Ruggedness and other performance characteristics of low-pressure gas chromatography-mass spectrometry for the fast analysis of multiple pesticide residues in food crops

被引:56
|
作者
Mastovska, K
Hajslová, J
Lehotay, SJ
机构
[1] USDA ARS, Eastern Reg Res Ctr, Wyndmoor, PA 19038 USA
[2] Inst Chem Technol, CR-16628 Prague 6, Czech Republic
关键词
pesticide residue analysis; ruggedness; matrix effects; injection volume; food analysis;
D O I
10.1016/j.chroma.2004.08.061
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Low-pressure gas chromatography-mass spectrometry (LP-GC-MS) using a quadrupole MS instrument was further optimized and evaluated for the fast analysis of multiple pesticide residues in food crops. Performance of two different LP-GC-MS column configurations was compared in various experiments, including ruggedness tests with repeated injections of pesticides in matrix extracts. The tested column configurations employed the same 3 m x 0.15 mm i.d. restriction capillary at the inlet end, but different analytical columns attached to the vacuum: (A) a 10 in x 0.53 min i.d., 1 mum film thickness RTX-5 Sil MS column; and (B) a 10 m x 0.25 mm i.d., 0.25 mum film thickness DB-5MS column. Under the optimized conditions (compromise between speed and sensitivity), the narrower analytical column with a thinner film provided slightly (<1.1-fold) faster analysis of <5.5 min separation times and somewhat greater separation efficiency. However, lower detection limits for most of the tested pesticides in real extracts were achieved using the mega-bore configuration, which also provided significantly greater ruggedness of the analysis (long-term repeatability of analyte peak intensities, shapes, and retention times). Additionally, the effect of the increasing injection volume (1-5 mul) on analyte signal-to-noise ratios was evaluated. For the majority of the tested analyte-matrix combinations, the increase in sensitivity caused by a larger injection did not translate in the same gain in analyte delectability. Considering the costs and benefits, the injection volume of 2-3 mul was optimal for delectability of the majority of 57 selected pesticides in apple, carrot, lettuce, and wheat extracts. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:335 / 349
页数:15
相关论文
共 50 条
  • [41] Microextraction technique associated with gas chromatography-mass spectrometry for determining pesticide residues in urine
    Silva, Thais L. R.
    de Queiroz, Maria Eliana L. R.
    de Oliveira, Andre Fernando
    Rodrigues, Alessandra A. Z.
    Neves, Antonio Augusto
    Vieira, Patricia A. F.
    de Queiroz, Jose Humberto
    Barbosa, Veronica O. de P.
    JOURNAL OF ENVIRONMENTAL SCIENCE AND HEALTH PART B-PESTICIDES FOOD CONTAMINANTS AND AGRICULTURAL WASTES, 2022, 57 (03) : 165 - 175
  • [42] Simultaneous determination of 118 pesticide residues in Chinese teas by gas chromatography-mass spectrometry
    Yang, Xin
    Xu, De Chang
    Qiu, Jian Wei
    Zhang, Hua
    Zhang, Ying Chun
    Dong, Ai Jun
    Ma, Ying
    Wang, Jing
    CHEMICAL PAPERS, 2009, 63 (01): : 39 - 46
  • [43] Simultaneous determination of 102 pesticide residues in Chinese teas by gas chromatography-mass spectrometry
    Huang, Zhiqiang
    Li, Yongjun
    Chen, Bo
    Yao, Shouzhuo
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2007, 853 (1-2): : 154 - 162
  • [44] Comparison of sample preparation methods combined with fast gas chromatography -: mass spectrometry for ultratrace analysis of pesticide residues in baby food
    Hercegova, Andrea
    Domotorova, Milena
    Kruzlicova, Dasa
    Matisova, Eva
    JOURNAL OF SEPARATION SCIENCE, 2006, 29 (08) : 1102 - 1109
  • [45] Comparison of Simple and Rapid Extraction Procedures for the Determination of Pesticide Residues in Fruit Juices by Fast Gas Chromatography-Mass Spectrometry
    Cherta, Laura
    Beltran, Joaquim
    Pitarch, Elena
    Hernandez, Felix
    FOOD ANALYTICAL METHODS, 2013, 6 (06) : 1671 - 1684
  • [46] Determination of 33 Pesticide Residues in Honeysuckle by Gel Permeation Chromatography Purification and Gas Chromatography-Mass Spectrometry
    Zhuang Wan-E
    Gong Zhen-Bin
    Ye Jiang-Lei
    Chen Deng-Yun
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2010, 38 (06) : 811 - 816
  • [47] Determination of organochlorine pesticide residues in food by polystyrene coated silica magnetic microspheres combined with gas chromatography-mass spectrometry
    Wang, Jinxin
    Shi, Yilan
    Pan, Yuping
    Qiu, Qianying
    Ye, Qinghua
    Cheng, Xiaohong
    Yang, Qinghua
    Yu, Chunmei
    MICROCHEMICAL JOURNAL, 2024, 207
  • [48] Identification of individuals by gas chromatography-mass spectrometry analysis of fingerprint residues
    Kuhns, Teresa
    Zentz, Stephanie
    Thomas, Robert
    Sarago, Kaitlin
    Saffle, Justin
    Akers, Melissa
    Egolf, Debra
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2017, 253
  • [49] Selective extraction and determination of multiclass pesticide residues in post-harvest french beans by low-pressure gas chromatography/tandem mass spectrometry
    Vidal, JLM
    González-Rodríguez, J
    Arrebola, FJ
    Frenich, AG
    López, FJS
    Díez, NM
    JOURNAL OF AOAC INTERNATIONAL, 2003, 86 (04) : 856 - 867