Laser Resonance Frequency Analysis: A Novel Measurement Approach to Evaluate Acetabular Cup Stability During Surgery

被引:13
|
作者
Kikuchi, Shunsuke [1 ]
Mikami, Katsuhiro [2 ]
Nakashima, Daisuke [1 ]
Kitamura, Toshiyuki [3 ]
Hasegawa, Noboru [3 ]
Nishikino, Masaharu [3 ]
Kanaji, Arihiko [1 ]
Nakamura, Masaya [1 ]
Nagura, Takeo [1 ]
机构
[1] Keio Univ, Dept Orthopaed Surg, Sch Med, Shinjuku Ku, 35 Shinanomachi, Tokyo 1608582, Japan
[2] Kindai Univ, Dept Biol Oriented Sci & Technol, 930 Nishi Mitani, Wakayama 6496493, Japan
[3] Natl Inst Quantum & Radiol Sci & Technol, Kansai Photon Sci Inst, 817 Umemidai, Kizugawa City, Kyoto 6190215, Japan
基金
日本学术振兴会;
关键词
total hip arthroplasty; implant stability; acetabular cup; laser; resonance frequency analysis; finite element method; TOTAL HIP-ARTHROPLASTY; ON-METAL BEARINGS; IMPLANT STABILITY; INITIAL STABILITY; FIXATION; FIT; VIVO;
D O I
10.3390/s19224876
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Artificial joint acetabular cup stability is essential for successful total hip arthroplasty. However, a quantitative evaluation approach for clinical use is lacking. We developed a resonance frequency analysis (RFA) system involving a laser system that is fully contactless. This study aimed to investigate the usefulness of laser RFA for evaluating acetabular cup stability. First, the finite element method was performed to determine the vibration mode for analysis. Second, the acetabular cup was press-fitted into a reamed polyurethane cavity that replicated the human acetabular roof. The implanted acetabular cup was vibrated with pulse laser irradiation and the induced vibration was detected with a laser Doppler vibrometer. The time domain signal from the vibrometer was analyzed by fast Fourier transform to obtain the vibration frequency spectrum. After laser RFA, the pull-down force of the acetabular cup was measured as conventional implant fixation strength. The frequency of the first highest amplitude between 2 kHz and 6 kHz was considered as the resonance peak frequency, and its relationship with the pull-down force was assessed. The peak frequency could predict the pull-down force (R-2 = 0.859, p < 0.000). Our findings suggest that laser RFA might be useful to measure acetabular cup stability during surgery.
引用
收藏
页数:12
相关论文
共 50 条
  • [21] Resonance-frequency-analysis and torque-measurement for evaluation of primary stability of dental implants.
    Al-Nawas, B
    Groetz, KA
    Brahm, R
    Wagner, W
    JOURNAL OF DENTAL RESEARCH, 2002, 81 : B255 - B255
  • [22] Resonance frequency analysis of one-stage dental implant stability during the osseointegration period
    Ersanli, S
    Karabuda, C
    Beck, F
    Leblebicioglu, B
    JOURNAL OF PERIODONTOLOGY, 2005, 76 (07) : 1066 - 1071
  • [23] Resonance Frequency Analysis to Evaluate the Effect of Different Drilling Techniques on Implant Stability at Different Time Intervals: A Randomized Clinical Trial
    Sunny, Greeshma
    Mishra, Sunil K.
    Chowdhary, Ramesh
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2022, 37 (05) : 1055 - +
  • [24] The influence of fixation in formalin on the measurement of stability of implants using resonance frequency analysis and Periotest M®: A study in a dog
    Doi, Kazuya
    Kajihara, Shiho
    Morita, Koji
    Makihara, Yusuke
    Okada, Shinsuke
    Akagawa, Yasumasa
    BRITISH JOURNAL OF ORAL & MAXILLOFACIAL SURGERY, 2014, 52 (01): : 29 - 33
  • [25] Machine Learning-Based Diagnosis in Laser Resonance Frequency Analysis for Implant Stability of Orthopedic Pedicle Screws
    Mikami, Katsuhiro
    Nemoto, Mitsutaka
    Nagura, Takeo
    Nakamura, Masaya
    Matsumoto, Morio
    Nakashima, Daisuke
    SENSORS, 2021, 21 (22)
  • [26] Resonance frequency analysis in bone-anchored hearing aids: Patient demographics and an approach to assess implant stability
    Kelkar, A.
    Johnson, I.
    CLINICAL OTOLARYNGOLOGY, 2018, 43 (05) : 1361 - 1363
  • [27] Relationship between cortical bone thickness and implant stability at the time of surgery and secondary stability after osseointegration measured using resonance frequency analysis
    Tanaka, Kenko
    Sailer, Irena
    Iwama, Ryosuke
    Yamauchi, Kensuke
    Nogami, Shinnosuke
    Yoda, Nobuhiro
    Takahashi, Tetsu
    JOURNAL OF PERIODONTAL AND IMPLANT SCIENCE, 2018, 48 (06): : 360 - 372
  • [28] Measurement of dental implant stability by resonance frequency analysis and damping capacity assessment: Comparison of both techniques in a clinical trial
    Zix, Juergen
    Hug, Stefan
    Kessler-Liechti, Gerda
    Mericske-Stern, Regina
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2008, 23 (03) : 525 - 530
  • [29] A novel approach to evaluate masonry arch stability on the basis of limit analysis theory and non-destructive geometric characterization
    Riveiro, B.
    Solla, M.
    de Arteaga, I.
    Arias, P.
    Morer, P.
    AUTOMATION IN CONSTRUCTION, 2013, 31 : 140 - 148
  • [30] Stability diagnosis of orthopedic implants based on resonance frequency analysis with fiber transmission of nanosecond laser pulse and acceleration sensor
    Mikami, Katsuhiro
    Nakashima, Daisuke
    Kikuchi, Shunsuke
    Kitamura, Toshiyuki
    Hasegawa, Noboru
    Nagura, Takeo
    Nishikino, Masaharu
    OPTICAL FIBERS AND SENSORS FOR MEDICAL DIAGNOSTICS AND TREATMENT APPLICATIONS XX, 2020, 11233