Right ventricular assist system feedback flow control parameter for a rotary blood pump

被引:5
|
作者
Yoshikawa, M
Nakata, K
Nonaka, K
Linneweber, J
Kawahito, S
Takano, T
Shulte-Eistrup, S
Maeda, T
Glueck, J
Schima, H
Wolner, E
Nosé, Y
机构
[1] Baylor Coll Med, Houston, TX 77030 USA
[2] Univ Vienna, Vienna, Austria
关键词
right ventricular assist system; implantable right ventricular assist device; Gyro pump; flow control; feedback parameter; exercise test;
D O I
10.1046/j.1525-1594.2000.06579.x
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
At least 25-30% of patients with a permanent implantable left ventricular assist device (LVAD) experience right ventricular failure; therefore, an implantable biventricular assist system (BiVAS) with small centrifugal pumps is being developed. Many institutions are focusing and developing a control system for a left ventricular assist system (LVAS) with rotary blood pumps. These authors feel that the right ventricular assist system (RVAS) with rotary blood pumps should be developed simultaneously. A literature search indicated no recent reports on the effect of hemodynamics and exercise with this type of nonpulsatile implantable RVAS. In this study, a calf with an implantable right ventricular assist system (RVAS) was subjected to 30 min of exercise on a treadmill at 1.5 mph, resulting in excellent hemodynamics. The input voltage remained unchanged. Hemodynamic recordings were taken every 5 min throughout the testing period, and blood gas analysis was done every 10 min. Oxygen uptake (VO2), oxygen delivery (DO2), and oxygen extraction (O2ER) were calculated and analyzed. Two different pump flows were investigated: Group 1 low assist (<3.5 L/min) and Group 2 high assist (>3.5 L/min). In both groups, the RVAS flow rates were unchanged while the pulmonary artery (PA) flow increased during exercise; also, the heart rate and right atrial pressure (RAP) increased during exercise. There were no significant differences in the 2 groups. The PA flow correlates to the heart rate during exercise. In all of the tests, the VO2 and DO2 increased during exercise. Regarding VO2, no changes were observed during the different flow conditions; however, the DO2 of Group 2 was higher than that of Group 1. Because the implantable RVAS did not have pump flow changes during the test conditions, it was necessary to incorporate a flow control system for the implantable RVAS. During exercise with an implantable RVAS rotary blood pump, incorporating the heart rate and VO2 as feedback parameters is feasible for controlling the flow rate.
引用
收藏
页码:659 / 666
页数:8
相关论文
共 50 条
  • [21] Rotary Blood Pump Control Strategy for Preventing Left Ventricular Suction
    Wang, Yu
    Koenig, Steven C.
    Slaughter, Mark S.
    Giridharan, Guruprasad A.
    [J]. ASAIO JOURNAL, 2015, 61 (01) : 21 - 30
  • [22] TOTALLY IMPLANTABLE VENTRICULAR ASSIST SYSTEM USING A VIBRATING FLOW PUMP
    NITTA, S
    YAMBE, T
    SONOBE, T
    NAGANUMA, S
    KAKINUMA, Y
    KOBAYASHI, S
    TANAKA, M
    MATSUKI, H
    ABE, K
    YOSHIZAWA, M
    KASAI, T
    HASHIMOTO, H
    [J]. ARTIFICIAL ORGANS, 1995, 19 (07) : 676 - 679
  • [23] Motor feedback physiological control for a continuous flow ventricular assist device
    Waters, T
    Allaire, P
    Tao, G
    Adams, M
    Bearnson, G
    Wei, N
    Hilton, E
    Baloh, M
    Olsen, D
    Khanwilkar, P
    [J]. ARTIFICIAL ORGANS, 1999, 23 (06) : 480 - 486
  • [24] HEMODYNAMIC-EFFECTS OF RIGHT VENTRICULAR ASSIST PUMP
    CHIANG, BY
    YE, CH
    GUO, YJ
    WANG, S
    [J]. ARTIFICIAL ORGANS, 1987, 11 (04) : 326 - 326
  • [25] Physiological control of rotary left ventricular assist device
    Yi, Wu
    [J]. PROCEEDINGS OF THE 26TH CHINESE CONTROL CONFERENCE, VOL 6, 2007, : 469 - 474
  • [26] Development of a Pump Flow Estimator for Rotary Blood Pumps to Enhance Monitoring of Ventricular Function
    Granegger, Marcus
    Moscato, Francesco
    Casas, Fernando
    Wieselthaler, Georg
    Schima, Heinrich
    [J]. ARTIFICIAL ORGANS, 2012, 36 (08) : 691 - 699
  • [27] Modeling and simulation of a blood pump for the development of a left ventricular assist system controller
    Yu, YC
    Boston, JR
    Simaan, MA
    Miller, PJ
    Antaki, JF
    [J]. KYBERNETIKA, 1999, 35 (05) : 651 - 664
  • [28] Blood damage in Left Ventricular Assist Devices: Pump thrombosis or system thrombosis?
    Selmi, Matteo
    Chiu, Wei-Che
    Chivukula, Venkat Keshav
    Melisurgo, Giulio
    Beckman, Jennifer Ann
    Mahr, Claudius
    Aliseda, Alberto
    Votta, Emiliano
    Redaelli, Alberto
    Slepian, Marvin J.
    Bluestein, Danny
    Pappalardo, Federico
    Consolo, Filippo
    [J]. INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2019, 42 (03): : 113 - 124
  • [29] In Vitro Hemocompatibility Evaluation of Modified Rotary Left to Right Ventricular Assist Devices in Pulmonary Flow Conditions
    Chan, Chris Hoi Houng
    Nandakumar, Deepika
    Balletti, Nicoletta
    Horobin, Jarod
    Wu, Eric Lee-Jan
    Bouquet, Mahe
    Stephens, Andrew
    Pauls, Jo P.
    Tansley, Geoff
    Fraser, John F.
    Simmonds, Michael J.
    Gregory, Shaun D.
    [J]. ASAIO JOURNAL, 2020, 66 (06) : 637 - 644
  • [30] Intrathoracic implantation of a continuous flow left ventricular assist device - the microdiagonal blood pump
    Christiansen, S.
    Redmann, K.
    Autschbach, R.
    [J]. JOURNAL OF CARDIOVASCULAR SURGERY, 2006, 47 (03): : 329 - 335