Performance assessment of low-energy buildings in central Argentina

被引:25
|
作者
Filippin, C.
Beascochea, A.
机构
[1] Consejo Nacl Invest Cient & Tecn, RA-6300 Santa Rosa, La Pampa, Argentina
[2] Univ Nacl La Pampa, RA-6300 Santa Rosa, La Pampa, Argentina
关键词
energy and thermal performance; low-energy buildings; fossil energy;
D O I
10.1016/j.enbuild.2006.08.011
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper summarizes the results obtained from the energy and thermal performance assessment of residential and non-residential low-energy buildings that were designed to minimize fossil energy use. They are located in the province of La Pampa, central Argentina, in a temperate continental climate that shows extreme hot and cold records during the summer and winter seasons, respectively. The common applied technologies for saving energy were passive solar heating, natural ventilation for cooling and daylighting. The glazing area in the principal functional spaces facing to the North oscillates between 11 and 17% of the building useful areas. All the studied buildings are massive, with the exception of an auditorium that was designed with a lightweight insulated technology. The mean thermal transmittance of the envelope is 0.45 W/ (m(2) K). Double glazing and hermetic carpentry were used to reduce thermal losses (U-value = 2.8 W/(m(2) K)). The volumetric heat loss coefficient (G-value) oscillates between 0.90 and 1.00 W/(m(3) K). During the design and thermal simulation convective-radiative heat transfer coefficients were estimated through a dimensional equation (h = 5.7 + 3.8 ws, wind speed). On internal surfaces, convective-radiative heat transfer coefficients of 8 and 6 W/(m(2) degrees C) (for surfaces with and without solar gain, respectively) were applied. The monitoring process provided information on the energy and thermal behaviour under use and non-use conditions. The measured value of energy consumption was similar to the expected value that was used during the pre-design stage. Building technologies work well during the winter season, allowing 50-80% of energy savings. However, overheating is still an unresolved problem during the summer. Interviews with occupants revealed that they need both, information about functional details, and good-practice guidance to manage thermal issues of the building. In most cases, the annual consumption of energy was lower than those established by the Low Energy Housing German Standards and the Minirgie Switzerland Certificate. Despite their relative cost increase during the last years, the use of insulation technology and the application of passive solar devices involved an extra cost of only 3% in our works. Provided the expected depletion of natural gas production in the coming decade, the importance of applying energy-efficiency guidelines will increase very soon in Argentina in order to match the requirements of a new national energy matrix. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:546 / 557
页数:12
相关论文
共 50 条
  • [21] Heating system energy flexibility of low-energy residential buildings
    Foteinaki, Kyriaki
    Li, Rongling
    Heller, Alfred
    Rode, Carsten
    ENERGY AND BUILDINGS, 2018, 180 : 95 - 108
  • [22] Low-energy buildings in combination with grid decarbonization, life cycle assessment of passive house buildings in Northern Ireland
    Norouzi, Masoud
    Colclough, Shane
    Jimenez, Laureano
    Gavalda, Jordi
    Boer, Dieter
    ENERGY AND BUILDINGS, 2022, 261
  • [23] Low-energy residential buildings in New Borg El Arab: Simulation and survey based energy assessment
    Reda, Francesco
    Tuominen, Pekka
    Hedman, Asa
    Ibrahim, Mona Gamal Eldin
    ENERGY AND BUILDINGS, 2015, 93 : 65 - 82
  • [24] Proposed Metrics For IAQ in Low-Energy Residential Buildings
    Abadie, Marc
    Wargocki, Pawel
    Rode, Carsten
    Zhang, Jensen
    ASHRAE JOURNAL, 2019, 61 (01) : 62 - 65
  • [25] Developing standards for low-energy buildings in the Gulf states
    Radhi, Hassan
    Sharples, Steve
    Architectural Science Review, 2008, 51 (04) : 369 - 381
  • [26] Proposed metrics for IAQ in low-energy residential buildings
    Laboratoire des Sciences de l’Ingénieur pour l’Environnement , Department of Civil Engineering, University of La Rochelle, La Rochelle, France
    不详
    不详
    ASHRAE J, 2019, 1 (62-65):
  • [27] ADVANCED GLAZING TECHNOLOGY FOR LOW-ENERGY BUILDINGS IN THE UK
    ROBINSON, PD
    HUTCHINS, MG
    RENEWABLE ENERGY, 1994, 5 (1-4) : 298 - 309
  • [28] A Tool for Optimal Refurbishment Design of Low-Energy Buildings
    Salerno, I
    Anjos, M. F.
    McKinnon, K.
    Mazzucchelli, E. S.
    CARBON-NEUTRAL CITIES - ENERGY EFFICIENCY AND RENEWABLES IN THE DIGITAL ERA (CISBAT 2021), 2021, 2042
  • [29] A review on chemisorption heat storage in low-energy buildings
    Kuznik, Frederic
    Johannes, Kevyn
    2013 ISES SOLAR WORLD CONGRESS, 2014, 57 : 2333 - 2341
  • [30] Envelope design for low-energy buildings in the tropics: A review
    Gupta, V.
    Deb, C.
    RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2023, 186