAL OF INSTRUMENTATION, 2015, 10
  • [28] DOSE-RATE DEPENDENCE OF A PTW DIAMOND DETECTOR IN THE DOSIMETRY OF A 6 MV PHOTON-BEAM
    HOBAN, PW
    HEYDARIAN, M
    BECKHAM, WA
    BEDDOE, AH
    PHYSICS IN MEDICINE AND BIOLOGY, 1994, 39 (08): : 1219 - 1229
  • [29] Effect of density on the 10 MV photon beam penumbra
    Hoban, P.W.
    Keal, P.J.
    Round, W.H.
    Australasian Physical and Engineering Sciences in Medicine, 1992, 15 (03): : 113 - 123
  • [30] Validation of peregrine dose computations for a 6 MV beam
    Ezzell, G
    Chungbin, S
    MEDICAL PHYSICS, 2002, 29 (06) : 1262 - 1262