Performance assessment of low-energy buildings in central Argentina

被引:25
|
作者
Filippin, C.
Beascochea, A.
机构
[1] Consejo Nacl Invest Cient & Tecn, RA-6300 Santa Rosa, La Pampa, Argentina
[2] Univ Nacl La Pampa, RA-6300 Santa Rosa, La Pampa, Argentina
关键词
energy and thermal performance; low-energy buildings; fossil energy;
D O I
10.1016/j.enbuild.2006.08.011
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper summarizes the results obtained from the energy and thermal performance assessment of residential and non-residential low-energy buildings that were designed to minimize fossil energy use. They are located in the province of La Pampa, central Argentina, in a temperate continental climate that shows extreme hot and cold records during the summer and winter seasons, respectively. The common applied technologies for saving energy were passive solar heating, natural ventilation for cooling and daylighting. The glazing area in the principal functional spaces facing to the North oscillates between 11 and 17% of the building useful areas. All the studied buildings are massive, with the exception of an auditorium that was designed with a lightweight insulated technology. The mean thermal transmittance of the envelope is 0.45 W/ (m(2) K). Double glazing and hermetic carpentry were used to reduce thermal losses (U-value = 2.8 W/(m(2) K)). The volumetric heat loss coefficient (G-value) oscillates between 0.90 and 1.00 W/(m(3) K). During the design and thermal simulation convective-radiative heat transfer coefficients were estimated through a dimensional equation (h = 5.7 + 3.8 ws, wind speed). On internal surfaces, convective-radiative heat transfer coefficients of 8 and 6 W/(m(2) degrees C) (for surfaces with and without solar gain, respectively) were applied. The monitoring process provided information on the energy and thermal behaviour under use and non-use conditions. The measured value of energy consumption was similar to the expected value that was used during the pre-design stage. Building technologies work well during the winter season, allowing 50-80% of energy savings. However, overheating is still an unresolved problem during the summer. Interviews with occupants revealed that they need both, information about functional details, and good-practice guidance to manage thermal issues of the building. In most cases, the annual consumption of energy was lower than those established by the Low Energy Housing German Standards and the Minirgie Switzerland Certificate. Despite their relative cost increase during the last years, the use of insulation technology and the application of passive solar devices involved an extra cost of only 3% in our works. Provided the expected depletion of natural gas production in the coming decade, the importance of applying energy-efficiency guidelines will increase very soon in Argentina in order to match the requirements of a new national energy matrix. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:546 / 557
页数:12
相关论文
共 50 条
  • [31] A review on switchable building envelopes for low-energy buildings
    Zhang, Guangpeng
    Wu, Huijun
    Liu, Jia
    Liu, Yanchen
    Ding, Yujie
    Huang, Huakun
    RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2024, 202
  • [32] Stochastic assessment of the energy performance of buildings
    Chari, Andreas
    Xanthos, Savvas
    Christodoulou, Symeon E.
    ENERGY EFFICIENCY, 2017, 10 (06) : 1573 - 1591
  • [33] Stochastic assessment of the energy performance of buildings
    Andreas Chari
    Savvas Xanthos
    Symeon E. Christodoulou
    Energy Efficiency, 2017, 10 : 1573 - 1591
  • [34] Energy-saving Technical Measures of German Low-energy Buildings
    Liu Lia
    Xu Lei
    SUSTAINABLE DEVELOPMENT OF URBAN AND RURAL AREAS, 2014, 507 : 511 - 514
  • [35] Energy and comfort performance assessment of monitored low energy buildings connected to low-temperature district heating
    Himpe, Eline
    Janssens, Arnold
    Rebollar, Julio Efrain Vaillant
    6TH INTERNATIONAL BUILDING PHYSICS CONFERENCE (IBPC 2015), 2015, 78 : 3465 - 3470
  • [36] Low-energy cooling and ventilation refurbishments for buildings in a Mediterranean climate
    Spentzou, E.
    Cook, M. J.
    Emmitt, S.
    ARCHITECTURAL ENGINEERING AND DESIGN MANAGEMENT, 2022, 18 (04) : 473 - 494
  • [37] Extremely Low-Energy Design for Army Buildings: Dining Facility
    Deru, Michael
    Langner, Rois
    Zhivov, Alexander
    Liesen, Richard
    Herron, Dale
    Smith, Vernon
    ASHRAE TRANSACTIONS 2012, VOL 118, PT 1, 2012, 118 : 790 - 815
  • [38] OPERATING EXPERIENCE OF LOW-ENERGY BUILDINGS IN THE UNITED-KINGDOM
    JOHN, RW
    WILLIS, STP
    SALVIDGE, AC
    ENERGY AND BUILDINGS, 1990, 14 (03) : 231 - 235
  • [39] Composite Materials Based on Hemp and Flax for Low-Energy Buildings
    Brzyski, Przemyslaw
    Barnat-Hunek, Danuta
    Suchorab, Zbigniew
    Lagod, Grzegorz
    MATERIALS, 2017, 10 (05): : 510
  • [40] Low-energy versus conventional residential buildings: cost and profit
    Zalejska-Jonsson, Agnieszka
    Lind, Hans
    Hintze, Staffan
    JOURNAL OF EUROPEAN REAL ESTATE RESEARCH, 2012, 5 (03) : 211 - 228