Clinical implementation and initial experience with calypso 4D tracking system for prostate cancer treatment

被引:0
|
作者
Cao, D. [1 ]
Ye, J. [1 ]
Afghan, M. [1 ]
Wong, T. [1 ]
Shepard, D. [1 ]
机构
[1] Swedish Med Ctr, Swedish Canc Inst, Seattle, WA USA
关键词
D O I
10.1118/1.2760540
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The Calypso 4D tracking system can detect real‐time intra‐fractional tumor motion based on RF signals from the implanted beacons. The initial clinical experience on tracking prostate motion during the treatment is reported. We performed a series of tests to evaluate the calibration accuracy and stability of the system. Material and Methods: The first FDA approved clinical Calypso 4D tracking system was installed and used for this work. With three beacons implemented in the prostate, the system reports the target location in a real time fashion. Seven patients with prostate cancer were localized/tracked using this system. The vender provided a monthly calibration phantom and an in‐house developed stereotactic cone based alignment tool that were used to test the calibration accuracy of the Calypso 4D tracking system. The system stability was also studied using the monthly calibration phantom. Results: For the seven patients treated so far, the average initial setup shifts from the external tattoos were 1.1, 2.2 and 4.0 mm along lateral, longitudinal and vertical directions, respectively. For one patient, the observed maximum shifts along the above three axes were 4.6, 10.9 and 29.2 mm. The range of target motion during treatment was found to be 3.4 (Right‐Left), 9.9 (Superior‐Inferior) and 12.3 (Anterior‐Posterior) mm. The average patient setup time was less then 5 minutes. The daily QA of the system takes around 5 minutes on average. The vender provided system calibration procedure is based on room lasers with 2 mm error tolerance, which may potentially decrease the overall system accuracy. Our stereotactic cone based alignment tool can achieve sub‐millimeter accuracy. Repeated monthly calibration procedures showed that the system stability is within 1 mm. Conclusion: Calypso system provides efficient and accurate patient setup for prostate treatment. The current calibration procedure can be improved to achieve better accuracy. © 2007, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:2376 / 2376
页数:1
相关论文
共 50 条
  • [41] A new 4D Memristor chaotic system: Analysis and implementation
    Messadi, Manal
    Kemih, Karim
    Moysis, Lazaros
    Volos, Christos
    INTEGRATION-THE VLSI JOURNAL, 2023, 88 : 91 - 100
  • [42] Initial Experience with the 4D Mini-TEE Probe in the Adult Population
    Papadopoulos, Konstantinos
    Ikonomidis, Ignatios
    Coisne, Augustin
    Kayhan, Ozge Ozden
    Tzikas, Apostolos
    Fragakis, Nikolaos
    Antoniadis, Antonios P.
    Vannan, Mani A.
    Donal, Erwan
    JOURNAL OF CLINICAL MEDICINE, 2024, 13 (21)
  • [43] A Phase II Trial of Real-time Target Tracking SBRT for Low-Risk Prostate Cancer Utilizing the Calypso 4D Localization System: Patient Reported Health-related Quality of Life and Toxicity Outcomes
    Mantz, C. A.
    Fernandez, E.
    Zucker, I.
    Harrison, S.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 78 (03): : S57 - S58
  • [44] Rapid Automated Target Segmentation and Tracking on 4D Data without Initial Contours
    Chebrolu, Venkata V.
    Saenz, Daniel
    Tewatia, Dinesh
    Sethares, William A.
    Cannon, George
    Paliwal, Bhudatt R.
    RADIOLOGY RESEARCH AND PRACTICE, 2014, 2014
  • [45] Phosphodiesterase 4D (PDE4D) as a new drug target for prostate cancer
    Hammer, Kimberly D. P.
    Domenech, Maribella
    Beebe, David
    Marker, Paul C.
    CANCER RESEARCH, 2011, 71
  • [46] A clinical 3D/4D CBCT-based treatment dose monitoring system
    Qin, An
    Gersten, David
    Liang, Jian
    Liu, Qiang
    Grill, Inga
    Guerrero, Thomas
    Stevens, Craig
    Yan, Di
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2018, 19 (06): : 166 - 176
  • [47] 4D Imaging, Planning and Treatment with Cyberknife System
    Lo, A.
    Hancock, S.
    MEDICAL PHYSICS, 2008, 35 (06)
  • [48] Evaluation of Tracking Versus Conventional Delivery for Lung Cancer Radiotherapy Via 4D Treatment Planning
    Roland, Teboh
    Shi, C.
    Liu, Yaxi
    Mavroidis, P.
    Papanikolaou, N.
    MEDICAL PHYSICS, 2009, 36 (06) : 2502 - +
  • [49] A Formulation of 4D Treatment Planning for Tumour Tracking Volumetric Modulated Arc Therapy for Lung Cancer
    Cheung, Michael L. M.
    Lee, Louis K. Y.
    Chan, Anthony T. C.
    MEDICAL PHYSICS, 2015, 42 (06) : 3645 - 3645
  • [50] Segmentation and tracking system for 4D cardiac tagged MR images
    Metaxas, Dimitris N.
    Axel, Leon
    Qian, Zhen
    Huang, Xiaolei
    2006 28TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-15, 2006, : 6381 - +