Ruggedness and other performance characteristics of low-pressure gas chromatography-mass spectrometry for the fast analysis of multiple pesticide residues in food crops

被引:56
|
作者
Mastovska, K
Hajslová, J
Lehotay, SJ
机构
[1] USDA ARS, Eastern Reg Res Ctr, Wyndmoor, PA 19038 USA
[2] Inst Chem Technol, CR-16628 Prague 6, Czech Republic
关键词
pesticide residue analysis; ruggedness; matrix effects; injection volume; food analysis;
D O I
10.1016/j.chroma.2004.08.061
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Low-pressure gas chromatography-mass spectrometry (LP-GC-MS) using a quadrupole MS instrument was further optimized and evaluated for the fast analysis of multiple pesticide residues in food crops. Performance of two different LP-GC-MS column configurations was compared in various experiments, including ruggedness tests with repeated injections of pesticides in matrix extracts. The tested column configurations employed the same 3 m x 0.15 mm i.d. restriction capillary at the inlet end, but different analytical columns attached to the vacuum: (A) a 10 in x 0.53 min i.d., 1 mum film thickness RTX-5 Sil MS column; and (B) a 10 m x 0.25 mm i.d., 0.25 mum film thickness DB-5MS column. Under the optimized conditions (compromise between speed and sensitivity), the narrower analytical column with a thinner film provided slightly (<1.1-fold) faster analysis of <5.5 min separation times and somewhat greater separation efficiency. However, lower detection limits for most of the tested pesticides in real extracts were achieved using the mega-bore configuration, which also provided significantly greater ruggedness of the analysis (long-term repeatability of analyte peak intensities, shapes, and retention times). Additionally, the effect of the increasing injection volume (1-5 mul) on analyte signal-to-noise ratios was evaluated. For the majority of the tested analyte-matrix combinations, the increase in sensitivity caused by a larger injection did not translate in the same gain in analyte delectability. Considering the costs and benefits, the injection volume of 2-3 mul was optimal for delectability of the majority of 57 selected pesticides in apple, carrot, lettuce, and wheat extracts. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:335 / 349
页数:15
相关论文
共 50 条
  • [21] Fast and sensitive determination of pesticide residues in vegetables using low-pressure gas chromatography with a triple quadrupole mass spectrometer
    Walorczyk, Stanislaw
    Gnusowski, Boguslaw
    JOURNAL OF CHROMATOGRAPHY A, 2006, 1128 (1-2) : 236 - 243
  • [22] Control of pesticide residues by liquid chromatography-mass spectrometry to ensure food safety
    Pico, Yolanda
    Font, Guillermina
    Ruiz, Maria Jose
    Fernandez, Monica
    MASS SPECTROMETRY REVIEWS, 2006, 25 (06) : 917 - 960
  • [23] Fast analysis of multiple pesticide residues in apple juice using dispersive liquid-liquid microextraction and multidimensional gas chromatography-mass spectrometry
    Cunha, S. C.
    Fernandes, J. O.
    Oliveira, M. B. P. P.
    JOURNAL OF CHROMATOGRAPHY A, 2009, 1216 (51) : 8835 - 8844
  • [24] Fast temperature-programmed gas chromatography-mass spectrometry for food analysis
    Lloyd, SW
    Grimm, CC
    JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2002, 40 (06) : 309 - 314
  • [25] Simultaneous Determination of 70 Pesticide Residues in Coffees by Gas Chromatography-Mass Spectrometry
    Yang, Xin
    Wang, Jing
    Zhang, Hua
    Xu, Dechang
    Qiu, Jianwei
    Wang, ZhenYu
    Cao, WeiQiang
    2010 4TH INTERNATIONAL CONFERENCE ON BIOINFORMATICS AND BIOMEDICAL ENGINEERING (ICBBE 2010), 2010,
  • [26] Evaluation of the QuEChERS Method and Gas Chromatography-Mass Spectrometry for the Analysis Pesticide Residues in Water and Sediment
    Brondi, S. H. G.
    de Macedo, A. N.
    Vicente, G. H. L.
    Nogueira, A. R. A.
    BULLETIN OF ENVIRONMENTAL CONTAMINATION AND TOXICOLOGY, 2011, 86 (01) : 18 - 22
  • [27] Determination of 193 pesticide residues in vegetables and fruits by gas chromatography-mass spectrometry
    Cui Shuhua
    Chen Weishuang
    Qian Jialiang
    Duan Hao
    Liu Tongying
    Zhang Lidong
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2013, 31 (09) : 885 - 893
  • [28] Simultaneous Determination of 69 Pesticide Residues in Coffee by Gas Chromatography-Mass Spectrometry
    Yang, Xin
    Wang, Jing
    Xu, D. C.
    Qiu, J. W.
    Ma, Ying
    Cui, J.
    FOOD ANALYTICAL METHODS, 2011, 4 (02) : 186 - 195
  • [29] Field gas chromatography-mass spectrometry for fast analysis
    Makas, AL
    Troshkov, ML
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2004, 800 (1-2): : 55 - 61
  • [30] Determination of Strobilurin Fungicide Residues in Food by Gas Chromatography-Mass Spectrometry
    Bo Hai-Bo
    Wang Jin-Hua
    Guo Chun-Hui
    Qin Rong
    Lu Xiao-Yu
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2008, 36 (11) : 1471 - 1475