Relationship between cortical bone thickness and implant stability at the time of surgery and secondary stability after osseointegration measured using resonance frequency analysis

被引:23
|
作者
Tanaka, Kenko [1 ,2 ,3 ]
Sailer, Irena [2 ]
Iwama, Ryosuke [1 ]
Yamauchi, Kensuke [1 ,3 ]
Nogami, Shinnosuke [1 ]
Yoda, Nobuhiro [3 ]
Takahashi, Tetsu [1 ,3 ]
机构
[1] Tohoku Univ, Div Oral & Maxillofacial Surg, Dept Oral Med & Surg, Grad Sch Dent, Sendai, Miyagi, Japan
[2] Dent Med Univ Geneva, Univ Clin, Div Fixed Prosthodont & Biomat, Geneva, Switzerland
[3] Tohoku Univ Hosp, Dent Implant Ctr, Sendai, Miyagi, Japan
来源
关键词
Cortical bone thickness; Implant stability; Osseointegration; Resonance frequency analysis; TITANIUM IMPLANTS; LOADING PROTOCOLS; DENTAL IMPLANTS; OSSTELL MENTOR; GRAFTED BONE; DENSITY; SITES; OVERDENTURES; PLACEMENT; MAXILLA;
D O I
10.5051/jpis.2018.48.6.360
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: It has been suggested that resonance frequency analysis (RFA) can measure changes in the stability of dental implants during osseointegration. This retrospective study aimed to evaluate dental implant stability at the time of surgery (primary stability; PS) and secondary stability (SS) after ossseointegration using RFA, and to investigate the relationship between implant stability and cortical bone thickness. Methods: In total, 113 patients who attended the Tohoku University Hospital Dental Implant Center were included in this study. A total of 229 implants were placed in either the mandibular region (n=118) or the maxilla region (n=111), with bone augmentation procedures used in some cases. RFA was performed in 3 directions, and the lowest value was recorded. The preoperative thickness of cortical bone at the site of implant insertion was measured digitally using computed tomography, excluding cases of bone grafts and immediate implant placements. Results: The mean implant stability quotient (ISQ) was 69.34 +/- 9.43 for PS and 75.99 +/- 6.23 for SS. The mandibular group had significantly higher mean ISQ values than the maxillary group for both PS and SS (P<0.01). A significant difference was found in the mean ISQ values for PS between 1-stage and 2-stage surgery (P<0.5). The mean ISQ values in the non-augmentation group were higher than in the augmentation group for both PS and SS (P<0.01). A weak positive correlation was observed between cortical bone thickness and implant stability for both PS and SS in all cases (P<0.01). Conclusions: Based on the present study, the ISQ may be affected by implant position site, the use of a bone graft, and cortical bone thickness before implant therapy.
引用
收藏
页码:360 / 372
页数:13
相关论文
共 50 条
  • [1] Influence of Simulated Bone Quality and Cortical Bone Thickness on Implant Stability Detection Using Resonance Frequency and Damping Factor Analysis
    Feng, Sheng-Wei
    Lin, Che-Tong
    Chang, Wei-Jen
    Lee, Sheng-Yang
    Cheng, Chiang-Hui
    Huang, Haw-Ming
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2014, 29 (01) : 105 - 112
  • [2] Relationship between implant stability measured by resonance frequency analysis (RFA) and bone loss during early healing period
    Yang, Seung-Min
    Shin, Seung-Yun
    Kye, Seung-Beom
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2008, 105 (02): : E12 - E19
  • [3] The evaluation of implant stability measured by resonance frequency analysis in different bone types
    Sargolzaie, Naser
    Samizade, Sarah
    Arab, Hamidreza
    Ghanbari, Habibollah
    Khodadadifard, Leila
    Khajavi, Amin
    JOURNAL OF THE KOREAN ASSOCIATION OF ORAL AND MAXILLOFACIAL SURGEONS, 2019, 45 (01) : 29 - 33
  • [4] The Interrelation between Cortical Bone Thickness and Primary and Secondary Dental Implant Stability: a Systematic Review
    Al-Juboori, Halah
    Petronis, Zygimantas
    Razukevicius, Dainius
    JOMR-JOURNAL OF ORAL & MAXILLOFACIAL RESEARCH, 2024, 15 (04):
  • [5] Relationship between cortical bone thickness or computerized tomography-derived bone density values and implant stability
    Merheb, Joe
    Van Assche, Nele
    Coucke, Wim
    Jacobs, Reinhilde
    Naert, Ignace
    Quirynen, Marc
    CLINICAL ORAL IMPLANTS RESEARCH, 2010, 21 (06) : 612 - 617
  • [6] Influence of cortical bone thickness and implant length on implant stability at the time of surgery - clinical, prospective, biomechanical, and imaging study
    Miyamoto, I
    Tsuboi, Y
    Wada, E
    Suwa, H
    Iizuka, T
    BONE, 2005, 37 (06) : 776 - 780
  • [7] Relationship between the CT Value and Cortical Bone Thickness at Implant Recipient Sites and Primary Implant Stability with Comparison of Different Implant Types
    Howashi, Miori
    Tsukiyama, Yoshihiro
    Ayukawa, Yasunori
    Isoda-Akizuki, Kei
    Kihara, Masafumi
    Imai, Yu
    Sogo, Motofumi
    Koyano, Kiyoshi
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2016, 18 (01) : 107 - 116
  • [8] An analysis of correlation between the cortical bone thickness and primary implant stability using non-destructive methods.
    Yi, Y. J.
    Yoon, D. J.
    Jung, J. C.
    Yang, J. H.
    JOURNAL OF DENTAL RESEARCH, 2003, 82 : B327 - B327
  • [9] Influence of Osseointegration Degree and Pattern on Resonance Frequency in the Assessment of Dental Implant Stability Using Finite Element Analysis
    Deng, Bin
    Tan, Keson B.
    Liu, Gui Rong
    Lu, Yi
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2008, 23 (06) : 1082 - 1088
  • [10] The Correlation Between Crestal Bone Resorption and Implant Stability During Healing Period Using Resonance Frequency Analysis
    Al-Juboori, Mohammed Jasim
    Bin AbdulRahaman, Shafluzan
    Hassan, Akram
    IMPLANT DENTISTRY, 2013, 22 (04) : 351 - 355