Performance assessment of low-energy buildings in central Argentina

被引:25
|
作者
Filippin, C.
Beascochea, A.
机构
[1] Consejo Nacl Invest Cient & Tecn, RA-6300 Santa Rosa, La Pampa, Argentina
[2] Univ Nacl La Pampa, RA-6300 Santa Rosa, La Pampa, Argentina
关键词
energy and thermal performance; low-energy buildings; fossil energy;
D O I
10.1016/j.enbuild.2006.08.011
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper summarizes the results obtained from the energy and thermal performance assessment of residential and non-residential low-energy buildings that were designed to minimize fossil energy use. They are located in the province of La Pampa, central Argentina, in a temperate continental climate that shows extreme hot and cold records during the summer and winter seasons, respectively. The common applied technologies for saving energy were passive solar heating, natural ventilation for cooling and daylighting. The glazing area in the principal functional spaces facing to the North oscillates between 11 and 17% of the building useful areas. All the studied buildings are massive, with the exception of an auditorium that was designed with a lightweight insulated technology. The mean thermal transmittance of the envelope is 0.45 W/ (m(2) K). Double glazing and hermetic carpentry were used to reduce thermal losses (U-value = 2.8 W/(m(2) K)). The volumetric heat loss coefficient (G-value) oscillates between 0.90 and 1.00 W/(m(3) K). During the design and thermal simulation convective-radiative heat transfer coefficients were estimated through a dimensional equation (h = 5.7 + 3.8 ws, wind speed). On internal surfaces, convective-radiative heat transfer coefficients of 8 and 6 W/(m(2) degrees C) (for surfaces with and without solar gain, respectively) were applied. The monitoring process provided information on the energy and thermal behaviour under use and non-use conditions. The measured value of energy consumption was similar to the expected value that was used during the pre-design stage. Building technologies work well during the winter season, allowing 50-80% of energy savings. However, overheating is still an unresolved problem during the summer. Interviews with occupants revealed that they need both, information about functional details, and good-practice guidance to manage thermal issues of the building. In most cases, the annual consumption of energy was lower than those established by the Low Energy Housing German Standards and the Minirgie Switzerland Certificate. Despite their relative cost increase during the last years, the use of insulation technology and the application of passive solar devices involved an extra cost of only 3% in our works. Provided the expected depletion of natural gas production in the coming decade, the importance of applying energy-efficiency guidelines will increase very soon in Argentina in order to match the requirements of a new national energy matrix. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:546 / 557
页数:12
相关论文
共 50 条
  • [41] Integrated Design - A paradigm for the design of low-energy office buildings
    Jorgensen, M.
    Nielsen, M. W.
    Stromann-Andersen, J. B.
    ASHRAE: TRANSACTIONS 2011, VOL 117, PT 1, 2011, 117 : 230 - 239
  • [42] Low-energy environmental improvement for glass curtain wall buildings
    Cheng, M.
    Zheng, X. Z.
    Cao, W.
    APPLIED MECHANICS AND CIVIL ENGINEERING VI, 2017, : 65 - 72
  • [43] Statistical simulation of user behaviour in low-energy office buildings
    Pfafferott, J.
    Herkel, S.
    SOLAR ENERGY, 2007, 81 (05) : 676 - 682
  • [44] CENTRE OF LOW-ENERGY BUILDINGS IN PISEK - A CASE STUDY FOR NZEB
    Matuska, Tomas
    Lain, Milos
    Zmrhal, Vladimir
    SUSTAINABLE BUILDING AND REFURBISHMENT FOR NEXT GENERATIONS, 2013, : 111 - 114
  • [45] A Parametric Study for Integrated Design Optimization of Low-Energy Buildings
    Kilkis, Siir
    Kilkis, Birol
    ASHRAE: TRANSACTIONS 2011, VOL 117, PT 1, 2011, 117 : 442 - 449
  • [46] A comparative case study of passive and low-energy residential buildings
    Mahdavi, A.
    Doppelbauer, E. M.
    Proeglhoef, C.
    RESEARCH ON BUILDING PHYSICS, 2010, : 441 - 446
  • [47] Energy, comfort, and environmental assessment of passive techniques integrated into low-energy residential buildings in semi-arid climate
    Mousavi, Seyedehniloufar
    Gijon-Rivera, M.
    Rivera-Solorio, C., I
    Godoy Rangel, Caribay
    ENERGY AND BUILDINGS, 2022, 263
  • [48] EnergiBUS4home-Sustainable energy resourcing in low-energy buildings
    Roedder, Maximilian
    Frank, Lena
    Kirschner, Daniel
    Neef, Matthias
    Adam, Mario
    ENERGY, 2018, 159 : 638 - 647
  • [49] FROM LOW-ENERGY TO NET ZERO-ENERGY BUILDINGS: STATUS AND PERSPECTIVES
    Voss, Karsten
    Musall, Eike
    Lichtmess, Markus
    JOURNAL OF GREEN BUILDING, 2011, 6 (01): : 46 - 57
  • [50] Energy use in the life cycle of conventional and low-energy buildings: A review article
    Sartori, I.
    Hestnes, A. G.
    ENERGY AND BUILDINGS, 2007, 39 (03) : 249 - 257