Physiological control of rotary left ventricular assist device

被引:0
|
作者
Yi, Wu [1 ]
机构
[1] Penn State Univ, Dept Mech Engn, Behrend Coll, Erie, PA 16563 USA
关键词
physiological control; rotary artificial heart pump; left ventricular assist device; pump head; adaptive control;
D O I
暂无
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
In rotary left ventricular assist device (LVAD), physiological control system is the element to automatically regulate the pump speed to ensure enough perfusion of patients. In this paper, the design of the physiological control system of rotary LVADs is reviewed first, such as criteria of physiological control system, sensors/signals, and control algorithms. Then the design of an adaptive optimal controller for permanent LVADs is discussed. A Matlab simulation program and an experimental mock circulatory loop are employed as test environments for the controller. Different physiological conditions, such as the variation of left ventricular failures and the variation of activities are simulated to study the performance of the designed physiological controller. Simulation and experimental results consistently show that the abnormal hemodynamic variables of a congestive heart failure patient are restored back to the normal physiological range by the designed controller.
引用
下载
收藏
页码:469 / 474
页数:6
相关论文
共 50 条
  • [1] A variable gain physiological controller for a rotary left ventricular assist device
    Silva, Luis F., V
    Cordeiro, Thiago D.
    Lima, Antonio M. N.
    2021 43RD ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE & BIOLOGY SOCIETY (EMBC), 2021, : 5606 - 5609
  • [2] Control Method of a Rotary Blood Pump for a Left Ventricular Assist Device
    Petukhov, D. S.
    Telyshev, D. V.
    Selishchev, S. V.
    SOVREMENNYE TEHNOLOGII V MEDICINE, 2016, 8 (01) : 28 - 33
  • [3] Feedback Control of a Rotary Left Ventricular Assist Device Supporting a failing Cardiovascular System
    Wang, Yu
    Faragallah, George
    Divo, Eduardo
    Simaan, Marwan A.
    2012 AMERICAN CONTROL CONFERENCE (ACC), 2012, : 1137 - 1142
  • [4] Evaluation of Physiological Control Systems for Rotary Left Ventricular Assist Devices: An In-Vitro Study
    Jo P. Pauls
    Michael C. Stevens
    Nicole Bartnikowski
    John F. Fraser
    Shaun D. Gregory
    Geoff Tansley
    Annals of Biomedical Engineering, 2016, 44 : 2377 - 2387
  • [5] A Novel Multi-objective Physiological Control System for Rotary Left Ventricular Assist Devices
    Anastasios Petrou
    Marcial Monn
    Mirko Meboldt
    Marianne Schmid Daners
    Annals of Biomedical Engineering, 2017, 45 : 2899 - 2910
  • [6] A Novel Multi-objective Physiological Control System for Rotary Left Ventricular Assist Devices
    Petrou, Anastasios
    Monn, Marcial
    Meboldt, Mirko
    Daners, Marianne Schmid
    ANNALS OF BIOMEDICAL ENGINEERING, 2017, 45 (12) : 2899 - 2910
  • [7] Evaluation of Physiological Control Systems for Rotary Left Ventricular Assist Devices: An In-Vitro Study
    Pauls, Jo P.
    Stevens, Michael C.
    Bartnikowski, Nicole
    Fraser, John F.
    Gregory, Shaun D.
    Tansley, Geoff
    ANNALS OF BIOMEDICAL ENGINEERING, 2016, 44 (08) : 2377 - 2387
  • [8] Physiological Control of Pulsatile and Rotary Pediatric Ventricular Assist Devices
    Melo, T. R.
    Cordeiro, T. D.
    Cestari, I. A.
    da Rocha Neto, J. S.
    Lima, A. M. N.
    XXVII BRAZILIAN CONGRESS ON BIOMEDICAL ENGINEERING, CBEB 2020, 2022, : 213 - 219
  • [9] A Sensorless Physiological Control Algorithm for Left Ventricular Assist Device for Heart Failure Patients
    Bakouri, Mohsen A.
    Savkin, Andrey V.
    Alomari, Abdul-Hakeem H.
    2014 IEEE CONFERENCE ON CONTROL APPLICATIONS (CCA), 2014, : 1017 - 1022
  • [10] In Vitro Evaluation of Aortic Insufficiency With a Rotary Left Ventricular Assist Device
    Gregory, Shaun D.
    Stevens, Michael C.
    Wu, Eric
    Fraser, John F.
    Timms, Daniel
    ARTIFICIAL ORGANS, 2013, 37 (09) : 802 - 809