Model and Parameter Identification of Friction during Robotic Insertion of Cochlear-Implant Electrode Arrays

被引:0
|
作者
Zhang, Jian [1 ]
Bhattacharyya, Samrat [1 ]
Simaan, Nabil [1 ]
机构
[1] Columbia Univ, Dept Mech Engn, New York, NY 10027 USA
关键词
STRAIGHT;
D O I
暂无
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Robot-assisted cochlear implant surgery was proposed and proved to be efficient in reducing insertion forces on acrylic scala tympani models. During experiments, the authors discovered that the insertion force not only depends on the shape discrepancy between the scala tympani and the inserted electrode array, but also on the insertion speed. This paper presents a friction model that describes the whole insertion process and investigates the relationship between the insertion speed and the insertion force. Experimental and statistical results show the effectiveness of the model. Applying the friction model generates safety insertion force boundaries for future insertions and gives the optimal insertion speed. It also provides predictive force information for insertion speed feedback control law design which may be applied to robot-assisted cochlear implant surgeries.
引用
收藏
页码:3528 / 3533
页数:6
相关论文
共 50 条
  • [21] Considerations for design of future cochlear implant electrode arrays: Electrode array stiffness, size, and depth of insertion
    Rebscher, Stephen J.
    Hetherington, Alexander
    Bonham, Ben
    Wardrop, Peter
    Whinney, David
    Leake, Patricia A.
    JOURNAL OF REHABILITATION RESEARCH AND DEVELOPMENT, 2008, 45 (05): : 731 - 747
  • [22] Nomenclature of cochlear implant electrode insertion approaches
    Todt, Ingo
    OTOLARYNGOLOGY-HEAD AND NECK SURGERY, 2008, 138 (06) : 813 - 813
  • [23] Simulation for Training Cochlear Implant Electrode Insertion
    Ma, Xingjun
    Wijewickrema, Sudanthi
    Zhou, Yun
    Copson, Bridget
    Bailey, James
    Kennedy, Gregor
    O'Leary, Stephen
    2017 IEEE 30TH INTERNATIONAL SYMPOSIUM ON COMPUTER-BASED MEDICAL SYSTEMS (CBMS), 2017, : 1 - 6
  • [24] Auditory cortical images of cochlear-implant stimuli: Dependence on electrode configuration
    Bierer, JA
    Middlebrooks, JC
    JOURNAL OF NEUROPHYSIOLOGY, 2002, 87 (01) : 478 - 492
  • [25] MRI-Based Estimation of Scalar Cochlear-Implant Electrode Position
    Stratmann, A.
    Mittmann, P.
    Rademacher, G.
    Grupe, G.
    Hoffmann, S.
    Mutze, S.
    Ernst, A.
    Todt, I.
    BIOMED RESEARCH INTERNATIONAL, 2017, 2017
  • [26] Surface patterning of cochlear implant electrode arrays
    Fadeeva, E.
    Linke, I
    Lenarz, T.
    Chichkov, B.
    Paasche, G.
    BIOMEDICAL ENGINEERING-BIOMEDIZINISCHE TECHNIK, 2013, 58
  • [27] Automatic Identification of Cochlear Implant Electrode Arrays for Post-Operative Assessment
    Noble, Jack H.
    Schuman, Theodore A.
    Wright, Charles G.
    Labadie, Robert F.
    Dawant, Benoit M.
    MEDICAL IMAGING 2011: IMAGE PROCESSING, 2011, 7962
  • [28] Preclinical evaluation of a hydraulic actuation system with guide tube for robotic cochlear implant electrode insertion
    Cramer, Jakob
    Salcher, Rolf
    Froehlich, Max
    Boettcher-Rebmann, Georg
    Artukarslan, Eralp
    Lenarz, Thomas
    Rau, Thomas S.
    BIOMEDICAL ENGINEERING ONLINE, 2025, 24 (01)
  • [29] Preoperative angular insertion depth prediction in case of lateral wall cochlear implant electrode arrays
    Khan, Mohammad M. R.
    Labadie, Robert F.
    Noble, Jack H.
    MEDICAL IMAGING 2020: IMAGE-GUIDED PROCEDURES, ROBOTIC INTERVENTIONS, AND MODELING, 2021, 11315
  • [30] Measurement and Mitigation of Intracochlear Pressure Transients During Cochlear Implant Electrode Insertion
    Hartl, Renee M. Banakis
    Greene, Nathaniel T.
    OTOLOGY & NEUROTOLOGY, 2022, 43 (02) : 174 - 182