Coupling the use of anti-scatter grid with analytical scatter estimation in cone beam CT

被引:2
|
作者
Rinkel, J. [1 ]
Gerfault, L. [1 ]
Esteve, F. [2 ]
Dinten, J. -M. [1 ]
机构
[1] CEA LETI MINATEC, Div Micro Technol Biol & Hlthcare, F-38054 Grenoble, France
[2] European Synchrotron Radiat Facil, INSERM, U647 RSRM, F-38043 Grenoble, France
关键词
CT; RECONS; SCAT;
D O I
10.1117/12.706486
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Cone-Beam Computed Tomography (CBCT) enables three-dimensional imaging with isotropic resolution. X-ray scatter estimation is a big challenge for quantitative CBCT imaging: even in the presence of anti-scatter grid, the scatter level is significantly higher on cone beam systems compared to collimated fan beam systems. The effects of this scattered radiation include cupping artifacts, streaks, and quantification inaccuracies. In this paper, a scatter management process for tomographic projections, without supplementary on-line acquisition, is presented. The scattered radiation is corrected using a method based on scatter calibration through off-line acquisitions. This is combined with on-line analytical transformation based on physical equations, to perform an estimation adapted to the object observed. This approach has been previously applied to a system without anti-scatter grid. The focus of this paper is to show how to combine this approach with an anti-scatter grid. First, the interest of the grid is evaluated in terms of noise to signal ratio and scatter rejection. Then, the method of scatter correction is evaluated by testing it on an anthropomorphic phantom of thorax. The reconstructed volume of the phantom is compared to that obtained with a strongly collimated conventional multi-slice CT scanner. The new method provides results that closely agree with the conventional CT scanner, eliminating cupping artifacts and significantly improving quantification.
引用
收藏
页数:10
相关论文
共 50 条
  • [41] Coupling an analytical description of anti-scatter grids with simulation software of radiographic systems using Monte Carlo code
    Rinkel, J
    Tabary, J
    Estève, F
    Dinten, JM
    Medical Imaging 2005: Physics of Medical Imaging, Pts 1 and 2, 2005, 5745 : 835 - 846
  • [42] Effect of the anti-scatter grid and target/filters in full-field digital mammography
    Chakraborty, DP
    MEDICAL IMAGING 1999: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 1999, 3659 : 878 - 885
  • [43] Parameterization of Scatter Dependent Artifacts in Cone-Beam CT
    Mail, N.
    Moseley, D.
    Jaffray, D.
    MEDICAL PHYSICS, 2010, 37 (06)
  • [44] Effect of scatter radiation on image noise in cone beam CT
    Endo, M
    Tsunoo, T
    Nakamori, N
    MEDICAL IMAGING 2000: PHYSICS OF MEDICAL IMAGING, 2000, 3977 : 514 - 521
  • [45] Scatter Correction for Cone-Beam CT in Radiation Therapy
    Zhu, L.
    Xing, L.
    MEDICAL PHYSICS, 2008, 35 (06)
  • [46] A virtual anti-scatter grid for multi-energy photon counting detector systems
    Purisha, Zenith
    Winkler, Alexander
    Emzir, Muhammad
    Hostettler, Roland
    Luukka, Panja
    Sarkka, Simo
    PHYSICA SCRIPTA, 2024, 99 (10)
  • [47] Optimized anti-scatter grids for flat panel detectors
    Lendl, Markus
    Medical Imaging 2007: Physics of Medical Imaging, Pts 1-3, 2007, 6510 : U1236 - U1246
  • [48] Feasibility of Deep-Learning Based Synthetic Anti-Scatter Grid for Chest Radiographs
    Hamdan, S.
    Hoerner, M. R.
    Grizzard, K. T.
    Benyakoub, A.
    Mustafa, A. A.
    MEDICAL PHYSICS, 2024, 51 (10) : 7761 - 7761
  • [49] Compensators for management of dose and scatter in cone-beam CT
    Graham, S.
    Moseley, D.
    Siewerdsen, J.
    Jaffray, D.
    MEDICAL PHYSICS, 2006, 33 (06) : 1998 - 1999
  • [50] A Hybrid Scatter Correction Method for Cone-Beam CT
    Zhang, Feng
    Yan, Bin
    Li, Jianxin
    Li, Lei
    Jia, Pengxiang
    Hu, Guoen
    2010 3RD INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING AND INFORMATICS (BMEI 2010), VOLS 1-7, 2010, : 23 - 27