Establishing national diagnostic reference levels (DRLs) for computed tomography in Egypt

被引:62
|
作者
Salama, Dina Husseiny [1 ]
Vassileva, Jenia [2 ]
Mahdaly, Gamal [3 ]
Shawki, Mona [4 ]
Salama, Ahmad [5 ]
Gilley, Debbie [2 ]
Rehani, Madan Mohan [6 ,7 ]
机构
[1] Egyptian Atom Energy Author, Cairo, Egypt
[2] IAEA, Vienna, Austria
[3] Experta Med, Cairo, Egypt
[4] Alexandria Fac Med, Alexandria, Egypt
[5] Ain Shams Fac Med, Cairo, Egypt
[6] Massachusetts Gen Hosp, Boston, MA 02114 USA
[7] Harvard Med Sch, Boston, MA USA
关键词
DRLs in Egypt; Computed tomography (CT) DRLs; Patient doses African country; National dose survey Egypt; CT EXAMINATIONS;
D O I
10.1016/j.ejmp.2017.05.050
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives: To establish national diagnostic reference levels (DRLs) in Egypt for computed tomography (CT) examinations of adults and identify the potential for optimization. Methods: Data from 3762 individual patient's undergoing CT scans of head, chest (high resolution), abdomen, abdomen-pelvis, chest-abdomen-pelvis and CT angiography (aorta and both lower limbs) examinations in 50 CT facilities were collected. This represents 20% of facilities in the country and all of the 27 Governorates. Results were compared with DRLs of UK, USA, Canada, Japan, Australia and France. Results: The Egyptian DRLs for CTDIvol in mGy are for head: 30, chest (high resolution): 22, abdomen (liver metastasis): 31, abdomen-pelvis: 31, chest-abdomen-pelvis: 33 and CT angiography (aorta and lower limbs): 37. The corresponding DRLs for DLP in mGy. cm are 1360, 420, 1425, 1325, 1320 and 1320. For head CT, the Egyptian DRL for CTDIvol is 2-3 times lower than the DRLs from other countries. However, the DRL in terms of DLP is in the same range or higher as compared to others. The Egyptian DRL for chest CT (high resolution) is similar to others for DLP but higher for CTDIvol. For abdomen and abdomen-pelvis DRLs for CTDIvol are higher than others. For DLP, the DRLs for abdomen are higher than DRL in UK and lower than those in Japan, while for abdomen-pelvis they are higher than other countries. Conclusion: Despite lower DRLs for CTDIvol, an important consistent problem appears to be higher scan range as DRLs for DLP are higher. (C) 2017 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:16 / 24
页数:9
相关论文
共 50 条
  • [41] ESTABLISHING LOCAL DIAGNOSTIC REFERENCE LEVELS FOR ROUTINE COMPUTED TOMOGRAPHY EXAMINATIONS IN JIMMA UNIVERSITY MEDICAL CENTER SOUTH WEST ETHIOPIA
    Zewdu, Mesfin
    Kadir, Elias
    Tesfaye, Million
    Berhane, Melkamu
    [J]. RADIATION PROTECTION DOSIMETRY, 2021, 193 (3-4) : 200 - 206
  • [42] Diagnostic Reference Levels based on clinical indications in computed tomography: a literature review
    Graciano Paulo
    John Damilakis
    Virginia Tsapaki
    Alexander A. Schegerer
    Jacques Repussard
    Werner Jaschke
    Guy Frija
    [J]. Insights into Imaging, 11
  • [43] Reporting Diagnostic Reference Levels for Paediatric Patients Undergoing Brain Computed Tomography
    Alhailiy, Ali
    Alkhybari, Essam
    Alghamdi, Sultan
    Fisal, Nada
    Aldosari, Sultan
    Albeshan, Salman
    [J]. TOMOGRAPHY, 2023, 9 (06) : 2029 - 2038
  • [44] DIAGNOSTIC REFERENCE LEVELS FOR PAEDIATRIC HEAD COMPUTED TOMOGRAPHY IN MOROCCO: A NATIONWIDE SURVEY
    Benmessaoud, M.
    Dadouch, A.
    Talbi, M.
    Tahiri, M.
    El-ouardi, Y.
    [J]. RADIATION PROTECTION DOSIMETRY, 2020, 191 (04) : 400 - 408
  • [45] Diagnostic reference levels for routine computed tomography angiography examinations: a systematic review
    Alhailiy, Ali Bahny
    [J]. EGYPTIAN JOURNAL OF RADIOLOGY AND NUCLEAR MEDICINE, 2024, 55 (01):
  • [46] Establishment of diagnostic reference levels in low-dose renal computed tomography
    Rawashdeh, Mohammad
    Saade, Charbel
    [J]. ACTA RADIOLOGICA, 2023, 64 (02) : 829 - 836
  • [47] Estimation of diagnostic reference levels for children computed tomography: A study in Tehran, Iran
    Afzalipour, R.
    Abdollahi, H.
    Hajializadeh, M. S.
    Jafari, S.
    Mahdavi, S. R.
    [J]. INTERNATIONAL JOURNAL OF RADIATION RESEARCH, 2019, 17 (03): : 407 - 413
  • [48] Diagnostic Reference Levels based on clinical indications in computed tomography: a literature review
    Paulo, Graciano
    Damilakis, John
    Tsapaki, Virginia
    Schegerer, Alexander A.
    Repussard, Jacques
    Jaschke, Werner
    Frija, Guy
    [J]. INSIGHTS INTO IMAGING, 2020, 11 (01)
  • [49] Establishment of diagnostic reference levels in computed tomography for select procedures in Pudhuchery, India
    Saravanakumar, A.
    Vaideki, K.
    Govindarajan, K. N.
    Jayakumar, S.
    [J]. JOURNAL OF MEDICAL PHYSICS, 2014, 39 (01) : 50 - 55
  • [50] Diagnostic reference levels for chest computed tomography in children as a function of patient size
    Bos, Denise
    Zensen, Sebastian
    Opitz, Marcel K.
    Haubold, Johannes
    Nassenstein, Kai
    Kinner, Sonja
    Schweiger, Bernd
    Forsting, Michael
    Wetter, Axel
    Guberina, Nika
    [J]. PEDIATRIC RADIOLOGY, 2022, 52 (08) : 1446 - 1455