Diagnosis and management of iatrogenic cardiac perforation caused by pacemaker and defibrillator leads

被引:46
|
作者
Rajkumar, Christopher A. [1 ]
Claridge, Simon [2 ]
Jackson, Tom [2 ]
Behar, Jonathan [2 ]
Johnson, Jonathan [2 ]
Sohal, Manav [2 ]
Amraoui, Sana [1 ]
Nair, Arjun [3 ]
Preston, Rebecca [3 ]
Gill, Jaswinder [1 ]
Rajani, Ronak [1 ,3 ]
Rinaldi, Christopher A. [1 ]
机构
[1] Guys & St Thomas NHS Fdn Trust, Dept Cardiol, London, England
[2] Kings Coll London, Dept Imaging Sci, London, England
[3] Guys & St Thomas NHS Fdn Trust, Dept Cardiac Comp Tomog, London, England
来源
EUROPACE | 2017年 / 19卷 / 06期
关键词
Cardiac perforation diagnosis; Transthoracic echocardiography; Computed tomography; Pacemaker; Lead extraction; RIGHT-VENTRICULAR PERFORATION; REVISION;
D O I
10.1093/europace/euw074
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims Cardiac perforations caused by pacemaker or implantable cardioverter-defibrillator (ICD) leads are uncommon but potentially fatal events. The optimal approach to such cases is unclear. The aim of this study was to identify the optimal imaging modality and management strategy for cardiac perforation. Methods and results All patients presenting to a single institution with cardiac perforation >24 h since implant between 2011 and 2015 were identified retrospectively. Assessment of the diagnostic performance of pre-extraction chest radiography, transthoracic echocardiography (TTE), and computed tomography (CT) was carried out by blinded review. The method of lead extraction and any associated complications were examined. Eighteen cases of cardiac perforation were identified from 426 lead extraction procedures. Sixteen patients had abnormal electrical parameters at device interrogation. In all cases, the perforating lead was an active fixation model, and in four cases, this was an ICD coil. The accuracy of CT imaging for the diagnosis of cardiac perforation was 92.9%, with sensitivity and specificity of 100 and 85.7%, respectively. This was superior to both TTE (accuracy 62.7%, sensitivity and specificity 41.2 and 84.2%, respectively) and chest radiography (accuracy 61.1%, sensitivity and specificity 27.7 and 94.4%, respectively). Transvenous lead extraction (TLE) was performed in 17 patients, and a hybrid surgical approach in 1 patient. Of those who underwent TLE, there was 100% complete procedural success as per Heart Rhythm Society definitions. Conclusion In the setting of cardiac perforation, CT is the imaging modality of choice. Transvenous lead extraction can be recommended as a safe, efficacious, and versatile intervention.
引用
收藏
页码:1031 / 1037
页数:7
相关论文
共 50 条
  • [41] Focused Transesophageal Echocardiography for Bedside Diagnosis of Iatrogenic Cardiac Perforation: A Case Report
    Yeoh, Cindy B.
    Fischer, Gregory W.
    Tollinche, Luis E.
    A & A PRACTICE, 2019, 13 (11): : 407 - 408
  • [42] Cardiac strangulation from epicardial pacemaker leads: diagnosis, treatment, and prevention
    Takeuchi D.
    Tomizawa Y.
    General Thoracic and Cardiovascular Surgery, 2015, 63 (1) : 22 - 29
  • [43] Predictors and management of cardiac perforation caused by cardiac rhythm device implantation
    Elbatran, Ahmed I.
    Gallagher, Mark M.
    Bajpai, Abhay
    Grimster, Alexander
    Li, Anthony
    EUROPEAN HEART JOURNAL SUPPLEMENTS, 2020, 22 (0K) : K1 - K1
  • [44] Comparison between percutaneous extraction of implantable cardioverter defibrillator leads and pacemaker leads
    Klug, D.
    Marquie, C.
    Brigadeau, F.
    Guedon, L.
    Kouakam, C.
    Lacroix, D.
    Kacet, S.
    EUROPEAN HEART JOURNAL, 2008, 29 : 397 - 397
  • [45] Reducing Cardiac Tamponade Caused by Temporary Pacemaker Perforation in Transcatheter Aortic Valve Replacement
    Dalen, Magnus
    Settergren, Magnus
    Meduri, Christopher
    Ruck, Andreas
    Saleh, Nawzad
    Feldt, Kari
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2022, 80 (12) : B187 - B187
  • [46] Reducing cardiac tamponade caused by temporary pacemaker perforation in transcatheter aortic valve replacement*
    Feldt, Kari
    Dalen, Magnus
    Meduri, Christopher U.
    Kastengren, Mikael
    Bager, Jessica
    Hornsten, Jonas
    Omar, Aninda
    Ruck, Andreas
    Saleh, Nawzad
    Linder, Rickard
    Settergren, Magnus
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2023, 377 : 26 - 32
  • [47] The role of transvenous lead extraction in the management of redundant or malfunctioning pacemaker and defibrillator leads post ELECTRa
    Sidhu, Baldeep S.
    Gould, Justin
    Sieniewicz, Benjamin
    Porter, Bradley
    Rinaldi, Christopher A.
    EUROPACE, 2018, 20 (11): : 1733 - 1740
  • [48] Management of malfunctioning and recalled pacemaker and defibrillator leads: results of the European Heart Rhythm Association survey
    Bongiorni, Maria Grazia
    Dagres, Nikolaos
    Estner, Heidi
    Pison, Laurent
    Todd, Derick
    Blomstrom-Lundqvist, Carina
    EUROPACE, 2014, 16 (11): : 1674 - 1678
  • [49] Rationale for the management of pacemaker and defibrillator complications
    Byrd, C
    PRACTICE AND PROGRESS IN CARDIAC PACING AND ELECTROPHYSIOLOGY, 1996, : 239 - 248
  • [50] PERCUTANEOUS EXTRACTION OF CARDIAC PACEMAKER AND IMPLANTABLE CARDIOVERTER DEFIBRILLATOR LEADS WITH A NEW TOOL; A SINGLE CENTER EXPERIENCE
    Oto, Ali
    Aytemir, Kudret
    Kabakci, Giray
    Yorgun, Hikmet
    Canpolat, Ugur
    Kaya, Ergun Baris
    Ates, Ahmet Hakan
    Dural, Muhammet
    Sunman, Hamza
    Evranos, Banu
    Ulgen, Aysegul
    Ozkutlu, Hilmi
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2010, 140 : S83 - S83