Coupling the use of anti-scatter grid with analytical scatter estimation in cone beam CT

被引:2
|
作者
Rinkel, J. [1 ]
Gerfault, L. [1 ]
Esteve, F. [2 ]
Dinten, J. -M. [1 ]
机构
[1] CEA LETI MINATEC, Div Micro Technol Biol & Hlthcare, F-38054 Grenoble, France
[2] European Synchrotron Radiat Facil, INSERM, U647 RSRM, F-38043 Grenoble, France
关键词
CT; RECONS; SCAT;
D O I
10.1117/12.706486
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Cone-Beam Computed Tomography (CBCT) enables three-dimensional imaging with isotropic resolution. X-ray scatter estimation is a big challenge for quantitative CBCT imaging: even in the presence of anti-scatter grid, the scatter level is significantly higher on cone beam systems compared to collimated fan beam systems. The effects of this scattered radiation include cupping artifacts, streaks, and quantification inaccuracies. In this paper, a scatter management process for tomographic projections, without supplementary on-line acquisition, is presented. The scattered radiation is corrected using a method based on scatter calibration through off-line acquisitions. This is combined with on-line analytical transformation based on physical equations, to perform an estimation adapted to the object observed. This approach has been previously applied to a system without anti-scatter grid. The focus of this paper is to show how to combine this approach with an anti-scatter grid. First, the interest of the grid is evaluated in terms of noise to signal ratio and scatter rejection. Then, the method of scatter correction is evaluated by testing it on an anthropomorphic phantom of thorax. The reconstructed volume of the phantom is compared to that obtained with a strongly collimated conventional multi-slice CT scanner. The new method provides results that closely agree with the conventional CT scanner, eliminating cupping artifacts and significantly improving quantification.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] Characterization of scatter radiation in cone beam CT mammography
    Liu, B
    Glick, SJ
    Groiselle, C
    MEDICAL IMAGING 2005: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 2005, 5745 : 818 - 827
  • [32] A PRACTICAL METHOD FOR SCATTER CORRECTION IN CONE BEAM CT
    Ploeger, L.
    Sonke, J. J.
    van Herk, M.
    RADIOTHERAPY AND ONCOLOGY, 2009, 92 : S129 - S129
  • [33] Can Anti-Scatter Grids Improve Image Quality in Breast CT
    Glick, S. J.
    Didier, C. S.
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING, VOL 25, PT 2 - DIAGNOSTIC IMAGING, 2009, 25 : 868 - 870
  • [34] Design, fabrication and testing of a large anti-scatter grid for Megavolt γ-ray imaging
    Watson, S. A.
    Appleby, M.
    Klinger, J.
    Balzer, S.
    Lebeda, C.
    Bowman, D.
    Montoya, J.
    Bultman, D.
    Vecere, C.
    Gossein, C.
    2005 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2005, : 717 - 721
  • [35] Digital selenium radiography: anti-scatter grid for chest radiography in a clinical study
    Bernhardt, TM
    Rapp-Bernhardt, U
    Hausmann, T
    Reichel, G
    Krause, UW
    Doehring, W
    BRITISH JOURNAL OF RADIOLOGY, 2000, 73 (873): : 963 - 968
  • [36] Contrast Enhanced Dual-Energy Mammography Without Anti-Scatter Grid
    Biniazan, R.
    Fieselmann, A.
    Hoernig, M.
    Maier, A.
    Mertelmeier, T.
    Nanke, R.
    Ritschl, L.
    MEDICAL PHYSICS, 2017, 44 (06) : 3102 - 3102
  • [37] A BAYESIAN APPROACH FOR ANTI-SCATTER GRID EXTRACTION IN X-RAY IMAGING
    Cotte, Florian
    Desvignes, Michel
    Ayasso, Hacheme
    Vignolle, Jean-Michel
    2018 25TH IEEE INTERNATIONAL CONFERENCE ON IMAGE PROCESSING (ICIP), 2018, : 1183 - 1187
  • [38] Selective Laser Melting Process and Performance of Pure Tungsten Anti-Scatter Grid
    Wang, Di
    Hu, Weinan
    Yang, Yongqiang
    Feng, Yonwei
    Zhang, Yingjie
    Yi, Hao
    Xiyou Jinshu/Chinese Journal of Rare Metals, 2023, 47 (05): : 757 - 768
  • [39] Scatter estimation and removal of anti-scatter grid-line artifacts from anthropomorphic head phantom images taken with a high resolution image detector
    Rana, R.
    Jain, A.
    Shankar, A.
    Bednarek, D. R.
    Rudin, S.
    MEDICAL IMAGING 2016: PHYSICS OF MEDICAL IMAGING, 2016, 9783
  • [40] Robust primary modulation-based scatter estimation for cone-beam CT
    Ritschl, Ludwig
    Fahrig, Rebecca
    Knaup, Michael
    Maier, Joscha
    Kachelriess, Marc
    MEDICAL PHYSICS, 2015, 42 (01) : 469 - 478