Management of malfunctioning and recalled pacemaker and defibrillator leads: results of the European Heart Rhythm Association survey

被引:23
|
作者
Bongiorni, Maria Grazia [1 ]
Dagres, Nikolaos [2 ]
Estner, Heidi [3 ,4 ]
Pison, Laurent [5 ]
Todd, Derick [6 ]
Blomstrom-Lundqvist, Carina [7 ]
机构
[1] Univ Hospital Pisa, CardioThorac & Vasc Dept, Pisa, Italy
[2] Univ Athens, Attikon Univ Hosp, Cardiol Dept 2, Athens, Greece
[3] LMU Klinikum, Dept Cardiol Med Klin & Poliklin, Munich, Germany
[4] Univ Munich, Munich, Germany
[5] Maastricht Univ, Med Ctr, Dept Cardiol, Maastricht, Netherlands
[6] Liverpool Heart Chest Hosp, Inst Cardiovasc Med & Sci, Liverpool, Merseyside, England
[7] Uppsala Univ, Inst Med Sci, Dept Cardiol, Uppsala, Sweden
来源
EUROPACE | 2014年 / 16卷 / 11期
关键词
Cardiac implantable electronic devices; Pacemaker; Implantable Cardioverter; defibrillator; Leads; Malfunction; Recall; Extraction; Abandonment; EHRA survey; EP wire; EXTRACTION; FAILURE; SAFETY;
D O I
10.1093/europace/euu302
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The aim of this survey was to describe the different strategies regarding the management of malfunctioning and recalled pacemaker and defibrillator leads across Europe. A questionnaire has been designed to assess the current practice and physician's approach to the management of leads which are faulty, unnecessary, and/or recalled. Responses to the questionnaire were received from 34 hospitals-members of the European Heart Rhythm Association (EHRA) electrophysiology (EP) research network. The survey involved both very high and low volume implanting centres, with 85% of the responding centres performing lead extraction. The survey provides a panoramic view of operator's decision making in the field of malfunctioning, recalled, and redundant leads and outlines a common point of view on lead abandonment and factors influencing the decision about lead extraction. The main factors strongly influencing the decision making were patient's age (59%), the presence of the damaged leads (44%), and the lead dwelling time (44%). Regarding the lead abandonment, the main concern (61%) was the potential greater difficulty associated with lead extraction in the future. High volume extracting centres showed a greater propensity to removing the malfunctioning or recalled leads compared with low volume or non-extracting centres. This EP Wire survey gives a snapshot of the operators' approaches and options regarding redundant, malfunctioning, and recalled lead management and may form the basis for future prospective research on this topic.
引用
收藏
页码:1674 / 1678
页数:5
相关论文
共 50 条
  • [1] Current implantable cardioverter-defibrillator programming in Europe: the results of the European Heart Rhythm Association survey
    Proclemer, Alessandro
    Bongiorni, Maria Grazia
    Etsner, Heidi
    Todd, Derick
    Sciaraffia, Elena
    Blomstrom-Lundqvist, Carina
    EUROPACE, 2014, 16 (06): : 935 - 938
  • [2] Defibrillation testing at the time of implantable cardioverter defibrillator implantation: results of the European Heart Rhythm Association survey
    Morgan, John M.
    Marinskis, Germanas
    EUROPACE, 2011, 13 (04): : 581 - 582
  • [3] Management of patients with ventricular tachycardia in Europe: results of the European Heart Rhythm Association survey
    Chen, Jian
    Todd, Derick M.
    Proclemer, Alessandro
    Sciaraffia, Elena
    Estner, Heidi L.
    Broadhurst, Paul
    Blomstrom-Lundqvist, Carina
    EUROPACE, 2015, 17 (08): : 1294 - 1299
  • [4] Clinical management of arrhythmias in elderly patients: results of the European Heart Rhythm Association survey
    Chen, Jian
    Hocini, Meleze
    Larsen, Torben Bjerregaard
    Proclemer, Alessandro
    Sciaraffia, Elena
    Blomstrom-Lundqvist, Carina
    EUROPACE, 2015, 17 (02): : 314 - 317
  • [5] Current investigation and management of patients with syncope: results of the European Heart Rhythm Association survey
    Dagres, Nikolaos
    Bongiorni, Maria Grazia
    Dobreanu, Dan
    Madrid, Antonio
    Svendsen, Jesper Hastrup
    Blomstrom-Lundqvist, Carina
    EUROPACE, 2013, 15 (12): : 1812 - 1815
  • [6] Management of ventricular tachycardia in the ablation era: results of the European Heart Rhythm Association Survey
    Tilz, Roland Richard
    Lenarczyk, Radoslaw
    Scherr, Daniel
    Haugaa, Kristina Herman
    Iliodromitis, Konstantinos
    Puererfellner, Helmut
    Kiliszek, Marek
    Dagres, Nikolaos
    EUROPACE, 2018, 20 (01): : 209 - 213
  • [7] The role of transvenous lead extraction in the management of redundant or malfunctioning pacemaker and defibrillator leads post ELECTRa
    Sidhu, Baldeep S.
    Gould, Justin
    Sieniewicz, Benjamin
    Porter, Bradley
    Rinaldi, Christopher A.
    EUROPACE, 2018, 20 (11): : 1733 - 1740
  • [8] Translating guidelines into practice for the management of atrial fibrillation: results of an European Heart Rhythm Association Survey
    Dan, Gheorghe-Andrei
    Iliodromitis, Konstantinos
    Scherr, Daniel
    Marin, Francisco
    Lenarczyk, Radoslaw
    Estner, Heidi L.
    Kostkiewicz, Marcin
    Dagres, Nikolaos
    Lip, Gregory Y. H.
    EUROPACE, 2018, 20 (08): : 1382 - 1387
  • [9] Contemporary management of ventricular electrical storm in Europe: results of a European Heart Rhythm Association Survey
    Baldi, Enrico
    Conte, Giulio
    Zeppenfeld, Katja
    Lenarczyk, Radoslaw
    Guerra, Jose M.
    Farkowski, Michal M.
    de Asmundis, Carlo
    Boveda, Serge
    EUROPACE, 2023, 25 (04): : 1277 - 1283
  • [10] Work-up and management of lone atrial fibrillation: results of the European Heart Rhythm Association Survey
    Pison, Laurent
    Hocini, Meleze
    Potpara, Tatjana S.
    Todd, Derick
    Chen, Jian
    Blomstrom-Lundqvist, Carina
    EUROPACE, 2014, 16 (10): : 1521 - 1523