Model and Parameter Identification of Friction during Robotic Insertion of Cochlear-Implant Electrode Arrays

被引:0
|
作者
Zhang, Jian [1 ]
Bhattacharyya, Samrat [1 ]
Simaan, Nabil [1 ]
机构
[1] Columbia Univ, Dept Mech Engn, New York, NY 10027 USA
关键词
STRAIGHT;
D O I
暂无
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Robot-assisted cochlear implant surgery was proposed and proved to be efficient in reducing insertion forces on acrylic scala tympani models. During experiments, the authors discovered that the insertion force not only depends on the shape discrepancy between the scala tympani and the inserted electrode array, but also on the insertion speed. This paper presents a friction model that describes the whole insertion process and investigates the relationship between the insertion speed and the insertion force. Experimental and statistical results show the effectiveness of the model. Applying the friction model generates safety insertion force boundaries for future insertions and gives the optimal insertion speed. It also provides predictive force information for insertion speed feedback control law design which may be applied to robot-assisted cochlear implant surgeries.
引用
收藏
页码:3528 / 3533
页数:6
相关论文
共 50 条
  • [31] Robotic pullback technique of a precurved cochlear-implant electrode array using real-time impedance sensing feedback
    Riojas, Katherine E.
    Bruns, Trevor L.
    Granna, Josephine
    Webster, Robert J., III
    Labadie, Robert F.
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2023, 18 (03) : 413 - 421
  • [32] Robotic pullback technique of a precurved cochlear-implant electrode array using real-time impedance sensing feedback
    Katherine E. Riojas
    Trevor L. Bruns
    Josephine Granna
    Robert J. Webster
    Robert F. Labadie
    International Journal of Computer Assisted Radiology and Surgery, 2023, 18 : 413 - 421
  • [33] Implications of Deep Electrode Insertion on Cochlear Implant Fitting
    Mathieu Gani
    Gregory Valentini
    Alain Sigrist
    Maria-Izabel Kós
    Colette Boëx
    Journal of the Association for Research in Otolaryngology, 2007, 8 : 69 - 83
  • [34] Cochlear implant electrode insertion: The round window revisited
    Roland, Peter S.
    Wright, Charles G.
    Isaacson, Brandon
    LARYNGOSCOPE, 2007, 117 (08): : 1397 - 1402
  • [35] Implications of deep electrode insertion on cochlear implant fitting
    Gani, Mathieu
    Valentini, Gregory
    Sigrist, Alain
    Kos, Maria-Izabel
    Boex, Colette
    JARO-JOURNAL OF THE ASSOCIATION FOR RESEARCH IN OTOLARYNGOLOGY, 2007, 8 (01): : 69 - 83
  • [36] Atraumaticity Study of 2 Cochlear Implant Electrode Arrays
    Manrique, Manuel
    Picciafuoco, Sebastian
    Manrique, Raquel
    Sanhueza, Ignacio
    Dominguez, Pablo
    Perez, Nicolas
    Luis Zubieta, Jose
    de Abajo, Jorge
    OTOLOGY & NEUROTOLOGY, 2014, 35 (04) : 619 - 628
  • [38] Friction Force Measurement During Cochlear Implant Insertion: Application to a Force-Controlled Insertion Tool Design
    Miroir, Mathieu
    Nguyen, Yann
    Kazmitcheff, Guillaume
    Ferrary, Evelyne
    Sterkers, Olivier
    Grayeli, Alexis Bozorg
    OTOLOGY & NEUROTOLOGY, 2012, 33 (06) : 1092 - 1100
  • [39] Magnetic Steering of Robotically Inserted Lateral-wall Cochlear-implant Electrode Arrays Reduces Forces on the Basilar Membrane In Vitro
    Hendricks, Cameron M.
    Cavilla, Matt S.
    Usevitch, David E.
    Bruns, Trevor L.
    Riojas, Katherine E.
    Leon, Lisandro
    Webster, Robert J., III
    Warren, Frank M.
    Abbott, Jake J.
    OTOLOGY & NEUROTOLOGY, 2021, 42 (07) : 1022 - 1030
  • [40] Insertion trauma of a cochlear implant electrode array with Nitinol inlay
    Rau, Thomas S.
    Harbach, Lenka
    Pawsey, Nick
    Kluge, Marcel
    Erfurt, Peter
    Lenarz, Thomas
    Majdani, Omid
    EUROPEAN ARCHIVES OF OTO-RHINO-LARYNGOLOGY, 2016, 273 (11) : 3573 - 3585