Reducing cardiac tamponade caused by temporary pacemaker perforation in transcatheter aortic valve replacement*

被引:4
|
作者
Feldt, Kari [1 ,2 ]
Dalen, Magnus [3 ,4 ]
Meduri, Christopher U. [2 ]
Kastengren, Mikael [2 ,3 ]
Bager, Jessica [2 ]
Hornsten, Jonas [2 ]
Omar, Aninda [4 ]
Ruck, Andreas [1 ,2 ]
Saleh, Nawzad [1 ,2 ]
Linder, Rickard [2 ]
Settergren, Magnus [1 ,2 ]
机构
[1] Karolinska Inst, Dept Med, SE-17176 Stockholm, Sweden
[2] Karolinska Univ Hosp, Dept Cardiol, SE-17176 Stockholm, Sweden
[3] Karolinska Inst, Dept Mol Med & Surg, SE-17176 Stockholm, Sweden
[4] Karolinska Univ Hosp, Dept Cardiothorac Surg, SE-17176 Stockholm, Sweden
关键词
TAVI; Femoral; Conduction abnormalities; Cardiac tamponade; Temporary pacing; Miscellaneous; CONDUCTION DISORDERS; OUTCOMES; IMPLANTATION; MANAGEMENT; PREDICTORS; TRENDS; TAVR;
D O I
10.1016/j.ijcard.2023.01.015
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Cardiac tamponade caused by temporary right ventricular (RV) pacemaker perforation is a rare but serious complication in transcatheter aortic valve replacement (TAVR).Aims: To study the incidence of temporary pacemaker related cardiac tamponade in TAVR, and the relation to the type of pacemaker lead used in periprocedural temporary transvenous pacing.Methods: A single center registry of transfemoral TAVRs in 2014-2020. Main inclusion criterion was perioperative use of a temporary RV pacing lead. Main exclusion criteria were a preoperatively implanted permanent pacemaker or the exclusive use of left ventricular guidewire pacing. Incident cardiac tamponade was classified as pacemaker lead related, or other. Patients were grouped according to type of temporary RV pacing wire.Results: 810 patients were included (age 80.5 +/- 7.3 [mean +/- standard deviation], female 319, 39.4%). Of these, 566 (69.9%) received a standard RV temporary pacing wire (RV-TPW), and 244 (30.1%) received temporary RV pacing through a permanent, passive pacemaker lead (RV-TPPL). In total, 18 (2.2%) events of cardiac tamponade occurred, 12 (67%) were pacemaker lead related. All pacemaker lead-related cardiac tamponades occurred in the group who received a standard RV-TPW and none in the group who received RV-TPPL (n = 12 [2.1%] vs. n = 0 [0%], p = 0.022). No difference in cardiac tamponade due to other causes was seen between the groups (p = 0.82).Conclusions: The use of soft-tip RV-TPPL was associated with a lower risk of pacemaker related cardiac tamponade in TAVR. When perioperative pacing is indicated, temporary RV-TPPL may contribute to a significant reduction of cardiac tamponade in TAVR.
引用
收藏
页码:26 / 32
页数:7
相关论文
共 50 条
  • [1] Reducing Cardiac Tamponade Caused by Temporary Pacemaker Perforation in Transcatheter Aortic Valve Replacement
    Dalen, Magnus
    Settergren, Magnus
    Meduri, Christopher
    Ruck, Andreas
    Saleh, Nawzad
    Feldt, Kari
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2022, 80 (12) : B187 - B187
  • [2] Prevention of Right Ventricular Perforation Due to Temporary Pacemaker Lead During Transcatheter Aortic Valve Replacement Reply
    Rezq, Ahmed
    Latib, Azeem
    Basavarajaiah, Sandeep
    Maisano, Francesco
    Colombo, Antonio
    JACC-CARDIOVASCULAR INTERVENTIONS, 2013, 6 (04) : 427 - 428
  • [3] Cardiac Tamponade After Transcatheter Aortic Valve Replacement Using a Transaortic Approach
    Wang, Cindy
    Hamburger, Joshua
    Bhatt, Himani
    A & A CASE REPORTS, 2014, 3 (09) : 113 - 115
  • [4] Impact of surgical aortic valve replacement volume on tamponade after transcatheter aortic valve replacement
    Agrawal, Ankit
    Shekhar, Shashank
    Isogai, Toshiaki
    Ramu, Shivabalan Kathavarayan
    Badwan, Osamah
    Yun, James J.
    Harb, Serge C.
    Krishnaswamy, Amar
    Kapadia, Samir R.
    CARDIOVASCULAR DIAGNOSIS AND THERAPY, 2024, 14 (02) : 311 - 313
  • [5] Cardiac tamponade secondary to right ventricular perforation caused by a temporary pacemaker lead in the course of myocardial infarction
    Shibutani, Hiroki
    Yutaka, Kotaro
    Mukai, Yu
    Akita, Yuzo
    Yoshinaga, Masahiro
    CARDIOLOGY JOURNAL, 2018, 25 (04) : 538 - 539
  • [6] Nonsurgical management of cardiac tamponade caused by a temporary pacemaker lead
    Trehan, V
    Mehta, V
    Mukhopadhyay, S
    Yusuf, J
    Rastogi, V
    Yaduvanshi, A
    Tyagi, S
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2005, 28 (03): : 242 - 244
  • [7] Mitral valve perforation during transcatheter aortic valve replacement
    Higa, Shotaro
    Nagano, Takaaki
    Yamashiro, Satoshi
    Iwabuchi, Masashi
    ASIAN CARDIOVASCULAR & THORACIC ANNALS, 2020, 28 (05): : 276 - 278
  • [8] Delayed cardiac tamponade by iatrogenic aortic perforation with pacemaker implantation
    Sticco, CC
    Barrett, LO
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2006, 131 (02): : 480 - 481
  • [9] Ascending aorta perforation with cardiac tamponade 19 days after transcatheter aortic valve implantation
    R. Joustra
    P. Kievit
    M. Verkroost
    H. Gehlmann
    M.-J. de Boer
    Netherlands Heart Journal, 2016, 24 : 621 - 622
  • [10] Left Ventricular Wall Rupture And Cardiac Tamponade During Transcatheter Aortic Valve Replacement
    Agrawal, Y.
    Kalavakunta, J.
    Saltiel, F.
    Gupta, V.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2016, 193