Model and Parameter Identification of Friction during Robotic Insertion of Cochlear-Implant Electrode Arrays

被引:0
|
作者
Zhang, Jian [1 ]
Bhattacharyya, Samrat [1 ]
Simaan, Nabil [1 ]
机构
[1] Columbia Univ, Dept Mech Engn, New York, NY 10027 USA
关键词
STRAIGHT;
D O I
暂无
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Robot-assisted cochlear implant surgery was proposed and proved to be efficient in reducing insertion forces on acrylic scala tympani models. During experiments, the authors discovered that the insertion force not only depends on the shape discrepancy between the scala tympani and the inserted electrode array, but also on the insertion speed. This paper presents a friction model that describes the whole insertion process and investigates the relationship between the insertion speed and the insertion force. Experimental and statistical results show the effectiveness of the model. Applying the friction model generates safety insertion force boundaries for future insertions and gives the optimal insertion speed. It also provides predictive force information for insertion speed feedback control law design which may be applied to robot-assisted cochlear implant surgeries.
引用
收藏
页码:3528 / 3533
页数:6
相关论文
共 50 条
  • [41] Modelling and Optimization of the Insertion of a Preformed Cochlear Implant Electrode Array
    Rau, Th S.
    Lenarz, Th
    Majdani, O.
    BIOMEDICAL ENGINEERING-BIOMEDIZINISCHE TECHNIK, 2014, 59 : S1080 - +
  • [42] Development of Insertion Models Predicting Cochlear Implant Electrode Position
    van der Marel, Kim S.
    Briaire, Jeroen J.
    Wolterbeek, Ron
    Verbist, Berit M.
    Frijns, Johan H. M.
    EAR AND HEARING, 2016, 37 (04): : 473 - 482
  • [43] Cochlear implant deep electrode insertion: Extent of insertional trauma
    Gstoettner, W
    Plenk, H
    Franz, P
    Hamzavi, J
    Baumgartner, W
    Czerny, C
    Ehrenberger, K
    ACTA OTO-LARYNGOLOGICA, 1997, 117 (02) : 274 - 277
  • [44] Insertion trauma of a cochlear implant electrode array with Nitinol inlay
    Thomas S. Rau
    Lenka Harbach
    Nick Pawsey
    Marcel Kluge
    Peter Erfurt
    Thomas Lenarz
    Omid Majdani
    European Archives of Oto-Rhino-Laryngology, 2016, 273 : 3573 - 3585
  • [45] The Effect of Different Lubricants on Cochlear Implant Electrode Insertion Forces
    Kontorinis, Georgios
    Paasche, Gerrit
    Lenarz, Thomas
    Stoever, Timo
    OTOLOGY & NEUROTOLOGY, 2011, 32 (07) : 1050 - 1056
  • [46] Lateralization of Interaural Level Differences with Multiple Electrode Stimulation in Bilateral Cochlear-Implant Listeners
    Stakhovskaya, Olga A.
    Goupell, Matthew J.
    EAR AND HEARING, 2017, 38 (01): : E22 - E38
  • [47] Automatic Cochlear Duct Length Estimation for Selection of Cochlear Implant Electrode Arrays
    Rivas, Alejandro
    Cakir, Ahmet
    Hunter, Jacob B.
    Labadie, Robert F.
    Zuniga, M. Geraldine
    Wanna, George B.
    Dawant, Benoit M.
    Noble, Jack H.
    OTOLOGY & NEUROTOLOGY, 2017, 38 (03) : 339 - 346
  • [48] Comodulation masking release in speech identification with real and simulated cochlear-implant hearing
    Ihlefeld, Antje
    Shinn-Cunningham, Barbara G.
    Carlyon, Robert P.
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2012, 131 (02): : 1315 - 1324
  • [49] Psychoacoustic and Phoneme Identification Measures in Cochlear-Implant and Normal-Hearing Listeners
    Goldsworthy, Ray L.
    Delhorne, Lorraine A.
    Braida, Louis D.
    Reed, Charlotte M.
    TRENDS IN AMPLIFICATION, 2013, 17 (01): : 27 - 44
  • [50] Cochlear Size Assessment Predicts Scala Tympani Volume and Electrode Insertion Force- Implications in Robotic Assisted Cochlear Implant Surgery
    Dhanasingh, Anandhan
    Swords, Chloe
    Bance, Manohar
    Van Rompaey, Vincent
    Van de Heyning, Paul
    FRONTIERS IN SURGERY, 2021, 8