Establishing national diagnostic reference levels (DRLs) for computed tomography in Egypt

被引:62
|
作者
Salama, Dina Husseiny [1 ]
Vassileva, Jenia [2 ]
Mahdaly, Gamal [3 ]
Shawki, Mona [4 ]
Salama, Ahmad [5 ]
Gilley, Debbie [2 ]
Rehani, Madan Mohan [6 ,7 ]
机构
[1] Egyptian Atom Energy Author, Cairo, Egypt
[2] IAEA, Vienna, Austria
[3] Experta Med, Cairo, Egypt
[4] Alexandria Fac Med, Alexandria, Egypt
[5] Ain Shams Fac Med, Cairo, Egypt
[6] Massachusetts Gen Hosp, Boston, MA 02114 USA
[7] Harvard Med Sch, Boston, MA USA
关键词
DRLs in Egypt; Computed tomography (CT) DRLs; Patient doses African country; National dose survey Egypt; CT EXAMINATIONS;
D O I
10.1016/j.ejmp.2017.05.050
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives: To establish national diagnostic reference levels (DRLs) in Egypt for computed tomography (CT) examinations of adults and identify the potential for optimization. Methods: Data from 3762 individual patient's undergoing CT scans of head, chest (high resolution), abdomen, abdomen-pelvis, chest-abdomen-pelvis and CT angiography (aorta and both lower limbs) examinations in 50 CT facilities were collected. This represents 20% of facilities in the country and all of the 27 Governorates. Results were compared with DRLs of UK, USA, Canada, Japan, Australia and France. Results: The Egyptian DRLs for CTDIvol in mGy are for head: 30, chest (high resolution): 22, abdomen (liver metastasis): 31, abdomen-pelvis: 31, chest-abdomen-pelvis: 33 and CT angiography (aorta and lower limbs): 37. The corresponding DRLs for DLP in mGy. cm are 1360, 420, 1425, 1325, 1320 and 1320. For head CT, the Egyptian DRL for CTDIvol is 2-3 times lower than the DRLs from other countries. However, the DRL in terms of DLP is in the same range or higher as compared to others. The Egyptian DRL for chest CT (high resolution) is similar to others for DLP but higher for CTDIvol. For abdomen and abdomen-pelvis DRLs for CTDIvol are higher than others. For DLP, the DRLs for abdomen are higher than DRL in UK and lower than those in Japan, while for abdomen-pelvis they are higher than other countries. Conclusion: Despite lower DRLs for CTDIvol, an important consistent problem appears to be higher scan range as DRLs for DLP are higher. (C) 2017 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:16 / 24
页数:9
相关论文
共 50 条
  • [11] Establishment of national diagnostic reference levels as guidelines for computed tomography radiation in Jordan
    Al Ewaidat, Haytham
    Balawi, Sara
    Bataineh, Ziad
    Al-Dwairi, Ahmed
    Al-Khalily, Majd
    Azez, Khalaf Abdel
    Almakhadmeh, Ali
    [J]. INTERNATIONAL JOURNAL OF IMAGING SYSTEMS AND TECHNOLOGY, 2023, 33 (04) : 1223 - 1234
  • [12] Diagnostic reference levels for paediatric computed tomography
    Vawda, Zakariya
    Pitcher, Richard
    Akudugu, John
    Groenewald, Willem
    [J]. SA JOURNAL OF RADIOLOGY, 2015, 19 (02):
  • [13] A Review of Diagnostic Reference Levels in Computed Tomography
    Dawd, Jemal Edris
    Ozsahin, Dilber Uzun
    Ozsahin, Ilker
    [J]. CURRENT MEDICAL IMAGING, 2022, 18 (06) : 623 - 632
  • [14] Survey of computed tomography doses and establishment of national diagnostic reference levels in the Republic of Belarus
    Kharuzhyk, S. A.
    Matskevich, S. A.
    Filjustin, A. E.
    Bogushevich, E. V.
    Ugolkova, S. A.
    [J]. RADIATION PROTECTION DOSIMETRY, 2010, 139 (1-3) : 367 - 370
  • [15] Adult Computed Tomography examinations in Uganda: Towards determining the National Diagnostic Reference Levels
    Geoffrey Erem
    Faith Ameda
    Caroline Otike
    William Olwit
    Aloysius G. Mubuuke
    Cyril Schandorf
    Akisophel Kisolo
    Michael G. Kawooya
    [J]. BMC Medical Imaging, 22
  • [16] Establishment of national diagnostic reference levels for radiotherapy computed tomography simulation procedures in Slovenia
    Zalokar, Nika
    Marcius, Valerija Zager
    Mekis, Nejc
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2020, 127
  • [17] Adult Computed Tomography examinations in Uganda: Towards determining the National Diagnostic Reference Levels
    Erem, Geoffrey
    Ameda, Faith
    Otike, Caroline
    Olwit, William
    Mubuuke, Aloysius G.
    Schandorf, Cyril
    Kisolo, Akisophel
    Kawooya, Michael G.
    [J]. BMC MEDICAL IMAGING, 2022, 22 (01)
  • [18] Establishment of national diagnostic reference levels in dental cone beam computed tomography in Switzerland
    Deleu, Marine
    Dagassan, Dorothea
    Berg, Isabelle
    Bize, Julie
    Dula, Karl
    Lenoir, Vincent
    Ott, Barbara
    Ott, Julien G.
    Verdun, Francis R.
    Weber, Robert
    Ziglinas, Panagiotis
    Zingariello, Cesare
    Merce, Marta Sans
    [J]. DENTOMAXILLOFACIAL RADIOLOGY, 2020, 49 (06)
  • [19] Establishment of diagnostic reference levels in cardiac computed tomography
    Rawashdeh, Mohammad
    Saade, Charbel
    Zaitoun, Maha
    Abdelrahman, Mostafa
    Brennan, Patrick
    Alewaidat, Haytham
    McEntee, Mark F.
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2019, 20 (10): : 181 - 186
  • [20] The establishment of computed tomography diagnostic reference levels in Portugal
    Santos, Joana
    Foley, Shane
    Paulo, Graciano
    McEntee, Mark F.
    Rainford, Louise
    [J]. RADIATION PROTECTION DOSIMETRY, 2014, 158 (03) : 307 - 317