Laser Resonance Frequency Analysis: A Novel Measurement Approach to Evaluate Acetabular Cup Stability During Surgery

被引:13
|
作者
Kikuchi, Shunsuke [1 ]
Mikami, Katsuhiro [2 ]
Nakashima, Daisuke [1 ]
Kitamura, Toshiyuki [3 ]
Hasegawa, Noboru [3 ]
Nishikino, Masaharu [3 ]
Kanaji, Arihiko [1 ]
Nakamura, Masaya [1 ]
Nagura, Takeo [1 ]
机构
[1] Keio Univ, Dept Orthopaed Surg, Sch Med, Shinjuku Ku, 35 Shinanomachi, Tokyo 1608582, Japan
[2] Kindai Univ, Dept Biol Oriented Sci & Technol, 930 Nishi Mitani, Wakayama 6496493, Japan
[3] Natl Inst Quantum & Radiol Sci & Technol, Kansai Photon Sci Inst, 817 Umemidai, Kizugawa City, Kyoto 6190215, Japan
基金
日本学术振兴会;
关键词
total hip arthroplasty; implant stability; acetabular cup; laser; resonance frequency analysis; finite element method; TOTAL HIP-ARTHROPLASTY; ON-METAL BEARINGS; IMPLANT STABILITY; INITIAL STABILITY; FIXATION; FIT; VIVO;
D O I
10.3390/s19224876
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Artificial joint acetabular cup stability is essential for successful total hip arthroplasty. However, a quantitative evaluation approach for clinical use is lacking. We developed a resonance frequency analysis (RFA) system involving a laser system that is fully contactless. This study aimed to investigate the usefulness of laser RFA for evaluating acetabular cup stability. First, the finite element method was performed to determine the vibration mode for analysis. Second, the acetabular cup was press-fitted into a reamed polyurethane cavity that replicated the human acetabular roof. The implanted acetabular cup was vibrated with pulse laser irradiation and the induced vibration was detected with a laser Doppler vibrometer. The time domain signal from the vibrometer was analyzed by fast Fourier transform to obtain the vibration frequency spectrum. After laser RFA, the pull-down force of the acetabular cup was measured as conventional implant fixation strength. The frequency of the first highest amplitude between 2 kHz and 6 kHz was considered as the resonance peak frequency, and its relationship with the pull-down force was assessed. The peak frequency could predict the pull-down force (R-2 = 0.859, p < 0.000). Our findings suggest that laser RFA might be useful to measure acetabular cup stability during surgery.
引用
收藏
页数:12
相关论文
共 50 条
  • [11] Use of resonance frequency analysis to evaluate the effects of surface properties on the stability of different implants
    Gursoytrak, Burcu
    Ataoglu, Hanife
    CLINICAL ORAL IMPLANTS RESEARCH, 2020, 31 (03) : 239 - 245
  • [12] In vitro comparative analysis of two resonance frequency measurement devices: Osstell implant stability coefficient and Penguin resonance frequency analysis
    Herrero-Climent, Mariano
    Falcao, Artur
    Lopez-Jarana, Paula
    Diaz-Castro, Carmen M.
    Rios-Carrasco, Blanca
    Vicente Rios-Santos, Jose
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2019, 21 (06) : 1124 - 1131
  • [13] Relevance of resonance frequency analysis to evaluate dental implant stability: simulation and histomorphometrical animal experiments
    Ito, Yoshihiro
    Sato, Daisuke
    Yoneda, Satoshi
    Ito, Daisuke
    Kondo, Hisatomo
    Kasugai, Shohei
    CLINICAL ORAL IMPLANTS RESEARCH, 2008, 19 (01) : 9 - 14
  • [14] Resonance frequency analysis of dental implant stability during the healing period
    Boronat Lopez, Araceli
    Balaguer Martinez, Jose
    Lamas Pelayo, Joana
    Carrillo Garcia, Celia
    Penarrocha Diago, Miguel
    MEDICINA ORAL PATOLOGIA ORAL Y CIRUGIA BUCAL, 2008, 13 (04): : E244 - E247
  • [15] Aeolus High Energy UV Laser wavelength measurement and frequency stability analysis
    Mondin, Linda
    Bravetti, Paolo
    INTERNATIONAL CONFERENCE ON SPACE OPTICS-ICSO 2014, 2014, 10563
  • [16] Torsional resonance frequency analysis: a novel method for assessment of dental implant stability
    Tang, Yu-Long
    Li, Bing
    Jin, Wei
    Li, De-Hua
    CLINICAL ORAL IMPLANTS RESEARCH, 2015, 26 (06) : 615 - 622
  • [17] Measurement of Primary and Secondary Stability of Dental Implants by Resonance Frequency Analysis Method in Mandible
    Shokri, Mehran
    Daraeighadikolaei, Arash
    INTERNATIONAL JOURNAL OF DENTISTRY, 2013, 2013
  • [18] Laser resonance frequency analysis of pedicle screw stability: A cadaveric model bone study
    Nakashima, Daisuke
    Mikami, Katsuhiro
    Kikuchi, Shunsuke
    Nishikino, Masaharu
    Kitamura, Toshiyuki
    Hasegawa, Noboru
    Matsumoto, Morio
    Nakamura, Masaya
    Nagura, Takeo
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2021, 39 (11) : 2474 - 2484
  • [19] A Critique of Resonance Frequency Analysis and a Novel Method for Quantifying Dental Implant Stability in Vitro
    Khouja, Naseeba
    Tai, Wei Che
    Shen, I. Y.
    Sorensen, John A.
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2019, 34 (03) : 595 - 603
  • [20] Resonance frequency analysis of osseo-integrated implants for bone conduction in a pediatric population - A novel approach for assessing stability for early loading
    McLarnon, Claire
    Johnson, Ian
    Davison, Tom
    Hill, John
    Henderson, Beverly
    Leese, Denise
    Marley, Suzanne
    INTERNATIONAL JOURNAL OF PEDIATRIC OTORHINOLARYNGOLOGY, 2014, 78 (04) : 641 - 644