Reporting Diagnostic Reference Levels for Paediatric Patients Undergoing Brain Computed Tomography

被引:0
|
作者
Alhailiy, Ali [1 ]
Alkhybari, Essam [1 ]
Alghamdi, Sultan [2 ]
Fisal, Nada [3 ]
Aldosari, Sultan [4 ]
Albeshan, Salman [5 ]
机构
[1] Prince Sattam Bin Abdulaziz Univ, Coll Appl Med Sci, Dept Radiol & Med Imaging, Alkharj 11942, Saudi Arabia
[2] Secur Force Hosp, Radiol & Nucl Med Dept, POB 3643, Riyadh 11481, Saudi Arabia
[3] King Fahad Med City, Radiol Dept, POB 59042, Riyadh 11525, Saudi Arabia
[4] King Saud Med City, Med Imaging Dept, Riyadh 12746, Saudi Arabia
[5] King Saud Univ, Coll Appl Med Sci, Radiol Sci Dept, POB 145111, Riyadh 4545, Saudi Arabia
关键词
computed tomography; diagnostic reference levels; paediatric CT imaging; weight groups; CT;
D O I
10.3390/tomography9060159
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Brain computed tomography (CT) is a diagnostic imaging tool routinely used to assess all paediatric neurologic disorders and other head injuries. Despite the continuous development of paediatric CT imaging, radiation exposure remains a concern. Using diagnostic reference levels (DRLs) helps to manage the radiation dose delivered to patients, allowing one to identify an unusually high dose. In this paper, we propose DRLs for paediatric brain CT examinations in Saudi clinical practices and compare the findings with those of other reported DRL studies. Data including patient and scanning protocols were collected retrospectively from three medical cities for a total of 225 paediatric patients. DRLs were derived for four different age groupings. The resulting DRL values for the dose-length product (DLP) for the age groups of newborns (0-1 year), 1-y-old (1-5 years), 5-y-old (5-10 years) and 10-y-old (10-15 years) were 404 mGy cm, 560 mGy cm, 548 mGy cm, and 742 mGy cm, respectively. The DRLs for paediatric brain CT imaging are comparable to or slightly lower than other DRLs due to the current use of dose optimisation strategies. This study emphasises the need for an international standardisation for the use of weight group categories in DRL establishment for paediatric care in order to provide a more comparable measurement of dose quantities across different hospitals globally.
引用
收藏
页码:2029 / 2038
页数:10
相关论文
共 50 条
  • [1] Diagnostic reference levels for paediatric computed tomography
    Vawda, Zakariya
    Pitcher, Richard
    Akudugu, John
    Groenewald, Willem
    SA JOURNAL OF RADIOLOGY, 2015, 19 (02):
  • [2] Paediatric diagnostic reference levels in computed tomography: a systematic review
    Satharasinghe, D. M.
    Jeyasugiththan, J.
    Wanninayake, W. M. N. M. B.
    Pallewatte, A. S.
    JOURNAL OF RADIOLOGICAL PROTECTION, 2021, 41 (01) : R1 - R27
  • [3] Diagnostic Reference Level of Paediatric Computed Tomography Brain Examinations
    Abdelaziz, Ikhlas
    BIOSCIENCE RESEARCH, 2021, 18 (01): : 477 - 487
  • [5] Establishing national paediatric computed tomography diagnostic reference levels in Ghana
    Shirazu, Issahaku
    Sackey, Theophilus A.
    Edziah, Raymond
    Boateng, Yaw Mensah
    Schandorf, Cyril.
    HEALTH AND TECHNOLOGY, 2024, : 1187 - 1198
  • [6] Paediatric computed tomography diagnostic reference levels in Africa: A systematic review
    Gyan, Emmanuel
    Subaar, Christiana
    Edusei, George
    Antwi Nyarko, Linda
    JOURNAL OF MEDICAL RADIATION SCIENCES, 2024,
  • [7] 2021 NATIONAL DIAGNOSTIC REFERENCE LEVELS FOR PAEDIATRIC COMPUTED TOMOGRAPHY IN EGYPT
    Abdou, Sayed E.
    Salama, Dina H.
    Ahmad, Khaled A.
    Sallam, Abdelsattar M.
    El-Sayed, El-Sayed Mahmoud
    Talaat, M. S.
    El-Farrash, Rania A.
    Vassileva, J.
    RADIATION PROTECTION DOSIMETRY, 2022, 198 (07) : 423 - 433
  • [8] Local diagnostic reference levels for paediatric chest computed tomography in Morocco
    Benmessaoud, Mounir
    Dadouch, Ahmed
    Maghnouj, Abdelmajid
    Lemmassi, Assiya
    Ouaggou, Ibrahim Ait
    Ouhadda, Hassan
    El-Ouardi, Youssef
    RADIATION PHYSICS AND CHEMISTRY, 2023, 206
  • [9] A STUDY TO ESTABLISH INTERNATIONAL DIAGNOSTIC REFERENCE LEVELS FOR PAEDIATRIC COMPUTED TOMOGRAPHY
    Vassileva, J.
    Rehani, M.
    Kostova-Lefterova, D.
    Al-Naemi, H. M.
    Al Suwaidi, J. S.
    Arandjic, D.
    Bashier, E. H. O.
    Kodlulovich Renha, S.
    El-Nachef, L.
    Aguilar, J. G.
    Gershan, V.
    Gershkevitsh, E.
    Gruppetta, E.
    Hustuc, A.
    Jauhari, A.
    Kharita, Mohammad Hassan
    Khelassi-Toutaoui, N.
    Khosravi, H. R.
    Khoury, H.
    Kralik, I.
    Mahere, S.
    Mazuoliene, J.
    Mora, P.
    Muhogora, W.
    Muthuvelu, P.
    Nikodemova, D.
    Novak, L.
    Pallewatte, A.
    Pekarovic, D.
    Shaaban, M.
    Shelly, E.
    Stepanyan, K.
    Thelsy, N.
    Visrutaratna, P.
    Zaman, A.
    RADIATION PROTECTION DOSIMETRY, 2015, 165 (1-4) : 70 - 80
  • [10] DIAGNOSTIC REFERENCE LEVELS FOR PAEDIATRIC HEAD COMPUTED TOMOGRAPHY IN MOROCCO: A NATIONWIDE SURVEY
    Benmessaoud, M.
    Dadouch, A.
    Talbi, M.
    Tahiri, M.
    El-ouardi, Y.
    RADIATION PROTECTION DOSIMETRY, 2020, 191 (04) : 400 - 408